• Browse all
Angular dependence of the pp elastic scattering spin correlation parameter ann-00 between 0.8-GeV and 2.8-GeV. 2. Results for higher energies

Phys.Rev.C 64 (2001) 034003, 2001.

Abstract (data abstract)
SACLAY-SATURNE-II. Measurements of the PP elastic scattering spin correlation parameter (CNN) at 18 beam kinetic energies from 1975 to 2795 MeV and at 795 MeV. The data are from the last two run periods (III and IV) of the Saturne-II accelerator in Saclay and use a vertically polarized proton beam incident on a frozen-spin, vertically polarized proton target.

  • Table 1

    Data from T 1,F 4

    10.17182/hepdata.25291.v1/t1

    Measured values of CNN at EKIN 795 Mev.. Fractional systematic uncertainty in the absolute beam and target polarization is +-0.032.

  • Table 2

    Data from T 1,F 1

    10.17182/hepdata.25291.v1/t2

    Measured values of CNN at EKIN 1975 Mev.. Fractional systematic uncertainty in the absolute beam and target polarization is +-0.052.

  • Table 3

    Data from T 1

    10.17182/hepdata.25291.v1/t3

    Measured values of CNN at EKIN 2035 Mev (from run period III).. Fractional systematic uncertainty in the absolute beam and...

  • Table 4

    Data from T 1

    10.17182/hepdata.25291.v1/t4

    Measured values of CNN at EKIN 2035 Mev (from run period IV).. Fractional systematic uncertainty in the absolute beam and...

  • Table 5

    Data from T 1,F 1

    10.17182/hepdata.25291.v1/t5

    Measured values of CNN at EKIN 2115 Mev.. Fractional systematic uncertainty in the absolute beam and target polarization is +-0.046.

  • Table 6

    Data from T 1

    10.17182/hepdata.25291.v1/t6

    Measured values of CNN at EKIN 2155 Mev.. Fractional systematic uncertainty in the absolute beam and target polarization is +-0.039.

  • Table 7

    Data from T 1,F 1

    10.17182/hepdata.25291.v1/t7

    Measured values of CNN at EKIN 2175 Mev.. Fractional systematic uncertainty in the absolute beam and target polarization is +-0.041.

  • Table 8

    Data from T 1,F 1

    10.17182/hepdata.25291.v1/t8

    Measured values of CNN at EKIN 2215 Mev.. Fractional systematic uncertainty in the absolute beam and target polarization is +-0.038.

  • Table 9

    Data from T 1,F 2

    10.17182/hepdata.25291.v1/t9

    Measured values of CNN at EKIN 2225 Mev.. Fractional systematic uncertainty in the absolute beam and target polarization is +-0.049.

  • Table 10

    Data from T 1,F 2

    10.17182/hepdata.25291.v1/t10

    Measured values of CNN at EKIN 2235 Mev.. Fractional systematic uncertainty in the absolute beam and target polarization is +-0.043.

  • Table 11

    Data from T 1,F 2

    10.17182/hepdata.25291.v1/t11

    Measured values of CNN at EKIN 2245 Mev.. Fractional systematic uncertainty in the absolute beam and target polarization is +-0.048.

  • Table 12

    Data from T 1,F 2

    10.17182/hepdata.25291.v1/t12

    Measured values of CNN at EKIN 2395 Mev.. Fractional systematic uncertainty in the absolute beam and target polarization is +-0.047.

  • Table 13

    Data from T 1,F 3

    10.17182/hepdata.25291.v1/t13

    Measured values of CNN at EKIN 2445 Mev.. Fractional systematic uncertainty in the absolute beam and target polarization is +-0.049.

  • Table 14

    Data from T 1

    10.17182/hepdata.25291.v1/t14

    Measured values of CNN at EKIN 2495 Mev.. Fractional systematic uncertainty in the absolute beam and target polarization is +-0.043.

  • Table 15

    Data from T 1,F 3

    10.17182/hepdata.25291.v1/t15

    Measured values of CNN at EKIN 2515 Mev.. Fractional systematic uncertainty in the absolute beam and target polarization is +-0.044.

  • Table 16

    Data from T 1

    10.17182/hepdata.25291.v1/t16

    Measured values of CNN at EKIN 2565 Mev.. Fractional systematic uncertainty in the absolute beam and target polarization is +-0.044.

  • Table 17

    Data from T 1

    10.17182/hepdata.25291.v1/t17

    Measured values of CNN at EKIN 2575 Mev.. Fractional systematic uncertainty in the absolute beam and target polarization is +-0.044.

  • Table 18

    Data from T 1

    10.17182/hepdata.25291.v1/t18

    Measured values of CNN at EKIN 2595 Mev.. Fractional systematic uncertainty in the absolute beam and target polarization is +-0.042.

  • Table 19

    Data from T 1,F 3

    10.17182/hepdata.25291.v1/t19

    Measured values of CNN at EKIN 2645 Mev.. Fractional systematic uncertainty in the absolute beam and target polarization is +-0.043.

  • Table 20

    Data from T 1,F 3

    10.17182/hepdata.25291.v1/t20

    Measured values of CNN at EKIN 2795 Mev.. Fractional systematic uncertainty in the absolute beam and target polarization is +-0.066.

Loading Data...

Ask a Question


Your question will be emailed to those involved with the submission. Please mention the relevant table.


Please log in to HEPData to send a question.