Showing 10 of 27 results
ATLAS measurements of the azimuthal anisotropy in lead-lead collisions at $\sqrt{s_{NN}}=2.76$ TeV are shown using a dataset of approximately 7 $\mu$b$^{-1}$ collected at the LHC in 2010. The measurements are performed for charged particles with transverse momenta $0.5<p_T<20$ GeV and in the pseudorapidity range $|\eta|<2.5$. The anisotropy is characterized by the Fourier coefficients, $v_n$, of the charged-particle azimuthal angle distribution for n = 2-4. The Fourier coefficients are evaluated using multi-particle cumulants calculated with the generating function method. Results on the transverse momentum, pseudorapidity and centrality dependence of the $v_n$ coefficients are presented. The elliptic flow, $v_2$, is obtained from the two-, four-, six- and eight-particle cumulants while higher-order coefficients, $v_3$ and $v_4$, are determined with two- and four-particle cumulants. Flow harmonics $v_n$ measured with four-particle cumulants are significantly reduced compared to the measurement involving two-particle cumulants. A comparison to $v_n$ measurements obtained using different analysis methods and previously reported by the LHC experiments is also shown. Results of measurements of flow fluctuations evaluated with multi-particle cumulants are shown as a function of transverse momentum and the collision centrality. Models of the initial spatial geometry and its fluctuations fail to describe the flow fluctuations measurements.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 0-2%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 2-5%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 5-10%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 10-15%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 15-20%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 20-25%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 25-30%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 30-35%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 35-40%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 40-45%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 45-50%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 50-55%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 55-60%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 60-80%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 0-2%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 2-5%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 5-10%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 10-15%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 15-20%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 20-25%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 25-30%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 30-35%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 35-40%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 40-45%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 45-50%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 50-55%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 55-60%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 60-80%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 2-5%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 5-10%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 10-15%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 15-20%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 20-25%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 0-2%.
The triangular flow harmonic measured with the two-particle cumulats as a function of pseudorapidity in centrality bin 0-60%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 2-5%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 5-10%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 10-15%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 15-20%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 20-25%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 25-30%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 30-35%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 35-40%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 40-45%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 45-50%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 50-55%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 55-60%.
The second flow harmonic fluctuations, F(v2), as a function of <Npart>.
The triangular flow harmonic fluctuations, F(v3), as a function of <Npart>.
The triangular flow harmonic fluctuations, F(v4), as a function of <Npart>.
The triangular flow harmonic measured with the two-particle cumulants as a function of <Npart>.
The quadrangular flow harmonic measured with the Event Plane method as a function of <Npart>.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 2-5%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 5-10%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 10-15%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 15-20%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 20-25%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 25-30%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 30-35%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 35-40%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 40-45%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 45-50%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 50-55%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 55-60%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 2-5%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 5-10%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 10-15%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 15-20%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 20-25%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 25-30%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 30-35%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 35-40%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 40-45%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 45-50%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 50-55%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 55-60%.
The second flow harmonic fluctuations, F(v2), as a function of <Npart>.
The triangular flow harmonic fluctuations, F(v3), as a function of <Npart>.
The triangular flow harmonic fluctuations, F(v4), as a function of <Npart>.
Correlations between the elliptic or triangular flow coefficients $v_m$ ($m$=2 or 3) and other flow harmonics $v_n$ ($n$=2 to 5) are measured using $\sqrt{s_{NN}}=2.76$ TeV Pb+Pb collision data collected in 2010 by the ATLAS experiment at the LHC, corresponding to an integrated lumonisity of 7 $\mu$b$^{-1}$. The $v_m$-$v_n$ correlations are measured in midrapidity as a function of centrality, and, for events within the same centrality interval, as a function of event ellipticity or triangularity defined in a forward rapidity region. For events within the same centrality interval, $v_3$ is found to be anticorrelated with $v_2$ and this anticorrelation is consistent with similar anticorrelations between the corresponding eccentricities $\epsilon_2$ and $\epsilon_3$. On the other hand, it is observed that $v_4$ increases strongly with $v_2$, and $v_5$ increases strongly with both $v_2$ and $v_3$. The trend and strength of the $v_m$-$v_n$ correlations for $n$=4 and 5 are found to disagree with $\epsilon_m$-$\epsilon_n$ correlations predicted by initial-geometry models. Instead, these correlations are found to be consistent with the combined effects of a linear contribution to $v_n$ and a nonlinear term that is a function of $v_2^2$ or of $v_2v_3$, as predicted by hydrodynamic models. A simple two-component fit is used to separate these two contributions. The extracted linear and nonlinear contributions to $v_4$ and $v_5$ are found to be consistent with previously measured event-plane correlations.
$v_{2}$ data for various $q_2$ bins, Centrality 0-5%.
$v_{3}$ data for various $q_2$ bins, Centrality 0-5%.
$v_{4}$ data for various $q_2$ bins, Centrality 0-5%.
$v_{5}$ data for various $q_2$ bins, Centrality 0-5%.
$v_{2}$ data for various $q_2$ bins, Centrality 5-10%.
$v_{3}$ data for various $q_2$ bins, Centrality 5-10%.
$v_{4}$ data for various $q_2$ bins, Centrality 5-10%.
$v_{5}$ data for various $q_2$ bins, Centrality 5-10%.
$v_{2}$ data for various $q_2$ bins, Centrality 10-15%.
$v_{3}$ data for various $q_2$ bins, Centrality 10-15%.
$v_{4}$ data for various $q_2$ bins, Centrality 10-15%.
$v_{5}$ data for various $q_2$ bins, Centrality 10-15%.
$v_{2}$ data for various $q_2$ bins, Centrality 15-20%.
$v_{3}$ data for various $q_2$ bins, Centrality 15-20%.
$v_{4}$ data for various $q_2$ bins, Centrality 15-20%.
$v_{5}$ data for various $q_2$ bins, Centrality 15-20%.
$v_{2}$ data for various $q_2$ bins, Centrality 20-25%.
$v_{3}$ data for various $q_2$ bins, Centrality 20-25%.
$v_{4}$ data for various $q_2$ bins, Centrality 20-25%.
$v_{5}$ data for various $q_2$ bins, Centrality 20-25%.
$v_{2}$ data for various $q_2$ bins, Centrality 25-30%.
$v_{3}$ data for various $q_2$ bins, Centrality 25-30%.
$v_{4}$ data for various $q_2$ bins, Centrality 25-30%.
$v_{5}$ data for various $q_2$ bins, Centrality 25-30%.
$v_{2}$ data for various $q_2$ bins, Centrality 30-35%.
$v_{3}$ data for various $q_2$ bins, Centrality 30-35%.
$v_{4}$ data for various $q_2$ bins, Centrality 30-35%.
$v_{5}$ data for various $q_2$ bins, Centrality 30-35%.
$v_{2}$ data for various $q_2$ bins, Centrality 35-40%.
$v_{3}$ data for various $q_2$ bins, Centrality 35-40%.
$v_{4}$ data for various $q_2$ bins, Centrality 35-40%.
$v_{5}$ data for various $q_2$ bins, Centrality 35-40%.
$v_{2}$ data for various $q_2$ bins, Centrality 40-45%.
$v_{3}$ data for various $q_2$ bins, Centrality 40-45%.
$v_{4}$ data for various $q_2$ bins, Centrality 40-45%.
$v_{5}$ data for various $q_2$ bins, Centrality 40-45%.
$v_{2}$ data for various $q_2$ bins, Centrality 45-50%.
$v_{3}$ data for various $q_2$ bins, Centrality 45-50%.
$v_{4}$ data for various $q_2$ bins, Centrality 45-50%.
$v_{5}$ data for various $q_2$ bins, Centrality 45-50%.
$v_{2}$ data for various $q_2$ bins, Centrality 50-55%.
$v_{3}$ data for various $q_2$ bins, Centrality 50-55%.
$v_{4}$ data for various $q_2$ bins, Centrality 50-55%.
$v_{5}$ data for various $q_2$ bins, Centrality 50-55%.
$v_{2}$ data for various $q_2$ bins, Centrality 55-60%.
$v_{3}$ data for various $q_2$ bins, Centrality 55-60%.
$v_{4}$ data for various $q_2$ bins, Centrality 55-60%.
$v_{5}$ data for various $q_2$ bins, Centrality 55-60%.
$v_{2}$ data for various $q_2$ bins, Centrality 60-65%.
$v_{3}$ data for various $q_2$ bins, Centrality 60-65%.
$v_{4}$ data for various $q_2$ bins, Centrality 60-65%.
$v_{5}$ data for various $q_2$ bins, Centrality 60-65%.
$v_{2}$ data for various $q_2$ bins, Centrality 65-70%.
$v_{3}$ data for various $q_2$ bins, Centrality 65-70%.
$v_{4}$ data for various $q_2$ bins, Centrality 65-70%.
$v_{5}$ data for various $q_2$ bins, Centrality 65-70%.
$v_{2}$ data for various $q_2$ bins, Centrality 0-10%.
$v_{3}$ data for various $q_2$ bins, Centrality 0-10%.
$v_{4}$ data for various $q_2$ bins, Centrality 0-10%.
