Showing 3 of 3 results
The distributions of event-by-event harmonic flow coefficients v_n for n=2-4 are measured in sqrt(s_NN)=2.76 TeV Pb+Pb collisions using the ATLAS detector at the LHC. The measurements are performed using charged particles with transverse momentum pT> 0.5 GeV and in the pseudorapidity range |eta|<2.5 in a dataset of approximately 7 ub^-1 recorded in 2010. The shapes of the v_n distributions are described by a two-dimensional Gaussian function for the underlying flow vector in central collisions for v_2 and over most of the measured centrality range for v_3 and v_4. Significant deviations from this function are observed for v_2 in mid-central and peripheral collisions, and a small deviation is observed for v_3 in mid-central collisions. It is shown that the commonly used multi-particle cumulants are insensitive to the deviations for v_2. The v_n distributions are also measured independently for charged particles with 0.5<pT<1 GeV and pT>1 GeV. When these distributions are rescaled to the same mean values, the adjusted shapes are found to be nearly the same for these two pT ranges. The v_n distributions are compared with the eccentricity distributions from two models for the initial collision geometry: a Glauber model and a model that includes corrections to the initial geometry due to gluon saturation effects. Both models fail to describe the experimental data consistently over most of the measured centrality range.
The relationship between centrality intervals and MEAN(Npart) estimated from the Glauber model.
The MEAN(Npart) dependence of MEAN(V2) for three pT ranges together with the total systematic uncertainties.
The MEAN(Npart) dependence of SIGMA(V2) for three pT ranges together with the total systematic uncertainties.
The MEAN(Npart) dependence of SIGMA(V2)/MEAN(V2) for three pT ranges together with the total systematic uncertainties.
The MEAN(Npart) dependence of MEAN(V3) for three pT ranges together with the total systematic uncertainties.
The MEAN(Npart) dependence of SIGMA(V3) for three pT ranges together with the total systematic uncertainties.
The MEAN(Npart) dependence of SIGMA(V3)/MEAN(V3) for three pT ranges together with the total systematic uncertainties.
The MEAN(Npart) dependence of MEAN(V4) for three pT ranges together with the total systematic uncertainties.
The MEAN(Npart) dependence of SIGMA(V4) for three pT ranges together with the total systematic uncertainties.
The MEAN(Npart) dependence of SIGMA(V4)/MEAN(V4) for three pT ranges together with the total systematic uncertainties.
Eccentricity curves for EPSILON2 in Figure 12.
Eccentricity curves for EPSILON3 in Figure 12.
Eccentricity curves for EPSILON4 in Figure 12.
Comparison of MEAN(V2) and SQRT(MEAN(V2**2)), derived from the EbyE V2 distributions, with the V2(EP), for charged particles in the pT > 0.5 GeV range.
The ratios of SQRT(MEAN(V2**2)) and V2(EP) to MEAN(V2), for charged particles in the pT > 0.5 GeV range.
Comparison of MEAN(V3) and SQRT(MEAN(V3**2)), derived from the EbyE V3 distributions, with the V3(EP), for charged particles in the pT > 0.5 GeV range.
The ratios of SQRT(MEAN(V3**2)) and V3(EP) to MEAN(V3), for charged particles in the pT > 0.5 GeV range.
Comparison of MEAN(V4) and SQRT(MEAN(V4**2)), derived from the EbyE V4 distributions, with the V4(EP), for charged particles in the pT > 0.5 GeV range.
The ratios of SQRT(MEAN(V4**2)) and V4(EP) to MEAN(V4), for charged particles in the pT > 0.5 GeV range.
Comparison of MEAN(V2) and SQRT(MEAN(V2**2)), derived from the EbyE V2 distributions, with the V2(EP), for charged particles in the 0.5 < pT < 1 GeV range.
The ratios of SQRT(MEAN(V2**2)) and V2(EP) to MEAN(V2), for charged particles in the 0.5 < pT < 1 GeV range.
Comparison of MEAN(V3) and SQRT(MEAN(V3**2)), derived from the EbyE V3 distributions, with the V3(EP), for charged particles in the 0.5 < pT < 1 GeV range.
