Measurement of the running of the fine structure constant

The L3 collaboration Acciarri, M. ; Achard, P. ; Adriani, O. ; et al.
Phys.Lett.B 476 (2000) 40-48, 2000.
Inspire Record 523920 DOI 10.17182/hepdata.50032

Bhabha scattering data recorded at \sqrt{s}=189 GeV by the L3 detector at LEP are used to measure the running of the effective fine-structure constant for spacelike momentum transfers. The results are alpha^-1(-2.1 GeV^2) - alpha^-1(-6.25 GeV^2) = 0.78 +/- 0.26 alpha^-1(-12.25 GeV^2) - alpha^-1(-3434 GeV^2) = 3.80 +/- 1.29, in agreement with theoretical predictions.

3 data tables

No description provided.

Results extracted from the small angle Bhabha scattering sample at Z peak. Results contained total experimental uncertainty.

Results extracted from the large angle Bhabha scattering sample at sqrt(s) = 189 GeV. Results contained total experimental and theoretical uncertainty.