$v_{5}$ data for various $q_2$ bins, Centrality 0-10%.
$v_{2}$ data for various $q_2$ bins, Centrality 10-20%.
$v_{3}$ data for various $q_2$ bins, Centrality 10-20%.
$v_{4}$ data for various $q_2$ bins, Centrality 10-20%.
$v_{5}$ data for various $q_2$ bins, Centrality 10-20%.
$v_{2}$ data for various $q_2$ bins, Centrality 20-30%.
$v_{3}$ data for various $q_2$ bins, Centrality 20-30%.
$v_{4}$ data for various $q_2$ bins, Centrality 20-30%.
$v_{5}$ data for various $q_2$ bins, Centrality 20-30%.
$v_{2}$ data for various $q_2$ bins, Centrality 30-40%.
$v_{3}$ data for various $q_2$ bins, Centrality 30-40%.
$v_{4}$ data for various $q_2$ bins, Centrality 30-40%.
$v_{5}$ data for various $q_2$ bins, Centrality 30-40%.
$v_{2}$ data for various $q_2$ bins, Centrality 40-50%.
$v_{3}$ data for various $q_2$ bins, Centrality 40-50%.
$v_{4}$ data for various $q_2$ bins, Centrality 40-50%.
$v_{5}$ data for various $q_2$ bins, Centrality 40-50%.
$v_{2}$ data for various $q_3$ bins, Centrality 0-5%.
$v_{3}$ data for various $q_3$ bins, Centrality 0-5%.
$v_{4}$ data for various $q_3$ bins, Centrality 0-5%.
$v_{5}$ data for various $q_3$ bins, Centrality 0-5%.
$v_{2}$ data for various $q_3$ bins, Centrality 5-10%.
$v_{3}$ data for various $q_3$ bins, Centrality 5-10%.
$v_{4}$ data for various $q_3$ bins, Centrality 5-10%.
$v_{5}$ data for various $q_3$ bins, Centrality 5-10%.
$v_{2}$ data for various $q_3$ bins, Centrality 10-15%.
$v_{3}$ data for various $q_3$ bins, Centrality 10-15%.
$v_{4}$ data for various $q_3$ bins, Centrality 10-15%.
$v_{5}$ data for various $q_3$ bins, Centrality 10-15%.
$v_{2}$ data for various $q_3$ bins, Centrality 15-20%.
$v_{3}$ data for various $q_3$ bins, Centrality 15-20%.
$v_{4}$ data for various $q_3$ bins, Centrality 15-20%.
$v_{5}$ data for various $q_3$ bins, Centrality 15-20%.
$v_{2}$ data for various $q_3$ bins, Centrality 20-25%.
$v_{3}$ data for various $q_3$ bins, Centrality 20-25%.
$v_{4}$ data for various $q_3$ bins, Centrality 20-25%.
$v_{5}$ data for various $q_3$ bins, Centrality 20-25%.
$v_{2}$ data for various $q_3$ bins, Centrality 25-30%.
$v_{3}$ data for various $q_3$ bins, Centrality 25-30%.
$v_{4}$ data for various $q_3$ bins, Centrality 25-30%.
$v_{5}$ data for various $q_3$ bins, Centrality 25-30%.
$v_{2}$ data for various $q_3$ bins, Centrality 30-35%.
$v_{3}$ data for various $q_3$ bins, Centrality 30-35%.
$v_{4}$ data for various $q_3$ bins, Centrality 30-35%.
$v_{5}$ data for various $q_3$ bins, Centrality 30-35%.
$v_{2}$ data for various $q_3$ bins, Centrality 35-40%.
$v_{3}$ data for various $q_3$ bins, Centrality 35-40%.
$v_{4}$ data for various $q_3$ bins, Centrality 35-40%.
$v_{5}$ data for various $q_3$ bins, Centrality 35-40%.
$v_{2}$ data for various $q_3$ bins, Centrality 40-45%.
$v_{3}$ data for various $q_3$ bins, Centrality 40-45%.
$v_{4}$ data for various $q_3$ bins, Centrality 40-45%.
$v_{5}$ data for various $q_3$ bins, Centrality 40-45%.
$v_{2}$ data for various $q_3$ bins, Centrality 45-50%.
$v_{3}$ data for various $q_3$ bins, Centrality 45-50%.
$v_{4}$ data for various $q_3$ bins, Centrality 45-50%.
$v_{5}$ data for various $q_3$ bins, Centrality 45-50%.
$v_{2}$ data for various $q_3$ bins, Centrality 50-55%.
$v_{3}$ data for various $q_3$ bins, Centrality 50-55%.
$v_{4}$ data for various $q_3$ bins, Centrality 50-55%.
$v_{5}$ data for various $q_3$ bins, Centrality 50-55%.
$v_{2}$ data for various $q_3$ bins, Centrality 55-60%.
$v_{3}$ data for various $q_3$ bins, Centrality 55-60%.
$v_{4}$ data for various $q_3$ bins, Centrality 55-60%.
$v_{5}$ data for various $q_3$ bins, Centrality 55-60%.
$v_{2}$ data for various $q_3$ bins, Centrality 60-65%.
$v_{3}$ data for various $q_3$ bins, Centrality 60-65%.
$v_{4}$ data for various $q_3$ bins, Centrality 60-65%.
$v_{5}$ data for various $q_3$ bins, Centrality 60-65%.
$v_{2}$ data for various $q_3$ bins, Centrality 65-70%.
$v_{3}$ data for various $q_3$ bins, Centrality 65-70%.
$v_{4}$ data for various $q_3$ bins, Centrality 65-70%.
$v_{5}$ data for various $q_3$ bins, Centrality 65-70%.
$v_{2}$ data for various $q_3$ bins, Centrality 0-10%.
$v_{3}$ data for various $q_3$ bins, Centrality 0-10%.
$v_{4}$ data for various $q_3$ bins, Centrality 0-10%.
$v_{5}$ data for various $q_3$ bins, Centrality 0-10%.
$v_{2}$ data for various $q_3$ bins, Centrality 10-20%.
$v_{3}$ data for various $q_3$ bins, Centrality 10-20%.
$v_{4}$ data for various $q_3$ bins, Centrality 10-20%.
$v_{5}$ data for various $q_3$ bins, Centrality 10-20%.
$v_{2}$ data for various $q_3$ bins, Centrality 20-30%.
$v_{3}$ data for various $q_3$ bins, Centrality 20-30%.
$v_{4}$ data for various $q_3$ bins, Centrality 20-30%.
$v_{5}$ data for various $q_3$ bins, Centrality 20-30%.
$v_{2}$ data for various $q_3$ bins, Centrality 30-40%.
$v_{3}$ data for various $q_3$ bins, Centrality 30-40%.
$v_{4}$ data for various $q_3$ bins, Centrality 30-40%.
$v_{5}$ data for various $q_3$ bins, Centrality 30-40%.
$v_{2}$ data for various $q_3$ bins, Centrality 40-50%.
$v_{3}$ data for various $q_3$ bins, Centrality 40-50%.
$v_{4}$ data for various $q_3$ bins, Centrality 40-50%.
$v_{5}$ data for various $q_3$ bins, Centrality 40-50%.
$v_{2}$ - $v_{2}$ inclusive correlation in 5% centrality intervals.
$v_{2}$ - $v_{2}$ correlation within each centrality.
$v_{2}$ - $v_{2}$ inclusive correlation in 5% centrality intervals.
$v_{2}$ - $v_{2}$ correlation within each centrality.
$v_{2}$ - $v_{2}$ inclusive correlation in 5% centrality intervals.
$v_{2}$ - $v_{2}$ correlation within each centrality.
$v_{2}$ - $v_{2}$ inclusive correlation in 5% centrality intervals.
$v_{2}$ - $v_{2}$ correlation within each centrality.
$v_{2}$ - $v_{2}$ inclusive correlation in 5% centrality intervals.
$v_{2}$ - $v_{2}$ correlation within each centrality.
$v_{3}$ - $v_{3}$ inclusive correlation in 5% centrality intervals.
$v_{3}$ - $v_{3}$ correlation within each centrality.
$v_{3}$ - $v_{3}$ inclusive correlation in 5% centrality intervals.
$v_{3}$ - $v_{3}$ correlation within each centrality.
$v_{3}$ - $v_{3}$ inclusive correlation in 5% centrality intervals.
$v_{3}$ - $v_{3}$ correlation within each centrality.
$v_{3}$ - $v_{3}$ inclusive correlation in 5% centrality intervals.
$v_{3}$ - $v_{3}$ correlation within each centrality.
$v_{2}$ - $v_{3}$ inclusive correlation in 5% centrality intervals.
$v_{2}$ - $v_{3}$ correlation for various q2 bins within each centrality.
$v_{2}$ - $v_{3}$ inclusive correlation in 5% centrality intervals.
$v_{2}$ - $v_{3}$ correlation for various q2 bins within each centrality.
$v_{2}$ - $v_{3}$ inclusive correlation in 5% centrality intervals.
$v_{2}$ - $v_{3}$ correlation for various q2 bins within each centrality.
$v_{2}$ - $v_{3}$ inclusive correlation in 5% centrality intervals.