The ratios of SQRT(MEAN(V3**2)) and V3(EP) to MEAN(V3), for charged particles in the 0.5 < pT < 1 GeV range.
Comparison of MEAN(V4) and SQRT(MEAN(V4**2)), derived from the EbyE V4 distributions, with the V4(EP), for charged particles in the 0.5 < pT < 1 GeV range.
The ratios of SQRT(MEAN(V4**2)) and V4(EP) to MEAN(V4), for charged particles in the 0.5 < pT < 1 GeV range.
Comparison of MEAN(V2) and SQRT(MEAN(V2**2)), derived from the EbyE V2 distributions, with the V2(EP), for charged particles in the pT > 1 GeV range.
The ratios of SQRT(MEAN(V2**2)) and V2(EP) to MEAN(V2), for charged particles in the pT > 1 GeV range.
Comparison of MEAN(V3) and SQRT(MEAN(V3**2)), derived from the EbyE V3 distributions, with the V3(EP), for charged particles in the pT > 1 GeV range.
The ratios of SQRT(MEAN(V3**2)) and V3(EP) to MEAN(V3), for charged particles in the pT > 1 GeV range.
Comparison of MEAN(V4) and SQRT(MEAN(V4**2)), derived from the EbyE V4 distributions, with the V4(EP), for charged particles in the pT > 1 GeV range.
The ratios of SQRT(MEAN(V4**2)) and V4(EP) to MEAN(V4), for charged particles in the pT > 1 GeV range.
Bessel-Gaussian fit parameters from Eq. (1.4) and total errors.
The dependence of MEAN(V2) and V2(RP) on MEAN(Npart).
The dependence of SIGMA(V2) and DELTA(V2) on MEAN(Npart).
The dependence of SIGMA(V2) / MEAN(V2) and DELTA(V2) / V2(RP) on MEAN(Npart).
Comparison of the V2(RP) obtained from the Bessel-Gaussian fit of the V2 distributions with the values for two-particle (V2(calc){2}), four-particle (V2(calc){4}), six-particle (V2(calc){6}) and eight-particle (V2(calc){8}) cumulants calculated directly from the unfolded V2 distributions.
The ratios of the four-particle (V2(calc){4}), six-particle (V2(calc){6}) and eight-particle (V2(calc){8}) cumulants to the fit results (V2(RP)), with the total uncertainties.
The ratios of the six-particle (V2(calc){6}) and eight-particle (V2(calc){8}) cumulants to the four-particle (V2(calc){4}) cumulants, with the total uncertainties.
Comparison of the V3(RP) obtained from the Bessel-Gaussian fit of the V3 distributions with the values for two-particle (V3(calc){2}), four-particle (V3(calc){4}), six-particle (V3(calc){6}) and eight-particle (V3(calc){8}) cumulants calculated directly from the unfolded V3 distributions.
The ratios of the four-particle (V3(calc){4}), six-particle (V3(calc){6}) and eight-particle (V3(calc){8}) cumulants to the fit results (V3(RP)), with the total uncertainties.
The ratios of the six-particle (V3(calc){6}) and eight-particle (V3(calc){8}) cumulants to the four-particle (V3(calc){4}) cumulants, with the total uncertainties.
The standard deviation (SIGMA(V2)), the width obtained from Bessel-Gaussian function (DELTA(V2)), the width F1 = SQRT( ( V2(calc){2}**2 - V2(calc){4}**2 ) / 2 ) estimated from the two-particle cumulant (V2(calc){2}) and four-particle cumulant (V2(calc){4}), where these cumulants are calculated analytically via Eq. (5.3) from the V2 distribution.
Various estimates of the relative fluctuations given as SIGMA(V2) / MEAN(V2), DELTA(V2) / V2(RP), F2 = SQRT( ( V2(calc){2}**2 - V2(calc){4}**2) / ( 2*V2(calc){4}**2 ) ) and F3 = SQRT( ( V2(calc){2}**2 - V2(calc){4}**2) / ( V2(calc){2}**2 + V2(calc){4}**2 ) ).
