Measurement of the direct photon spectrum in Upsilon(1S) decays.

The CLEO collaboration Nemati, B. ; Richichi, S.J. ; Ross, W.R. ; et al.
Phys.Rev.D 55 (1997) 5273-5281, 1997.
Inspire Record 425927 DOI 10.17182/hepdata.52340

Using data taken with the CLEO II detector at the Cornell Electron Storage Ring, we have determined the ratio of branching fractions: $R_{\gamma} \equiv \Gamma(\Upsilon(1S) \rightarrow \gamma gg)/\Gamma(\Upsilon(1S) \rightarrow ggg) = (2.75 \pm 0.04(stat.) \pm 0.15(syst.))%$. From this ratio, we have determined the QCD scale parameter $\Lambda_{\overline{MS}}$ (defined in the modified minimal subtraction scheme) to be $\Lambda_{\overline{MS}}= 233 \pm 11 \pm 59$ MeV, from which we determine a value for the strong coupling constant $\alpha_{s}(M_{\Upsilon(1S)}) = 0.163 \pm 0.002 \pm 0.014$, or $\alpha_{s}(M_{Z}) = 0.110 \pm 0.001 \pm 0.007$.

1 data table

The ALPHAS at MZ is extrapolation from M(UPSI).


Precision Measurement of the Total Cross-section for $e^+ e^- \to$ Hadrons at a Center-of-mass Energy of 29-{GeV}

Fernandez, E. ; Ford, William T. ; Qi, N. ; et al.
Phys.Rev.D 31 (1985) 1537, 1985.
Inspire Record 206052 DOI 10.17182/hepdata.4048

We report a high-precision measurement of the ratio R of the total cross section for e+e−→hadrons to that for e+e−→μ+μ−, at a center-of-mass energy of 29.0 GeV using the MAC detector. The result is R=3.96±0.09. This value of R is used to determine a value of the strong coupling constant αs of 0.23±0.06, nearly independent of fragmentation models. Two different analysis methods having quite different event-selection criteria have been used and the results are in agreement. Particular attention has been given to the study of systematic errors. New higher-order QED calculations are used for the luminosity determination and the acceptance for hadrons.

2 data tables

No description provided.

No description provided.


Measurement of the Branching Ratio for $\Upsilon^\prime$-prime $\to \mu \mu$

Kaarsberg, T. ; Lee-Franzini, Juliet ; Lovelock, D.M.J. ; et al.
Phys.Rev.D 35 (1987) 2265, 1987.
Inspire Record 230842 DOI 10.17182/hepdata.23382

Using the CUSB-II detector at the Cornell Electron Storage Ring, we have measured Bμμ, the branching fraction into muons, of the Υ’’ meson. We find Bμμ(Υ’’)=(1.53±0.33±0.21)%, from which the Υ’’ total decay width is 25.5±5.0 keV. From this result we obtain αs=0.170−0.012+0.015, ΛMS¯=148−39+56 MeV. (MS¯ denotes the modified minimal-subtraction scheme).

1 data table

No description provided.


An Improved measurement of alpha-s (M (Z0)) using energy correlations with the OPAL detector at LEP

The OPAL collaboration Acton, P.D. ; Alexander, G. ; Allison, J. ; et al.
Phys.Lett.B 276 (1992) 547-564, 1992.
Inspire Record 321657 DOI 10.17182/hepdata.29245

We report on an improved measurement of the value of the strong coupling constant σ s at the Z 0 peak, using the asymmetry of the energy-energy correlation function. The analysis, based on second-order perturbation theory and a data sample of about 145000 multihadronic Z 0 decays, yields α s ( M z 0 = 0.118±0.001(stat.)±0.003(exp.syst.) −0.004 +0.0009 (theor. syst.), where the theoretical systematic error accounts for uncertainties due to hadronization, the choice of the renormalization scale and unknown higher-order terms. We adjust the parameters of a second-order matrix element Monte Carlo followed by string hadronization to best describe the energy correlation and other hadronic Z 0 decay data. The α s result obtained from this second-order Monte Carlo is found to be unreliable if values of the renormalization scale smaller than about 0.15 E cm are used in the generator.

2 data tables

Value of LAMBDA(MSBAR) and ALPHA_S.. The first systematic error is experimental, the second is from theory.

The EEC and its asymmetry at the hadron level, unfolded for initial-state radiation and for detector acceptance and resolution. Errors include full statistical and systematic uncertainties.