$v_{2}$ - $v_{3}$ correlation for various q2 bins within each centrality.
linear fit result of $v_{2}$ - $v_{3}$ correlation within each centrality.
$v_{3}$ - $v_{2}$ inclusive correlation in 5% centrality intervals.
$v_{3}$ - $v_{2}$ correlation for various q3 bins within each centrality.
$v_{3}$ - $v_{2}$ inclusive correlation in 5% centrality intervals.
$v_{3}$ - $v_{2}$ correlation for various q3 bins within each centrality.
$v_{3}$ - $v_{2}$ inclusive correlation in 5% centrality intervals.
$v_{3}$ - $v_{2}$ correlation for various q3 bins within each centrality.
$v_{3}$ - $v_{2}$ inclusive correlation in 5% centrality intervals.
$v_{3}$ - $v_{2}$ correlation for various q3 bins within each centrality.
$v_{2}$ - $v_{4}$ inclusive correlation in 5% centrality intervals.
$v_{2}$ - $v_{4}$ correlation for various q2 bins within each centrality.
$v_{2}$ - $v_{4}$ inclusive correlation in 5% centrality intervals.
$v_{2}$ - $v_{4}$ correlation for various q2 bins within each centrality.
$v_{2}$ - $v_{4}$ inclusive correlation in 5% centrality intervals.
$v_{2}$ - $v_{4}$ correlation for various q2 bins within each centrality.
$v_{2}$ - $v_{4}$ inclusive correlation in 5% centrality intervals.
$v_{2}$ - $v_{4}$ correlation for various q2 bins within each centrality.
$v_{3}$ - $v_{4}$ inclusive correlation in 5% centrality intervals.
$v_{3}$ - $v_{4}$ correlation within each centrality.
$v_{3}$ - $v_{4}$ inclusive correlation in 5% centrality intervals.
$v_{3}$ - $v_{4}$ correlation within each centrality.
$v_4$ decomposed into linear and nonlinear contributions based on q2 event-shape selection.
$v_4$ decomposed into linear and nonlinear contributions based on q2 event-shape selection.
$v_4$ decomposed into linear and nonlinear contributions based on q2 event-shape selection.
$v_4$ decomposed into linear and nonlinear contributions based on q2 event-shape selection.
$v_4$ decomposed into linear and nonlinear contributions based on q2 event-shape selection.
$v_5$ decomposed into linear and nonlinear contributions based on q2 event-shape selection.
$v_5$ decomposed into linear and nonlinear contributions based on q3 event-shape selection.
RMS eccentricity scaled v_n.
RMS eccentricity scaled v_n.
$v_{2}$ - $v_{5}$ inclusive correlation in 5% centrality intervals.
$v_{2}$ - $v_{5}$ correlation for various q2 bins within each centrality.
$v_{3}$ - $v_{5}$ inclusive correlation in 5% centrality intervals.
$v_{3}$ - $v_{5}$ correlation for various q2 bins within each centrality.
Charged-particle spectra obtained in 0.15 nb${}^{-1}$ of Pb+Pb interactions at $\sqrt{{s}_\mathsf{{NN}}}=2.76$TeV and 4.2 pb${}^{-1}$ of pp interactions at $\sqrt{s}=2.76$ TeV with the ATLAS detector at the LHC are presented in a wide transverse momentum ($0.5 < p_{\mathrm{T}} < 150$ GeV) and pseudorapidity ($|\eta|<2$) range. For Pb+Pb collisions, the spectra are presented as a function of collision centrality, which is determined by the response of the forward calorimeter located on both sides of the interaction point. The nuclear modification factors $R_{\mathrm{AA}}$ and $R_{\mathrm{CP}}$ are presented in detail as function of centrality, $p_{\mathrm{T}}$ and $\eta$. They show a distinct $p_{\mathrm{T}}$-dependence with a pronounced minimum at about 7 GeV. Above 60 GeV, $R_{\mathrm{AA}}$ is consistent with a plateau at a centrality-dependent value, within the uncertainties. The value is $0.55\pm0.01(stat.)\pm0.04(syst.)$ in the most central collisions. The $R_{\mathrm{AA}}$ distribution is consistent with flat $|\eta|$ dependence over the whole transverse momentum range in all centrality classes.
Raa as a function of <Npart>.
Raa as a function of <Npart>.
Raa as a function of <Npart>.
Raa as a function of <Npart>.
Charged-particle spectra in different eta intervals for Pb+Pb.
Charged-particle spectra in different eta intervals for Pb+Pb (not shown in Fig. 17).
Charged-particle spectra in different eta intervals for Pb+Pb.
Charged-particle spectra in different eta intervals for Pb+Pb (not shown in Fig. 17).
Charged-particle spectra in different eta intervals for Pb+Pb.
Charged-particle spectra in different eta intervals for Pb+Pb (not shown in Fig. 17).
Charged-particle spectra in different eta intervals for Pb+Pb.
Charged-particle spectra in different eta intervals for Pb+Pb.
Charged-particle spectra in different eta intervals for Pb+Pb.
Charged-particle spectra in different eta intervals for Pb+Pb (not shown in Fig. 17).
Charged-particle spectra in different eta intervals for Pb+Pb.
Charged-particle spectra in different eta intervals for Pb+Pb (not shown in Fig. 17).
Charged-particle spectra in different eta intervals for Pb+Pb.
Charged-particle spectra in different eta intervals for Pb+Pb (not shown in Fig. 17).
Charged-particle spectra in different eta intervals for Pb+Pb.
Charged-particle spectra in different eta intervals for Pb+Pb.
Charged-particle spectra in different eta intervals for Pb+Pb.
Charged-particle spectra in different eta intervals for Pb+Pb (not shown in Fig. 17).
Charged-particle spectra in different eta intervals for Pb+Pb.
Charged-particle spectra in different eta intervals for Pb+Pb (not shown in Fig. 17).
Charged-particle spectra in different eta intervals for Pb+Pb.
Charged-particle spectra in different eta intervals for Pb+Pb (not shown in Fig. 17).
Charged-particle spectra in different eta intervals for Pb+Pb.
Charged-particle spectra in different eta intervals for Pb+Pb.
Charged-particle spectra in different eta intervals for Pb+Pb.
Charged-particle spectra in different eta intervals for Pb+Pb (not shown in Fig. 17).
Charged-particle spectra in different eta intervals for Pb+Pb.
Charged-particle spectra in different eta intervals for Pb+Pb (not shown in Fig. 17).
Charged-particle spectra in different eta intervals for Pb+Pb.
Charged-particle spectra in different eta intervals for Pb+Pb (not shown in Fig. 17).
Charged-particle spectra in different eta intervals for Pb+Pb.
Charged-particle spectra in different eta intervals for Pb+Pb.
Raa in different eta intervals.
Raa in different eta intervals (not shown in Fig. 18).
Raa in different eta intervals.
Raa in different eta intervals (not shown in Fig. 18).
Raa in different eta intervals.
Raa in different eta intervals (not shown in Fig. 18).
Raa in different eta intervals.
Raa in different eta intervals.
Raa in different eta intervals.
Raa in different eta intervals (not shown in Fig. 18).
Raa in different eta intervals.
Raa in different eta intervals (not shown in Fig. 18).
Raa in different eta intervals.
Raa in different eta intervals (not shown in Fig. 18).
Raa in different eta intervals.
Raa in different eta intervals.
Raa in different eta intervals.
Raa in different eta intervals (not shown in Fig. 18).
Raa in different eta intervals.
Raa in different eta intervals (not shown in Fig. 18).
Raa in different eta intervals.
Raa in different eta intervals (not shown in Fig. 18).
Raa in different eta intervals.
Raa in different eta intervals.
Raa in different eta intervals.
Raa in different eta intervals (not shown in Fig. 18).
Raa in different eta intervals.
Raa in different eta intervals (not shown in Fig. 18).
Raa in different eta intervals.
Raa in different eta intervals (not shown in Fig. 18).
Raa in different eta intervals.
Raa in different eta intervals.
Measurements of charged-particle fragmentation functions of jets produced in ultra-relativistic nuclear collisions can provide insight into the modification of parton showers in the hot, dense medium created in the collisions. ATLAS has measured jets in $\sqrt{s_{NN}} = 2.76$ TeV Pb+Pb collisions at the LHC using a data set recorded in 2011 with an integrated luminosity of 0.14 nb$^{-1}$. Jets were reconstructed using the anti-$k_{t}$ algorithm with distance parameter values $R$ = 0.2, 0.3, and 0.4. Distributions of charged-particle transverse momentum and longitudinal momentum fraction are reported for seven bins in collision centrality for $R=0.4$ jets with $p_{{T}}^{\mathrm{jet}}> 100$ GeV. Commensurate minimum $p_{\mathrm{T}}$ values are used for the other radii. Ratios of fragment distributions in each centrality bin to those measured in the most peripheral bin are presented. These ratios show a reduction of fragment yield in central collisions relative to peripheral collisions at intermediate $z$ values, $0.04 \lesssim z \lesssim 0.2$ and an enhancement in fragment yield for $z \lesssim 0.04$. A smaller, less significant enhancement is observed at large $z$ and large $p_{\mathrm{T}}$ in central collisions.