Comparison in 0.5 < pT < 1 GeV of the V2(RP) obtained from the Bessel-Gaussian fit of the V2 distributions with the values for two-particle (V2(calc){2}), four-particle (V2(calc){4}), six-particle (V2(calc){6}) and eight-particle (V2(calc){8}) cumulants calculated directly from the unfolded V2 distributions.
The ratios for 0.5 < pT < 1 GeV of the four-particle (V2(calc){4}), six-particle (V2(calc){6}) and eight-particle (V2(calc){8}) cumulants to the fit results (V2(RP)), with the total uncertainties.
The ratios for 0.5 < pT < 1 GeV of the six-particle (V2(calc){6}) and eight-particle (V2(calc){8}) cumulants to the four-particle (V2(calc){4}) cumulants, with the total uncertainties.
Comparison in pT > 1 GeV of the V2(RP) obtained from the Bessel-Gaussian fit of the V2 distributions with the values for two-particle (V2(calc){2}), four-particle (V2(calc){4}), six-particle (V2(calc){6}) and eight-particle (V2(calc){8}) cumulants calculated directly from the unfolded V2 distributions.
The ratios for pT > 1 GeV of the four-particle (V2(calc){4}), six-particle (V2(calc){6}) and eight-particle (V2(calc){8}) cumulants to the fit results (V2(RP)), with the total uncertainties.
The ratios for pT > 1 GeV of the six-particle (V2(calc){6}) and eight-particle (V2(calc){8}) cumulants to the four-particle (V2(calc){4}) cumulants, with the total uncertainties.
The values of V2(RP) and V2(RP,obs) obtained from the Bessel-Gaussian fits to the V2 and V2(obs) distributions, with the statistical uncertainties.
The values of DELTA(V2) and DELTA(V2,obs) obtained from the Bessel-Gaussian fits to the V2 and V2(obs) distributions, with the statistical uncertainties.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
The integrated elliptic flow of charged particles produced in Pb+Pb collisions at sqrt(s_NN)=2.76 TeV has been measured with the ATLAS detector using data collected at the Large Hadron Collider. The anisotropy parameter, v_2, was measured in the pseudorapidity range |eta| <= 2.5 with the event-plane method. In order to include tracks with very low transverse momentum pT, thus reducing the uncertainty in v_2 integrated over pT, a 1 mu b-1 data sample without a magnetic field in the tracking detectors is used. The centrality dependence of the integrated v_2 is compared to other measurements obtained with higher pT thresholds. A weak pseudorapidity dependence of the integrated elliptic flow is observed for central collisions, and a small decrease when moving away from mid-rapidity is observed only in peripheral collisions. The integrated v2 transformed to the rest frame of one of the colliding nuclei is compared to the lower-energy RHIC data.
Monte Carlo evaluation of the tracklet reconstruction efficiency as a function of pseudorapidity for the 0-10% centraliry interval.
Monte Carlo evaluation of the tracklet reconstruction efficiency as a function of pseudorapidity for the 40-50% centraliry interval.
Monte Carlo evaluation of the tracklet reconstruction efficiency as a function of pseudorapidity for the 70-80% centraliry interval.
The transverse momentum, $p_{T}$, dependence of the pixel track (PXT) reconstruction efficiency for three pseudorapidity ranges in 0-10% centrality interval.
The transverse momentum, $p_{T}$, dependence of the pixel track (PXT) reconstruction efficiency for three pseudorapidity ranges in 40-50% centrality interval.
The transverse momentum, $p_{T}$, dependence of the pixel track (PXT) reconstruction efficiency for three pseudorapidity ranges in 70-80% centrality interval.
The transverse momentum, $p_{T}$, dependence of the pixel track (PXT) reconstruction fake rate for three pseudorapidity ranges in 0-10% centrality interval.
The transverse momentum, $p_{T}$, dependence of the pixel track (PXT) reconstruction fake rate for three pseudorapidity ranges in 40-50% centrality interval.
The transverse momentum, $p_{T}$, dependence of the pixel track (PXT) reconstruction fake rate for three pseudorapidity ranges in 70-80% centrality interval.
The transverse momentum, $p_{T}$, dependence of the inner detector track (IDT) reconstruction efficiency for three pseudorapidity ranges in 0-10% centrality interval.