The distributions of event-by-event harmonic flow coefficients v_n for n=2-4 are measured in sqrt(s_NN)=2.76 TeV Pb+Pb collisions using the ATLAS detector at the LHC. The measurements are performed using charged particles with transverse momentum pT> 0.5 GeV and in the pseudorapidity range |eta|<2.5 in a dataset of approximately 7 ub^-1 recorded in 2010. The shapes of the v_n distributions are described by a two-dimensional Gaussian function for the underlying flow vector in central collisions for v_2 and over most of the measured centrality range for v_3 and v_4. Significant deviations from this function are observed for v_2 in mid-central and peripheral collisions, and a small deviation is observed for v_3 in mid-central collisions. It is shown that the commonly used multi-particle cumulants are insensitive to the deviations for v_2. The v_n distributions are also measured independently for charged particles with 0.5<pT<1 GeV and pT>1 GeV. When these distributions are rescaled to the same mean values, the adjusted shapes are found to be nearly the same for these two pT ranges. The v_n distributions are compared with the eccentricity distributions from two models for the initial collision geometry: a Glauber model and a model that includes corrections to the initial geometry due to gluon saturation effects. Both models fail to describe the experimental data consistently over most of the measured centrality range.
The relationship between centrality intervals and MEAN(Npart) estimated from the Glauber model.
The MEAN(Npart) dependence of MEAN(V2) for three pT ranges together with the total systematic uncertainties.
The MEAN(Npart) dependence of SIGMA(V2) for three pT ranges together with the total systematic uncertainties.
The MEAN(Npart) dependence of SIGMA(V2)/MEAN(V2) for three pT ranges together with the total systematic uncertainties.
The MEAN(Npart) dependence of MEAN(V3) for three pT ranges together with the total systematic uncertainties.
The MEAN(Npart) dependence of SIGMA(V3) for three pT ranges together with the total systematic uncertainties.
The MEAN(Npart) dependence of SIGMA(V3)/MEAN(V3) for three pT ranges together with the total systematic uncertainties.
The MEAN(Npart) dependence of MEAN(V4) for three pT ranges together with the total systematic uncertainties.
The MEAN(Npart) dependence of SIGMA(V4) for three pT ranges together with the total systematic uncertainties.
The MEAN(Npart) dependence of SIGMA(V4)/MEAN(V4) for three pT ranges together with the total systematic uncertainties.
Eccentricity curves for EPSILON2 in Figure 12.
Eccentricity curves for EPSILON3 in Figure 12.
Eccentricity curves for EPSILON4 in Figure 12.
Comparison of MEAN(V2) and SQRT(MEAN(V2**2)), derived from the EbyE V2 distributions, with the V2(EP), for charged particles in the pT > 0.5 GeV range.
The ratios of SQRT(MEAN(V2**2)) and V2(EP) to MEAN(V2), for charged particles in the pT > 0.5 GeV range.
Comparison of MEAN(V3) and SQRT(MEAN(V3**2)), derived from the EbyE V3 distributions, with the V3(EP), for charged particles in the pT > 0.5 GeV range.
The ratios of SQRT(MEAN(V3**2)) and V3(EP) to MEAN(V3), for charged particles in the pT > 0.5 GeV range.
Comparison of MEAN(V4) and SQRT(MEAN(V4**2)), derived from the EbyE V4 distributions, with the V4(EP), for charged particles in the pT > 0.5 GeV range.
The ratios of SQRT(MEAN(V4**2)) and V4(EP) to MEAN(V4), for charged particles in the pT > 0.5 GeV range.
Comparison of MEAN(V2) and SQRT(MEAN(V2**2)), derived from the EbyE V2 distributions, with the V2(EP), for charged particles in the 0.5 < pT < 1 GeV range.
The ratios of SQRT(MEAN(V2**2)) and V2(EP) to MEAN(V2), for charged particles in the 0.5 < pT < 1 GeV range.
Comparison of MEAN(V3) and SQRT(MEAN(V3**2)), derived from the EbyE V3 distributions, with the V3(EP), for charged particles in the 0.5 < pT < 1 GeV range.
The ratios of SQRT(MEAN(V3**2)) and V3(EP) to MEAN(V3), for charged particles in the 0.5 < pT < 1 GeV range.
Comparison of MEAN(V4) and SQRT(MEAN(V4**2)), derived from the EbyE V4 distributions, with the V4(EP), for charged particles in the 0.5 < pT < 1 GeV range.
The ratios of SQRT(MEAN(V4**2)) and V4(EP) to MEAN(V4), for charged particles in the 0.5 < pT < 1 GeV range.
Comparison of MEAN(V2) and SQRT(MEAN(V2**2)), derived from the EbyE V2 distributions, with the V2(EP), for charged particles in the pT > 1 GeV range.
The ratios of SQRT(MEAN(V2**2)) and V2(EP) to MEAN(V2), for charged particles in the pT > 1 GeV range.
Comparison of MEAN(V3) and SQRT(MEAN(V3**2)), derived from the EbyE V3 distributions, with the V3(EP), for charged particles in the pT > 1 GeV range.
The ratios of SQRT(MEAN(V3**2)) and V3(EP) to MEAN(V3), for charged particles in the pT > 1 GeV range.
Comparison of MEAN(V4) and SQRT(MEAN(V4**2)), derived from the EbyE V4 distributions, with the V4(EP), for charged particles in the pT > 1 GeV range.
The ratios of SQRT(MEAN(V4**2)) and V4(EP) to MEAN(V4), for charged particles in the pT > 1 GeV range.
Bessel-Gaussian fit parameters from Eq. (1.4) and total errors.
The dependence of MEAN(V2) and V2(RP) on MEAN(Npart).
The dependence of SIGMA(V2) and DELTA(V2) on MEAN(Npart).
The dependence of SIGMA(V2) / MEAN(V2) and DELTA(V2) / V2(RP) on MEAN(Npart).
Comparison of the V2(RP) obtained from the Bessel-Gaussian fit of the V2 distributions with the values for two-particle (V2(calc){2}), four-particle (V2(calc){4}), six-particle (V2(calc){6}) and eight-particle (V2(calc){8}) cumulants calculated directly from the unfolded V2 distributions.
The ratios of the four-particle (V2(calc){4}), six-particle (V2(calc){6}) and eight-particle (V2(calc){8}) cumulants to the fit results (V2(RP)), with the total uncertainties.
The ratios of the six-particle (V2(calc){6}) and eight-particle (V2(calc){8}) cumulants to the four-particle (V2(calc){4}) cumulants, with the total uncertainties.
Comparison of the V3(RP) obtained from the Bessel-Gaussian fit of the V3 distributions with the values for two-particle (V3(calc){2}), four-particle (V3(calc){4}), six-particle (V3(calc){6}) and eight-particle (V3(calc){8}) cumulants calculated directly from the unfolded V3 distributions.
The ratios of the four-particle (V3(calc){4}), six-particle (V3(calc){6}) and eight-particle (V3(calc){8}) cumulants to the fit results (V3(RP)), with the total uncertainties.
The ratios of the six-particle (V3(calc){6}) and eight-particle (V3(calc){8}) cumulants to the four-particle (V3(calc){4}) cumulants, with the total uncertainties.
The standard deviation (SIGMA(V2)), the width obtained from Bessel-Gaussian function (DELTA(V2)), the width F1 = SQRT( ( V2(calc){2}**2 - V2(calc){4}**2 ) / 2 ) estimated from the two-particle cumulant (V2(calc){2}) and four-particle cumulant (V2(calc){4}), where these cumulants are calculated analytically via Eq. (5.3) from the V2 distribution.
Various estimates of the relative fluctuations given as SIGMA(V2) / MEAN(V2), DELTA(V2) / V2(RP), F2 = SQRT( ( V2(calc){2}**2 - V2(calc){4}**2) / ( 2*V2(calc){4}**2 ) ) and F3 = SQRT( ( V2(calc){2}**2 - V2(calc){4}**2) / ( V2(calc){2}**2 + V2(calc){4}**2 ) ).
Comparison in 0.5 < pT < 1 GeV of the V2(RP) obtained from the Bessel-Gaussian fit of the V2 distributions with the values for two-particle (V2(calc){2}), four-particle (V2(calc){4}), six-particle (V2(calc){6}) and eight-particle (V2(calc){8}) cumulants calculated directly from the unfolded V2 distributions.
The ratios for 0.5 < pT < 1 GeV of the four-particle (V2(calc){4}), six-particle (V2(calc){6}) and eight-particle (V2(calc){8}) cumulants to the fit results (V2(RP)), with the total uncertainties.
The ratios for 0.5 < pT < 1 GeV of the six-particle (V2(calc){6}) and eight-particle (V2(calc){8}) cumulants to the four-particle (V2(calc){4}) cumulants, with the total uncertainties.
Comparison in pT > 1 GeV of the V2(RP) obtained from the Bessel-Gaussian fit of the V2 distributions with the values for two-particle (V2(calc){2}), four-particle (V2(calc){4}), six-particle (V2(calc){6}) and eight-particle (V2(calc){8}) cumulants calculated directly from the unfolded V2 distributions.
The ratios for pT > 1 GeV of the four-particle (V2(calc){4}), six-particle (V2(calc){6}) and eight-particle (V2(calc){8}) cumulants to the fit results (V2(RP)), with the total uncertainties.
The ratios for pT > 1 GeV of the six-particle (V2(calc){6}) and eight-particle (V2(calc){8}) cumulants to the four-particle (V2(calc){4}) cumulants, with the total uncertainties.
The values of V2(RP) and V2(RP,obs) obtained from the Bessel-Gaussian fits to the V2 and V2(obs) distributions, with the statistical uncertainties.
The values of DELTA(V2) and DELTA(V2,obs) obtained from the Bessel-Gaussian fits to the V2 and V2(obs) distributions, with the statistical uncertainties.
.
.
.
.
.
.
.
.
.
.
.
.
.
Measurements of the azimuthal anisotropy in lead-lead collisions at $\sqrt{s_\mathrm{NN}} = 5.02$ TeV are presented using a data sample corresponding to 0.49 $\mathrm{nb}^{-1}$ integrated luminosity collected by the ATLAS experiment at the LHC in 2015. The recorded minimum-bias sample is enhanced by triggers for "ultra-central" collisions, providing an opportunity to perform detailed study of flow harmonics in the regime where the initial state is dominated by fluctuations. The anisotropy of the charged-particle azimuthal angle distributions is characterized by the Fourier coefficients, $v_{2}-v_{7}$, which are measured using the two-particle correlation, scalar-product and event-plane methods. The goal of the paper is to provide measurements of the differential as well as integrated flow harmonics $v_{n}$ over wide ranges of the transverse momentum, 0.5 $
The V2 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-0.1%
The V2 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-1%
The V2 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-5%
The V2 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 5-10%
The V2 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 10-20%
The V2 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 20-30%
The V2 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 30-40%
The V2 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 40-50%
The V2 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 50-60%
The V2 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 60-70%
The V2 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 70-80%
The V3 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-0.1%
The V3 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-1%
The V3 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-5%
The V3 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 5-10%
The V3 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 10-20%
The V3 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 20-30%
The V3 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 30-40%
The V3 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 40-50%
The V3 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 50-60%
The V3 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 60-70%
The V3 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 70-80%
The V4 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-0.1%
The V4 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-1%
The V4 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-5%
The V4 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 5-10%
The V4 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 10-20%
The V4 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 20-30%
The V4 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 30-40%
The V4 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 40-50%
The V4 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 50-60%
The V4 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 60-70%
The V4 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 70-80%
The V5 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-0.1%
The V5 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-1%
The V5 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-5%
The V5 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 5-10%
The V5 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 10-20%
The V5 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 20-30%
The V5 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 30-40%
The V5 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 40-50%
The V5 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 50-60%
The V5 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 60-70%
The V5 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 70-80%
The V6 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-5%
The V6 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 5-10%
The V6 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 10-20%
The V6 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 20-30%
The V6 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 30-40%
The V6 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 40-50%
The V6 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 50-60%
The V6 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 60-70%
The V6 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 70-80%
The V7 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-5%
The V7 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 5-10%
The V7 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 10-20%
The V7 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 20-30%
The V7 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 30-40%
The V7 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 40-50%
The V7 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 50-60%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 0-5%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 5-10%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 10-20%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 20-30%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 30-40%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 40-50%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 50-60%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 60-70%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 70-80%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 0-5%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 5-10%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 10-20%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 20-30%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 30-40%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 40-50%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 50-60%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 60-70%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 70-80%
The V4 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 0-5%
The V4 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 5-10%
The V4 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 10-20%
The V4 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 20-30%
The V4 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 30-40%
The V4 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 40-50%
The V4 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 50-60%
The V4 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 60-70%
The V4 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 70-80%
The V5 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 0-5%
The V5 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 5-10%
The V5 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 10-20%
The V5 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 20-30%
The V5 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 30-40%
The V5 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 40-50%
The V5 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 50-60%
The V5 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 60-70%
The V6 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 0-5%
The V6 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 5-10%
The V6 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 10-20%
The V6 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 20-30%
The V6 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 30-40%
The V6 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 40-50%
The V6 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 50-60%
The V6 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 60-70%
The ratio of V2{SP} over V2{EP} as a funtion of transverse momentum in centrality bin 0-5%
The ratio of V2{SP} over V2{EP} as a funtion of transverse momentum in centrality bin 20-30%
The ratio of V2{SP} over V2{EP} as a funtion of transverse momentum in centrality bin 40-50%
The ratio of V3{SP} over V3{EP} as a funtion of transverse momentum in centrality bin 0-5%
The ratio of V3{SP} over V3{EP} as a funtion of transverse momentum in centrality bin 20-30%
The ratio of V3{SP} over V3{EP} as a funtion of transverse momentum in centrality bin 40-50%
The ratio of V4{SP} over V4{EP} as a funtion of transverse momentum in centrality bin 0-5%
The ratio of V4{SP} over V4{EP} as a funtion of transverse momentum in centrality bin 20-30%
The ratio of V4{SP} over V4{EP} as a funtion of transverse momentum in centrality bin 40-50%
The ratio of V5{SP} over V5{EP} as a funtion of transverse momentum in centrality bin 0-5%
The ratio of V5{SP} over V5{EP} as a funtion of transverse momentum in centrality bin 20-30%
The ratio of V5{SP} over V5{EP} as a funtion of transverse momentum in centrality bin 40-50%
The ratio of V6{SP} over V6{EP} as a funtion of transverse momentum in centrality bin 0-5%
The ratio of V6{SP} over V6{EP} as a funtion of transverse momentum in centrality bin 20-30%
The ratio of V6{SP} over V6{EP} as a funtion of transverse momentum in centrality bin 40-50%
The ratio of V2{SP} over V2{EP} as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The ratio of V3{SP} over V3{EP} as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The ratio of V4{SP} over V4{EP} as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The ratio of V5{SP} over V5{EP} as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The ratio of V6{SP} over V6{EP} as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The ratio of V2{SP} over V2{2PC} as a funtion of transverse momentum in centrality bin 0-5%
The ratio of V2{SP} over V2{2PC} as a funtion of transverse momentum in centrality bin 20-30%
The ratio of V2{SP} over V2{2PC} as a funtion of transverse momentum in centrality bin 40-50%
The ratio of V3{SP} over V3{2PC} as a funtion of transverse momentum in centrality bin 0-5%
The ratio of V3{SP} over V3{2PC} as a funtion of transverse momentum in centrality bin 20-30%
The ratio of V3{SP} over V3{2PC} as a funtion of transverse momentum in centrality bin 40-50%
The ratio of V4{SP} over V4{2PC} as a funtion of transverse momentum in centrality bin 0-5%
The ratio of V4{SP} over V4{2PC} as a funtion of transverse momentum in centrality bin 20-30%
The ratio of V4{SP} over V4{2PC} as a funtion of transverse momentum in centrality bin 40-50%
The ratio of V5{SP} over V5{2PC} as a funtion of transverse momentum in centrality bin 0-5%
The ratio of V5{SP} over V5{2PC} as a funtion of transverse momentum in centrality bin 20-30%
The ratio of V5{SP} over V5{2PC} as a funtion of transverse momentum in centrality bin 40-50%
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-5%. PT binning matched to RUN1.
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 20-30%. PT binning matched to RUN1.
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 40-50%. PT binning matched to RUN1.
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-5%. PT binning matched to RUN1.
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 20-30%. PT binning matched to RUN1.
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 40-50%. PT binning matched to RUN1.
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-5%. PT binning matched to RUN1.
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 20-30%. PT binning matched to RUN1.
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 40-50%. PT binning matched to RUN1.
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-5%. PT binning matched to RUN1.
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 20-30%. PT binning matched to RUN1.
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 40-50%. PT binning matched to RUN1.
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-5%. PT binning matched to RUN1.
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 20-30%. PT binning matched to RUN1.
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 40-50%. PT binning matched to RUN1.