The transverse momentum, $p_{T}$, dependence of the inner detector track (IDT) reconstruction efficiency for three pseudorapidity ranges in 40-50% centrality interval.
The transverse momentum, $p_{T}$, dependence of the inner detector track (IDT) reconstruction efficiency for three pseudorapidity ranges in 70-80% centrality interval.
The transverse momentum, $p_{T}$, dependence of the inner detector track (IDT) reconstruction fake rate for three pseudorapidity ranges in 0-10% centrality interval.
The transverse momentum, $p_{T}$, dependence of the inner detector track (IDT) reconstruction fake rate for three pseudorapidity ranges in 40-50% centrality interval.
The transverse momentum, $p_{T}$, dependence of the inner detector track (IDT) reconstruction fake rate for three pseudorapidity ranges in 70-80% centrality interval.
Elliptic flow $v_{2}$ integrated over transverse momentum $p_{T}>p_{T,0}$ as a function of $p_{T,0}$ for 0-10% centrality interval, obtained with different charged-particle reconstruction methods: the tracklet (TKT) method with $p_{T,0}=0.07$ GeV, the pixel track (PXT) method with $p_{T,0} \geq 0.1$ GeV and the ID track (IDT) method with $p_{T,0}=0.5$ GeV. Error bars indicate statistical and systematic uncertainties added in quadrature.
Elliptic flow $v_{2}$ integrated over transverse momentum $p_{T}>p_{T,0}$ as a function of $p_{T,0}$ for 10-20% centrality interval, obtained with different charged-particle reconstruction methods: the tracklet (TKT) method with $p_{T,0}=0.07$ GeV, the pixel track (PXT) method with $p_{T,0} \geq 0.1$ GeV and the ID track (IDT) method with $p_{T,0}=0.5$ GeV. Error bars indicate statistical and systematic uncertainties added in quadrature.
Elliptic flow $v_{2}$ integrated over transverse momentum $p_{T}>p_{T,0}$ as a function of $p_{T,0}$ for 20-30% centrality interval, obtained with different charged-particle reconstruction methods: the tracklet (TKT) method with $p_{T,0}=0.07$ GeV, the pixel track (PXT) method with $p_{T,0} \geq 0.1$ GeV and the ID track (IDT) method with $p_{T,0}=0.5$ GeV. Error bars indicate statistical and systematic uncertainties added in quadrature.
Elliptic flow $v_{2}$ integrated over transverse momentum $p_{T}>p_{T,0}$ as a function of $p_{T,0}$ for 30-40% centrality interval, obtained with different charged-particle reconstruction methods: the tracklet (TKT) method with $p_{T,0}=0.07$ GeV, the pixel track (PXT) method with $p_{T,0} \geq 0.1$ GeV and the ID track (IDT) method with $p_{T,0}=0.5$ GeV. Error bars indicate statistical and systematic uncertainties added in quadrature.
Elliptic flow $v_{2}$ integrated over transverse momentum $p_{T}>p_{T,0}$ as a function of $p_{T,0}$ for 40-50% centrality interval, obtained with different charged-particle reconstruction methods: the tracklet (TKT) method with $p_{T,0}=0.07$ GeV, the pixel track (PXT) method with $p_{T,0} \geq 0.1$ GeV and the ID track (IDT) method with $p_{T,0}=0.5$ GeV. Error bars indicate statistical and systematic uncertainties added in quadrature.
Elliptic flow $v_{2}$ integrated over transverse momentum $p_{T}>p_{T,0}$ as a function of $p_{T,0}$ for 50-60% centrality interval, obtained with different charged-particle reconstruction methods: the tracklet (TKT) method with $p_{T,0}=0.07$ GeV, the pixel track (PXT) method with $p_{T,0} \geq 0.1$ GeV and the ID track (IDT) method with $p_{T,0}=0.5$ GeV. Error bars indicate statistical and systematic uncertainties added in quadrature.
Elliptic flow $v_{2}$ integrated over transverse momentum $p_{T}>p_{T,0}$ as a function of $p_{T,0}$ for 60-70% centrality interval, obtained with different charged-particle reconstruction methods: the tracklet (TKT) method with $p_{T,0}=0.07$ GeV, the pixel track (PXT) method with $p_{T,0} \geq 0.1$ GeV and the ID track (IDT) method with $p_{T,0}=0.5$ GeV. Error bars indicate statistical and systematic uncertainties added in quadrature.
Elliptic flow $v_{2}$ integrated over transverse momentum $p_{T}>p_{T,0}$ as a function of $p_{T,0}$ for 70-80% centrality interval, obtained with different charged-particle reconstruction methods: the tracklet (TKT) method with $p_{T,0}=0.07$ GeV, the pixel track (PXT) method with $p_{T,0} \geq 0.1$ GeV and the ID track (IDT) method with $p_{T,0}=0.5$ GeV. Error bars indicate statistical and systematic uncertainties added in quadrature.
Pseudorapidity dependence of elliptic flow, $v_{2}$, integrated over transverse momentum, $p_{T}$, for different charged particle reconstruction methods and different low-$p_{T}$ thresholds for the 0-10% centrality interval. Error bars indicate statistical and systematic uncertainties added in quadrature.
Pseudorapidity dependence of elliptic flow, $v_{2}$, integrated over transverse momentum, $p_{T}$, for different charged particle reconstruction methods and different low-$p_{T}$ thresholds for the 10-20% centrality interval. Error bars indicate statistical and systematic uncertainties added in quadrature.
Pseudorapidity dependence of elliptic flow, $v_{2}$, integrated over transverse momentum, $p_{T}$, for different charged particle reconstruction methods and different low-$p_{T}$ thresholds for the 20-30% centrality interval. Error bars indicate statistical and systematic uncertainties added in quadrature.
Pseudorapidity dependence of elliptic flow, $v_{2}$, integrated over transverse momentum, $p_{T}$, for different charged particle reconstruction methods and different low-$p_{T}$ thresholds for the 30-40% centrality interval. Error bars indicate statistical and systematic uncertainties added in quadrature.
Pseudorapidity dependence of elliptic flow, $v_{2}$, integrated over transverse momentum, $p_{T}$, for different charged particle reconstruction methods and different low-$p_{T}$ thresholds for the 40-50% centrality interval. Error bars indicate statistical and systematic uncertainties added in quadrature.
Pseudorapidity dependence of elliptic flow, $v_{2}$, integrated over transverse momentum, $p_{T}$, for different charged particle reconstruction methods and different low-$p_{T}$ thresholds for the 50-60% centrality interval. Error bars indicate statistical and systematic uncertainties added in quadrature.
Pseudorapidity dependence of elliptic flow, $v_{2}$, integrated over transverse momentum, $p_{T}$, for different charged particle reconstruction methods and different low-$p_{T}$ thresholds for the 60-70% centrality interval. Error bars indicate statistical and systematic uncertainties added in quadrature.
Pseudorapidity dependence of elliptic flow, $v_{2}$, integrated over transverse momentum, $p_{T}$, for different charged particle reconstruction methods and different low-$p_{T}$ thresholds for the 70-80% centrality interval. Error bars indicate statistical and systematic uncertainties added in quadrature.
Integrated elliptic flow, $v_{2}$, as a function of $|\eta| - y_{beam}$ for three centrality intervals Error bars indicate statistical and systematic uncertainties added in quadrature.
The transverse momentum, $p_{T}$, dependence of the TKT track reconstruction efficiency for $\pi^{\pm}$, $K^{\pm}$ and $p^{\pm}$ in the pseudorapidity range $|\eta| < 1$ for 0-10% centrality interval.
The transverse momentum, $p_{T}$, dependence of the TKT track reconstruction efficiency for $\pi^{\pm}$, $K^{\pm}$ and $p^{\pm}$ in the pseudorapidity range $|\eta| < 1$ for 40-50% centrality interval.
The transverse momentum, $p_{T}$, dependence of the TKT track reconstruction efficiency for $\pi^{\pm}$, $K^{\pm}$ and $p^{\pm}$ in the pseudorapidity range $|\eta| < 1$ for 70-80% centrality interval.
The transverse momentum, $p_{T}$, dependence of the PXT track reconstruction efficiency for $\pi^{\pm}$, $K^{\pm}$ and $p^{\pm}$ in the pseudorapidity range $|\eta| < 1$ for 0-10% centrality interval.