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-0.1%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-5%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 10-20%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 30-40%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 60-70%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-0.1%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-5%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 10-20%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 30-40%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 60-70%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-0.1%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-5%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 10-20%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 30-40%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 60-70%
The V5 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-0.1%
The V5 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-5%
The V5 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 10-20%
The V5 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 30-40%
The V5 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 60-70%
The V6 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-5%
The V6 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 10-20%
The V6 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 30-40%
The V6 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 60-70%
The V7 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-5%
The V7 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 10-20%
The V7 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 30-40%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-0.1%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-5%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 10-20%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 30-40%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 60-70%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-0.1%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-5%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 10-20%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 30-40%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 60-70%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-0.1%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-5%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 10-20%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 30-40%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 60-70%
The V5 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-0.1%
The V5 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-5%
The V5 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 10-20%
The V5 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 30-40%
The V5 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 60-70%
The V6 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-5%
The V6 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 10-20%
The V6 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 30-40%
The V6 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 60-70%
The V7 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-5%
The V7 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 10-20%
The V7 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 30-40%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 0-0.1%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 0-5%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 10-20%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 30-40%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 60-70%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 0-0.1%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 0-5%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 10-20%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 30-40%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 0-0.1%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 0-5%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 10-20%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 30-40%
The V2 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 0.8 GeV
The V2 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.8 < PT < 1 GeV
The V2 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 1 < PT < 2 GeV
The V2 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 2 < PT < 4 GeV
The V2 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 4 < PT < 8 GeV
The V2 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 8 < PT < 60 GeV
The V2 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The V3 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 0.8 GeV
The V3 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.8 < PT < 1 GeV
The V3 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 1 < PT < 2 GeV
The V3 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 2 < PT < 4 GeV
The V3 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 4 < PT < 8 GeV
The V3 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 8 < PT < 60 GeV
The V3 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The V4 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 0.8 GeV
The V4 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.8 < PT < 1 GeV
The V4 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 1 < PT < 2 GeV
The V4 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 2 < PT < 4 GeV
The V4 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 4 < PT < 8 GeV
The V4 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 8 < PT < 60 GeV
The V4 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The V5 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 0.8 GeV
The V5 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.8 < PT < 1 GeV
The V5 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 1 < PT < 2 GeV
The V5 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 2 < PT < 4 GeV
The V5 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 4 < PT < 8 GeV
The V5 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 8 < PT < 60 GeV
The V5 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The V6 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 0.8 GeV
The V6 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.8 < PT < 1 GeV
The V6 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 1 < PT < 2 GeV
The V6 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 2 < PT < 4 GeV
The V6 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 4 < PT < 8 GeV
The V6 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 8 < PT < 60 GeV
The V6 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The V7 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 0.8 GeV
The V7 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.8 < PT < 1 GeV
The V7 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 1 < PT < 2 GeV
The V7 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 2 < PT < 4 GeV
The V7 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 4 < PT < 8 GeV
The V7 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 8 < PT < 60 GeV
The V7 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 0-5%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 10-15%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 20-25%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 30-35%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 40-45%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 50-55%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 0-5%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 10-15%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 20-25%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 30-35%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 40-45%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 50-55%
The scaled-V2(PT) measured with the two particle correlation method in centrality bin 0-5%
The scaled-V2(PT) measured with the two particle correlation method in centrality bin 10-15%
The scaled-V2(PT) measured with the two particle correlation method in centrality bin 20-25%
The scaled-V2(PT) measured with the two particle correlation method in centrality bin 30-35%
The scaled-V2(PT) measured with the two particle correlation method in centrality bin 40-45%
The scaled-V2(PT) measured with the two particle correlation method in centrality bin 50-55%
The scaled-V3(PT) measured with the two particle correlation method in centrality bin 0-5%
The scaled-V3(PT) measured with the two particle correlation method in centrality bin 10-15%
The scaled-V3(PT) measured with the two particle correlation method in centrality bin 20-25%
The scaled-V3(PT) measured with the two particle correlation method in centrality bin 30-35%
The scaled-V3(PT) measured with the two particle correlation method in centrality bin 40-45%
The scaled-V3(PT) measured with the two particle correlation method in centrality bin 50-55%
The PT scale factor for V2(PT) as a funtion of collision centrality
The PT scale factor for V3(PT) as a funtion of collision centrality
The V2 scale factor as a funtion of collision centrality
The V3 scale factor as a funtion of collision centrality
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-0.1%
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-1%
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-5%
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 5-10%
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 10-20%
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 20-30%
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 30-40%
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 40-50%
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 50-60%
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 60-70%
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 70-80%
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-0.1%
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-1%
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-5%
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 5-10%
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 10-20%
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 20-30%
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 30-40%
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 40-50%
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 50-60%
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 60-70%
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 70-80%
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-0.1%
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-1%
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-5%
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 5-10%
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 10-20%
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 20-30%
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 30-40%
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 40-50%
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 50-60%
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 60-70%
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 70-80%
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-0.1%
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-1%
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-5%
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 5-10%
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 10-20%
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 20-30%
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 30-40%
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 40-50%
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 50-60%
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 60-70%
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 70-80%
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-5%
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 5-10%
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 10-20%
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 20-30%
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 30-40%
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 40-50%
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 50-60%
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 60-70%
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 70-80%
The V7 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-5%
The V7 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 5-10%
The V7 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 10-20%
The V7 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 20-30%
The V7 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 30-40%
The V7 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 40-50%
The V7 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 50-60%
The V2 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-0.1%
The V2 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-5%
The V2 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 10-20%
The V2 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 30-40%
The V2 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 60-70%
The V3 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-0.1%
The V3 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-5%
The V3 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 10-20%
The V3 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 30-40%
The V3 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 60-70%
The V4 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-0.1%
The V4 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-5%
The V4 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 10-20%
The V4 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 30-40%
The V4 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 60-70%
The V5 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-0.1%
The V5 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-5%
The V5 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 10-20%
The V5 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 30-40%
The V5 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 60-70%
The V6 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-5%
The V6 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 10-20%
The V6 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 30-40%
The V6 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 60-70%
The V7 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-5%
The V7 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 10-20%
The V7 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 30-40%
The V2 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-0.1%
The V2 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-5%
The V2 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 10-20%
The V2 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 30-40%
The V2 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 60-70%
The V3 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-0.1%
The V3 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-5%
The V3 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 10-20%
The V3 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 30-40%
The V3 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 60-70%
The V4 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-0.1%
The V4 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-5%
The V4 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 10-20%
The V4 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 30-40%
The V4 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 60-70%
The V5 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-0.1%
The V5 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-5%
The V5 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 10-20%
The V5 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 30-40%
The V5 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 60-70%
The V6 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-5%
The V6 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 10-20%
The V6 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 30-40%
The V6 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 60-70%
The V7 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-5%
The V7 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 10-20%
The V7 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 30-40%
The V2 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 0-0.1%
The V2 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 0-5%
The V2 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 10-20%
The V2 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 30-40%
The V2 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 60-70%
The V3 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 0-0.1%
The V3 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 0-5%
The V3 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 10-20%
The V3 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 30-40%
The V4 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 0-0.1%
The V4 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 0-5%
The V4 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 10-20%
The V4 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 30-40%
The V2 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 0.8 GeV
The V2 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.8 < PT < 1 GeV
The V2 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 1 < PT < 2 GeV
The V2 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 2 < PT < 4 GeV
The V2 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 4 < PT < 8 GeV
The V2 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 8 < PT < 60 GeV
The V2 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The V3 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 0.8 GeV
The V3 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.8 < PT < 1 GeV
The V3 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 1 < PT < 2 GeV
The V3 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 2 < PT < 4 GeV
The V3 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 4 < PT < 8 GeV
The V3 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 8 < PT < 60 GeV
The V3 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The V4 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 0.8 GeV
The V4 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.8 < PT < 1 GeV
The V4 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 1 < PT < 2 GeV
The V4 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 2 < PT < 4 GeV
The V4 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 4 < PT < 8 GeV
The V4 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 8 < PT < 60 GeV
The V4 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The V5 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 0.8 GeV
The V5 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.8 < PT < 1 GeV
The V5 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 1 < PT < 2 GeV
The V5 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 2 < PT < 4 GeV
The V5 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 4 < PT < 8 GeV
The V5 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 8 < PT < 60 GeV
The V5 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The V6 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 0.8 GeV
The V6 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.8 < PT < 1 GeV
The V6 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 1 < PT < 2 GeV
The V6 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 2 < PT < 4 GeV
The V6 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 4 < PT < 8 GeV
The V6 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 8 < PT < 60 GeV
The V6 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The V7 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 0.8 GeV
The V7 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.8 < PT < 1 GeV
The V7 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 1 < PT < 2 GeV
The V7 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 2 < PT < 4 GeV
The V7 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 4 < PT < 8 GeV
The V7 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 8 < PT < 60 GeV
The V7 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
This paper describes the measurement of elliptic flow of charged particles in lead-lead collisions at sqrt(s_NN) = 2.76 TeV using the ATLAS detector at the Large Hadron Collider (LHC). The results are based on an integrated luminosity of approximately 7 ub^-1. Elliptic flow is measured over a wide region in pseudorapidity, |eta| < 2.5, and over a broad range in transverse momentum, 0.5 < p_T < 20 GeV. The elliptic flow parameter v_2 is obtained by correlating individual tracks with the event plane measured using energy deposited in the forward calorimeters. As a function of transverse momentum, v_2(p_T) reaches a maximum at p_T of about 3 GeV, then decreases and becomes weakly dependent on p_T above 7 - 8 GeV. Over the measured pseudorapidity region, v_2 is found to be approximately independent of |eta| for all collision centralities and particle transverse momenta, something not observed in lower energy collisions. The results are discussed in the context of previous measurements at lower collision energies, as well as recent results from the LHC.
v2(pT) for centrality interval 0-10% and |eta| <1.
v2(pT) for centrality interval 10-20% and |eta| <1.
v2(pT) for centrality interval 20-30% and |eta| <1.
v2(pT) for centrality interval 30-40% and |eta| <1.
v2(pT) for centrality interval 40-50% and |eta| <1.
v2(pT) for centrality interval 50-60% and |eta| <1.
v2(pT) for centrality interval 60-70% and |eta| <1.
v2(pT) for centrality interval 70-80% and |eta| <1.
v2(pT) for centrality interval 0-10% and 1< |eta| <2.
v2(pT) for centrality interval 10-20% and 1< |eta| <2.