The transverse momentum, $p_{T}$, dependence of the PXT track reconstruction efficiency for $\pi^{\pm}$, $K^{\pm}$ and $p^{\pm}$ in the pseudorapidity range $|\eta| < 1$ for 40-50% centrality interval.
The transverse momentum, $p_{T}$, dependence of the PXT track reconstruction efficiency for $\pi^{\pm}$, $K^{\pm}$ and $p^{\pm}$ in the pseudorapidity range $|\eta| < 1$ for 70-80% centrality interval.
ATLAS measurements of the azimuthal anisotropy in lead-lead collisions at $\sqrt{s_{NN}}=2.76$ TeV are shown using a dataset of approximately 7 $\mu$b$^{-1}$ collected at the LHC in 2010. The measurements are performed for charged particles with transverse momenta $0.5<p_T<20$ GeV and in the pseudorapidity range $|\eta|<2.5$. The anisotropy is characterized by the Fourier coefficients, $v_n$, of the charged-particle azimuthal angle distribution for n = 2-4. The Fourier coefficients are evaluated using multi-particle cumulants calculated with the generating function method. Results on the transverse momentum, pseudorapidity and centrality dependence of the $v_n$ coefficients are presented. The elliptic flow, $v_2$, is obtained from the two-, four-, six- and eight-particle cumulants while higher-order coefficients, $v_3$ and $v_4$, are determined with two- and four-particle cumulants. Flow harmonics $v_n$ measured with four-particle cumulants are significantly reduced compared to the measurement involving two-particle cumulants. A comparison to $v_n$ measurements obtained using different analysis methods and previously reported by the LHC experiments is also shown. Results of measurements of flow fluctuations evaluated with multi-particle cumulants are shown as a function of transverse momentum and the collision centrality. Models of the initial spatial geometry and its fluctuations fail to describe the flow fluctuations measurements.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 0-2%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 2-5%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 5-10%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 10-15%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 15-20%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 20-25%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 25-30%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 30-35%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 35-40%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 40-45%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 45-50%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 50-55%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 55-60%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 60-80%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 0-2%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 2-5%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 5-10%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 10-15%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 15-20%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 20-25%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 25-30%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 30-35%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 35-40%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 40-45%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 45-50%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 50-55%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 55-60%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 60-80%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 2-5%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 5-10%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 10-15%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 15-20%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 20-25%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 25-30%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 30-35%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 35-40%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 40-45%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 45-50%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 50-55%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 55-60%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 60-80%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 2-5%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 5-10%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 10-15%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 15-20%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 20-25%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 25-30%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 30-35%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 35-40%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 40-45%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 45-50%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 50-55%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 55-60%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 60-80%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 2-5%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 5-10%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 10-15%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 15-20%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 20-25%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 25-30%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 30-35%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 35-40%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 40-45%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 45-50%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 50-55%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 55-60%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 60-80%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 5-10%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 15-20%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 25-30%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 35-40%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 40-50%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 10-20%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 20-30%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 30-40%.
The triangular flow harmonic measured with the two-particle cumulats as a function of transverse momentum in centrality bin 0-25%.
The triangular flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 0-25%.
The triangular flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 0-25%.
The triangular flow harmonic measured with the two-particle cumulats as a function of transverse momentum in centrality bin 25-60%.
The triangular flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 25-60%.
The triangular flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 25-60%.
The quadrangular flow harmonic measured with the two-particle cumulats as a function of transverse momentum in centrality bin 0-25%.
The quadrangular flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 0-25%.
The quadrangular flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 0-25%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 0-2%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 2-5%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 5-10%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 10-15%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 15-20%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 20-25%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 25-30%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 30-35%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 35-40%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 40-45%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 45-50%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 50-55%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 55-60%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 60-80%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 0-2%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 2-5%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 5-10%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 10-15%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 15-20%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 20-25%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 25-30%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 30-35%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 35-40%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 40-45%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 45-50%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 50-55%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 55-60%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 60-80%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 2-5%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 5-10%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 10-15%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 15-20%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 20-25%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 25-30%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 30-35%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 35-40%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 40-45%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 45-50%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 50-55%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 55-60%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 60-80%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 2-5%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 5-10%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 10-15%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 15-20%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 20-25%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 25-30%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 30-35%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 35-40%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 40-45%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 45-50%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 50-55%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 55-60%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 60-80%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 2-5%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 5-10%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 10-15%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 15-20%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 20-25%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 25-30%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 30-35%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 35-40%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 40-45%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 45-50%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 50-55%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 55-60%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 60-80%.
The triangular flow harmonic measured with the two-particle cumulats as a function of pseudorapidity in centrality bin 0-60%.
The triangular flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 0-60%.
The triangular flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 0-60%.
The quadrangular flow harmonic measured with the two-particle cumulats as a function of pseudorapidity in centrality bin 0-25%.
The quadrangular flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 0-25%.
The quadrangular flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 0-25%.
The second flow harmonic measured with the two-particle cumulats as a function of <Npart>.
The second flow harmonic measured with the four-particle cumulats as a function of <Npart>.
The second flow harmonic measured with the six-particle cumulats as a function of <Npart>.
The second flow harmonic measured with the eight-particle cumulats as a function of <Npart>.
The ratio of second flow harmonics measured with the six- and four-particle cumulants as a function of <Npart>.
The ratio of second flow harmonics measured with the eight- and four-particle cumulants as a function of <Npart>.
The second flow harmonic measured with the Event Plane method as a function of <Npart>.
The triangular flow harmonic measured with the Event Plane method as a function of <Npart>.
The triangular flow harmonic measured with the two-particle cumulants as a function of <Npart>.
The triangular flow harmonic measured with the two-particle cumulants as a function of <Npart>.
The quadrangular flow harmonic measured with the Event Plane method as a function of <Npart>.
The quadrangular flow harmonic measured with the two-particle cumulants as a function of <Npart>.
The quadrangular flow harmonic measured with the two-particle cumulants as a function of <Npart>.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 2-5%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 5-10%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 10-15%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 15-20%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 20-25%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 25-30%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 30-35%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 35-40%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 40-45%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 45-50%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 50-55%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 55-60%.
The second flow harmonic fluctuations, F(v2), as a function of <Npart>.
The triangular flow harmonic fluctuations, F(v3), as a function of <Npart>.
The triangular flow harmonic fluctuations, F(v4), as a function of <Npart>.
The second flow harmonic measured with the two-particle cumulats as a function of <Npart>.
The second flow harmonic measured with the four-particle cumulats as a function of <Npart>.
The second flow harmonic measured with the six-particle cumulats as a function of <Npart>.
The second flow harmonic measured with the eight-particle cumulats as a function of <Npart>.
The ratio of second flow harmonics measured with the six- and four-particle cumulants as a function of <Npart>.
The ratio of second flow harmonics measured with the eight- and four-particle cumulants as a function of <Npart>.
The triangular flow harmonic measured with the two-particle cumulants as a function of <Npart>.
The quadrangular flow harmonic measured with the Event Plane method as a function of <Npart>.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 2-5%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 5-10%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 10-15%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 15-20%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 20-25%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 25-30%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 30-35%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 35-40%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 40-45%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 45-50%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 50-55%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 55-60%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 2-5%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 5-10%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 10-15%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 15-20%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 20-25%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 25-30%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 30-35%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 35-40%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 40-45%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 45-50%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 50-55%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 55-60%.
The second flow harmonic fluctuations, F(v2), as a function of <Npart>.
The triangular flow harmonic fluctuations, F(v3), as a function of <Npart>.
The triangular flow harmonic fluctuations, F(v4), as a function of <Npart>.
When you search on a word, e.g. 'collisions', we will automatically search across everything we store about a record. But sometimes you may wish to be more specific. Here we show you how.
Guidance on the query string syntax can also be found in the OpenSearch documentation.
About HEPData Submitting to HEPData HEPData File Formats HEPData Coordinators HEPData Terms of Use HEPData Cookie Policy
Status Email Forum Twitter GitHub
Copyright ~1975-Present, HEPData | Powered by Invenio, funded by STFC, hosted and originally developed at CERN, supported and further developed at IPPP Durham.