v2(pT) for centrality interval 20-30% and 1< |eta| <2.
v2(pT) for centrality interval 30-40% and 1< |eta| <2.
v2(pT) for centrality interval 40-50% and 1< |eta| <2.
v2(pT) for centrality interval 50-60% and 1< |eta| <2.
v2(pT) for centrality interval 60-70% and 1< |eta| <2.
v2(pT) for centrality interval 70-80% and 1< |eta| <2.
v2(pT) for centrality interval 0-10% and 2< |eta| <2.5.
v2(pT) for centrality interval 10-20% and 2< |eta| <2.5.
v2(pT) for centrality interval 20-30% and 2< |eta| <2.5.
v2(pT) for centrality interval 30-40% and 2< |eta| <2.5.
v2(pT) for centrality interval 40-50% and 2< |eta| <2.5.
v2(pT) for centrality interval 50-60% and 2< |eta| <2.5.
v2(pT) for centrality interval 60-70% and 2< |eta| <2.5.
v2(pT) for centrality interval 70-80% and 2< |eta| <2.5.
v2(eta) for centrality interval 0-10% and 0.5< pT <0.7 GeV.
v2(eta) for centrality interval 10-20% and 0.5< pT <0.7 GeV.
v2(eta) for centrality interval 20-30% and 0.5< pT <0.7 GeV.
v2(eta) for centrality interval 30-40% and 0.5< pT <0.7 GeV.
v2(eta) for centrality interval 40-50% and 0.5< pT <0.7 GeV.
v2(eta) for centrality interval 50-60% and 0.5< pT <0.7 GeV.
v2(eta) for centrality interval 60-70% and 0.5< pT <0.7 GeV.
v2(eta) for centrality interval 70-80% and 0.5< pT <0.7 GeV.
v2(eta) for centrality interval 0-10% and 0.8< pT <1.2 GeV.
v2(eta) for centrality interval 10-20% and 0.8< pT <1.2 GeV.
v2(eta) for centrality interval 20-30% and 0.8< pT <1.2 GeV.
v2(eta) for centrality interval 30-40% and 0.8< pT <1.2 GeV.
v2(eta) for centrality interval 40-50% and 0.8< pT <1.2 GeV.
v2(eta) for centrality interval 50-60% and 0.8< pT <1.2 GeV.
v2(eta) for centrality interval 60-70% and 0.8< pT <1.2 GeV.
v2(eta) for centrality interval 70-80% and 0.8< pT <1.2 GeV.
v2(eta) for centrality interval 0-10% and 2< pT <4 GeV.
v2(eta) for centrality interval 10-20% and 2< pT <4 GeV.
v2(eta) for centrality interval 20-30% and 2< pT <4 GeV.
v2(eta) for centrality interval 30-40% and 2< pT <4 GeV.
v2(eta) for centrality interval 40-50% and 2< pT <4 GeV.
v2(eta) for centrality interval 50-60% and 2< pT <4 GeV.
v2(eta) for centrality interval 60-70% and 2< pT <4 GeV.
v2(eta) for centrality interval 70-80% and 2< pT <4 GeV.
v2(eta) for centrality interval 0-10% and 4< pT <7 GeV.
v2(eta) for centrality interval 10-20% and 4< pT <7 GeV.
v2(eta) for centrality interval 20-30% and 4< pT <7 GeV.
v2(eta) for centrality interval 30-40% and 4< pT <7 GeV.
v2(eta) for centrality interval 40-50% and 4< pT <7 GeV.
v2(eta) for centrality interval 50-60% and 4< pT <7 GeV.
v2(eta) for centrality interval 60-70% and 4< pT <7 GeV.
v2(eta) for centrality interval 70-80% and 4< pT <7 GeV.
v2(eta) for centrality interval 0-10% and 9< pT <20 GeV.
v2(eta) for centrality interval 10-20% and 9< pT <20 GeV.
v2(eta) for centrality interval 20-30% and 9< pT <20 GeV.
v2(eta) for centrality interval 30-40% and 9< pT <20 GeV.
v2(eta) for centrality interval 40-50% and 9< pT <20 GeV.
v2(eta) for centrality interval 50-60% and 9< pT <20 GeV.
v2(eta) for centrality interval 60-70% and 9< pT <20 GeV.
v2(eta) for centrality interval 70-80% and 9< pT <20 GeV.
The ATLAS experiment at the LHC has measured the centrality dependence of charged particle pseudorapidity distributions over |eta| < 2 in lead-lead collisions at a nucleon-nucleon centre-of-mass energy of sqrt(s_NN) = 2.76 TeV. In order to include particles with transverse momentum as low as 30 MeV, the data were recorded with the central solenoid magnet off. Charged particles were reconstructed with two algorithms (2-point 'tracklets' and full tracks) using information from the pixel detector only. The lead-lead collision centrality was characterized by the total transverse energy in the forward calorimeter in the range 3.2 < |eta| < 4.9. Measurements are presented of the per-event charged particle density distribution, dN_ch/deta, and the average charged particle multiplicity in the pseudorapidity interval |eta|<0.5 in several intervals of collision centrality. The results are compared to previous mid-rapidity measurements at the LHC and RHIC. The variation of the mid-rapidity charged particle yield per colliding nucleon pair with the number of participants is consistent with the lower sqrt(s_NN) results. The shape of the dN_ch/deta distribution is found to be independent of centrality within the systematic uncertainties of the measurement.
The measured charged particle density distributions as a fuinction of pseudorapidity in the centrality regions 0-10, 10-20, 20-30 and 30-40 %.
The measured charged particle density distributions as a fuinction of pseudorapidity in the centrality regions 40-50, 50-60, 60-70 and 70-80 %.
Mean values of the charged particle multiplicities in the pseudorapidiy range -0.5-0.5 as a function of centrality. N(C=PART), the number of participating nucleons in the collision, is also shown, determined from the muliplicity and ET of the event, with which it has been shown to be strongly correlated.
The integrated elliptic flow of charged particles produced in Pb+Pb collisions at sqrt(s_NN)=2.76 TeV has been measured with the ATLAS detector using data collected at the Large Hadron Collider. The anisotropy parameter, v_2, was measured in the pseudorapidity range |eta| <= 2.5 with the event-plane method. In order to include tracks with very low transverse momentum pT, thus reducing the uncertainty in v_2 integrated over pT, a 1 mu b-1 data sample without a magnetic field in the tracking detectors is used. The centrality dependence of the integrated v_2 is compared to other measurements obtained with higher pT thresholds. A weak pseudorapidity dependence of the integrated elliptic flow is observed for central collisions, and a small decrease when moving away from mid-rapidity is observed only in peripheral collisions. The integrated v2 transformed to the rest frame of one of the colliding nuclei is compared to the lower-energy RHIC data.
Measurements of two-particle correlation functions and the first five azimuthal harmonics, $v_1$ to $v_5$, are presented, using 28 $\mathrm{nb}^{-1}$ of $p$+Pb collisions at a nucleon-nucleon center-of-mass energy of $\sqrt{s_{\mathrm{NN}}}=5.02$ TeV measured with the ATLAS detector at the LHC. Significant long-range "ridge-like" correlations are observed for pairs with small relative azimuthal angle ($|\Delta\phi|<\pi/3$) and back-to-back pairs ($|\Delta\phi| > 2\pi/3$) over the transverse momentum range $0.4 < p_{\rm T} < 12$ GeV and in different intervals of event activity. The event activity is defined by either the number of reconstructed tracks or the total transverse energy on the Pb-fragmentation side. The azimuthal structure of such long-range correlations is Fourier decomposed to obtain the harmonics $v_n$ as a function of $p_{\rm T}$ and event activity. The extracted $v_n$ values for $n=2$ to 5 decrease with $n$. The $v_2$ and $v_3$ values are found to be positive in the measured $p_{\rm T}$ range. The $v_1$ is also measured as a function of $p_{\rm T}$ and is observed to change sign around $p_{\rm T}\approx 1.5$-2.0 GeV and then increase to about 0.1 for $p_{\rm T}>4$ GeV. The $v_2(p_{\rm T})$, $v_3(p_{\rm T})$ and $v_4(p_{\rm T})$ are compared to the $v_n$ coefficients in Pb+Pb collisions at $\sqrt{s_{\mathrm{NN}}} =2.76$ TeV with similar event multiplicities. Reasonable agreement is observed after accounting for the difference in the average $p_{\rm T}$ of particles produced in the two collision systems.
The distributions of $N_{ch}^{rec}$ for MB and MB+HMT after applying an event-by-event weight, errors are statistical.
The distributions of $E_{T}^{Pb}$ [GeV] for MB and MB+HMT after applying an event-by-event weight, errors are statistical.
$v_{2,2}^{unsub}$ and $v_{2,2}$ as a function of $\Delta\eta$ calculated from the 2-D per-trigger yields in figure 4(a) and 4(b), respectively.
$v_{3,3}^{unsub}$ and $v_{3,3}$ as a function of $\Delta\eta$ calculated from the 2-D per-trigger yields in figure 4(a) and 4(b), respectively.
$v_{4,4}^{unsub}$ and $v_{4,4}$ as a function of $\Delta\eta$ calculated from the 2-D per-trigger yields in figure 4(a) and 4(b), respectively.
Integrated per-trigger yield, $Y_{int}$, on the near-side as a function of $p_{T}^{a}$ for 1 $< p_{T}^{b} <$ 3 GeV.
Integrated per-trigger yield, $Y_{int}$, on the near-side as a function of $p_{T}^{a}$ for 1 $< p_{T}^{b} <$ 3 GeV.
Integrated per-trigger yield, $Y_{int}$, on the near-side as a function of $p_{T}^{a}$ for 1 $< p_{T}^{b} <$ 3 GeV.
Integrated per-trigger yield, $Y_{int}$, on the near-side as a function of $p_{T}^{a}$ for 1 $< p_{T}^{b} <$ 3 GeV.
Integrated per-trigger yield, $Y_{int}$, on the near-side as a function of $p_{T}^{a}$ for 1 $< p_{T}^{b} <$ 3 GeV.
Integrated per-trigger yield, $Y_{int}$, on the away-side as a function of $p_{T}^{a}$ for 1 $< p_{T}^{b} <$ 3 GeV.
Integrated per-trigger yield, $Y_{int}$, on the away-side as a function of $p_{T}^{a}$ for 1 $< p_{T}^{b} <$ 3 GeV.
Integrated per-trigger yield, $Y_{int}$, on the away-side as a function of $p_{T}^{a}$ for 1 $< p_{T}^{b} <$ 3 GeV.
Integrated per-trigger yield, $Y_{int}$, on the away-side as a function of $p_{T}^{a}$ for 1 $< p_{T}^{b} <$ 3 GeV.
Integrated per-trigger yield, $Y_{int}$, on the away-side as a function of $p_{T}^{a}$ for 1 $< p_{T}^{b} <$ 3 GeV.
The Fourier coefficients $v_{n}$ as a function of $p_{T}^{a}$ extracted from the correlation functions, before and after the subtraction of the recoil component.
The Fourier coefficients $v_{n}$ as a function of $p_{T}^{a}$ extracted from the correlation functions, before and after the subtraction of the recoil component.
The Fourier coefficients $v_{n}$ as a function of $p_{T}^{a}$ extracted from the correlation functions, before and after the subtraction of the recoil component.
$v_{2}$, $v_{3}$, $v_{4}$ and $v_{5}$ as a function of $p_T^a$ for 1 $< p_{T}^{b} <$ 3 GeV for different $N_{ch}^{rec}$ intervals.
$v_{2}$, $v_{3}$, $v_{4}$ and $v_{5}$ as a function of $p_T^a$ for 1 $< p_{T}^{b} <$ 3 GeV for different $N_{ch}^{rec}$ intervals.
$v_{2}$, $v_{3}$, $v_{4}$ and $v_{5}$ as a function of $p_T^a$ for 1 $< p_{T}^{b} <$ 3 GeV for different $N_{ch}^{rec}$ intervals.
$v_{2}$, $v_{3}$, $v_{4}$ and $v_{5}$ as a function of $p_T^a$ for 1 $< p_{T}^{b} <$ 3 GeV for different $N_{ch}^{rec}$ intervals.
$v_{2}$, $v_{3}$, $v_{4}$ and $v_{5}$ as a function of $p_T^a$ for 1 $< p_{T}^{b} <$ 3 GeV for different $N_{ch}^{rec}$ intervals.
$v_{2}$, $v_{3}$, $v_{4}$ and $v_{5}$ as a function of $p_T^a$ for 1 $< p_{T}^{b} <$ 3 GeV for different $N_{ch}^{rec}$ intervals.
The centrality dependence of $v_{2}$ as a function of $N_{ch}^{rec}$. Values from before and after the recoil subtraction are included.
The centrality dependence of $v_{3}$ as a function of $N_{ch}^{rec}$. Values from before and after the recoil subtraction are included.
The centrality dependence of $v_{4}$ as a function of $N_{ch}^{rec}$. Values from before and after the recoil subtraction are included.
The centrality dependence of $v_{2}$ as a function of $E_{T}^{Pb}$. Values from before and after the recoil subtraction are included.
The centrality dependence of $v_{3}$ as a function of $E_{T}^{Pb}$. Values from before and after the recoil subtraction are included.
The centrality dependence of $v_{4}$ as a function of $E_{T}^{Pb}$. Values from before and after the recoil subtraction are included.
The $v_{2}$ as a function of $E_{T}^{Pb}$ obtained indirectly by mapping from the $N_{ch}^{rec}-dependence of $v_{2}$ using the correlation data shown in Fig. 2(b).
The $v_{3}$ as a function of $E_{T}^{Pb}$ obtained indirectly by mapping from the $N_{ch}^{rec}-dependence of $v_{3}$ using the correlation data shown in Fig. 2(b).
The first-order harmonic of 2PC before recoil subtraction, $v_{1,1}^{unsub}$, as a function of $p_T^a$ for different $p_T^b$ ranges for events with $N_{ch}^{rec} \geq$ 220.
The first-order harmonic of 2PC before recoil subtraction, $v_{1,1}^{unsub}$, as a function of $p_T^a$ for different $p_T^b$ ranges for events with $N_{ch}^{rec} \geq$ 220.
The first-order harmonic of 2PC before recoil subtraction, $v_{1,1}^{unsub}$, as a function of $p_T^a$ for different $p_T^b$ ranges for events with $N_{ch}^{rec} \geq$ 220.
The first-order harmonic of 2PC before recoil subtraction, $v_{1,1}^{unsub}$, as a function of $p_T^a$ for different $p_T^b$ ranges for events with $N_{ch}^{rec} \geq$ 220.
The first-order harmonic of 2PC before recoil subtraction, $v_{1,1}^{unsub}$, as a function of $p_T^a$ for different $p_T^b$ ranges for events with $N_{ch}^{rec} \geq$ 220.
The first-order harmonic of 2PC before recoil subtraction, $v_{1,1}^{unsub}$, as a function of $p_T^a$ for different $p_T^b$ ranges for events with $N_{ch}^{rec} \geq$ 220.
The first-order harmonic of 2PC after recoil subtraction, $v_{1,1}$, as a function of $p_T^a$ for different $p_T^b$ ranges for events with $N_{ch}^{rec} \geq$ 220.
The first-order harmonic of 2PC after recoil subtraction, $v_{1,1}$, as a function of $p_T^a$ for different $p_T^b$ ranges for events with $N_{ch}^{rec} \geq$ 220.
The first-order harmonic of 2PC after recoil subtraction, $v_{1,1}$, as a function of $p_T^a$ for different $p_T^b$ ranges for events with $N_{ch}^{rec} \geq$ 220.
The first-order harmonic of 2PC after recoil subtraction, $v_{1,1}$, as a function of $p_T^a$ for different $p_T^b$ ranges for events with $N_{ch}^{rec} \geq$ 220.
The first-order harmonic of 2PC after recoil subtraction, $v_{1,1}$, as a function of $p_T^a$ for different $p_T^b$ ranges for events with $N_{ch}^{rec} \geq$ 220.
The first-order harmonic of 2PC after recoil subtraction, $v_{1,1}$, as a function of $p_T^a$ for different $p_T^b$ ranges for events with $N_{ch}^{rec} \geq$ 220.
The first-order harmonic $v_1$ obtained using factorization from $v_{1,1}$, as a function of $p_T^a$ for different $p_T^b$ ranges for events with $N_{ch}^{rec} \geq$ 220.
The first-order harmonic $v_1$ obtained using factorization from $v_{1,1}$, as a function of $p_T^a$ for different $p_T^b$ ranges for events with $N_{ch}^{rec} \geq$ 220.
The first-order harmonic $v_1$ obtained using factorization from $v_{1,1}$, as a function of $p_T^a$ for different $p_T^b$ ranges for events with $N_{ch}^{rec} \geq$ 220.
$v_{2}$ for Pb+Pb collisions in 55-60% centrality interval obtained using an EP method.
$v_{2}$ for Pb+Pb collisions in 55-60% centrality interval obtained using an EP method, after the scaling.
$v_{3}$ for Pb+Pb collisions in 55-60% centrality interval obtained using an EP method.
$v_{3}$ for Pb+Pb collisions in 55-60% centrality interval obtained using an EP method, after the scaling.
$v_{4}$ for Pb+Pb collisions in 55-60% centrality interval obtained using an EP method.
$v_{4}$ for Pb+Pb collisions in 55-60% centrality interval obtained using an EP method, after the scaling.
Correlation between $E_{T}^{FCal}$ and $N_{ch}^{rec}$ for MB events (without weighting) and MB+HMT events (with weighting), errors are statistical.
When you search on a word, e.g. 'collisions', we will automatically search across everything we store about a record. But sometimes you may wish to be more specific. Here we show you how.
Guidance on the query string syntax can also be found in the OpenSearch documentation.
About HEPData Submitting to HEPData HEPData File Formats HEPData Coordinators HEPData Terms of Use HEPData Cookie Policy
Status Email Forum Twitter GitHub
Copyright ~1975-Present, HEPData | Powered by Invenio, funded by STFC, hosted and originally developed at CERN, supported and further developed at IPPP Durham.