Showing 7 of 7 results
Measurements of the azimuthal anisotropy in lead-lead collisions at $\sqrt{s_\mathrm{NN}} = 5.02$ TeV are presented using a data sample corresponding to 0.49 $\mathrm{nb}^{-1}$ integrated luminosity collected by the ATLAS experiment at the LHC in 2015. The recorded minimum-bias sample is enhanced by triggers for "ultra-central" collisions, providing an opportunity to perform detailed study of flow harmonics in the regime where the initial state is dominated by fluctuations. The anisotropy of the charged-particle azimuthal angle distributions is characterized by the Fourier coefficients, $v_{2}-v_{7}$, which are measured using the two-particle correlation, scalar-product and event-plane methods. The goal of the paper is to provide measurements of the differential as well as integrated flow harmonics $v_{n}$ over wide ranges of the transverse momentum, 0.5 $
The V2 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-0.1%
The V2 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-1%
The V2 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-5%
The V2 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 5-10%
The V2 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 10-20%
The V2 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 20-30%
The V2 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 30-40%
The V2 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 40-50%
The V2 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 50-60%
The V2 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 60-70%
The V2 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 70-80%
The V3 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-0.1%
The V3 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-1%
The V3 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-5%
The V3 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 5-10%
The V3 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 10-20%
The V3 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 20-30%
The V3 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 30-40%
The V3 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 40-50%
The V3 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 50-60%
The V3 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 60-70%
The V3 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 70-80%
The V4 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-0.1%
The V4 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-1%
The V4 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-5%
The V4 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 5-10%
The V4 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 10-20%
The V4 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 20-30%
The V4 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 30-40%
The V4 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 40-50%
The V4 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 50-60%
The V4 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 60-70%
The V4 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 70-80%
The V5 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-0.1%
The V5 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-1%
The V5 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-5%
The V5 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 5-10%
The V5 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 10-20%
The V5 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 20-30%
The V5 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 30-40%
The V5 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 40-50%
The V5 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 50-60%
The V5 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 60-70%
The V5 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 70-80%
The V6 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-5%
The V6 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 5-10%
The V6 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 10-20%
The V6 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 20-30%
The V6 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 30-40%
The V6 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 40-50%
The V6 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 50-60%
The V6 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 60-70%
The V6 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 70-80%
The V7 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-5%
The V7 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 5-10%
The V7 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 10-20%
The V7 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 20-30%
The V7 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 30-40%
The V7 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 40-50%
The V7 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 50-60%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 0-5%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 5-10%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 10-20%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 20-30%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 30-40%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 40-50%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 50-60%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 60-70%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 70-80%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 0-5%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 5-10%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 10-20%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 20-30%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 30-40%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 40-50%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 50-60%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 60-70%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 70-80%
The V4 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 0-5%
The V4 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 5-10%
The V4 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 10-20%
The V4 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 20-30%
The V4 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 30-40%
The V4 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 40-50%
The V4 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 50-60%
The V4 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 60-70%
The V4 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 70-80%
The V5 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 0-5%
The V5 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 5-10%
The V5 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 10-20%
The V5 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 20-30%
The V5 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 30-40%
The V5 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 40-50%
The V5 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 50-60%
The V5 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 60-70%
The V6 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 0-5%
The V6 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 5-10%
The V6 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 10-20%
The V6 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 20-30%
The V6 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 30-40%
The V6 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 40-50%
The V6 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 50-60%
The V6 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 60-70%
The ratio of V2{SP} over V2{EP} as a funtion of transverse momentum in centrality bin 0-5%
The ratio of V2{SP} over V2{EP} as a funtion of transverse momentum in centrality bin 20-30%
The ratio of V2{SP} over V2{EP} as a funtion of transverse momentum in centrality bin 40-50%
The ratio of V3{SP} over V3{EP} as a funtion of transverse momentum in centrality bin 0-5%
The ratio of V3{SP} over V3{EP} as a funtion of transverse momentum in centrality bin 20-30%
The ratio of V3{SP} over V3{EP} as a funtion of transverse momentum in centrality bin 40-50%
The ratio of V4{SP} over V4{EP} as a funtion of transverse momentum in centrality bin 0-5%
The ratio of V4{SP} over V4{EP} as a funtion of transverse momentum in centrality bin 20-30%
The ratio of V4{SP} over V4{EP} as a funtion of transverse momentum in centrality bin 40-50%
The ratio of V5{SP} over V5{EP} as a funtion of transverse momentum in centrality bin 0-5%
The ratio of V5{SP} over V5{EP} as a funtion of transverse momentum in centrality bin 20-30%
The ratio of V5{SP} over V5{EP} as a funtion of transverse momentum in centrality bin 40-50%
The ratio of V6{SP} over V6{EP} as a funtion of transverse momentum in centrality bin 0-5%
The ratio of V6{SP} over V6{EP} as a funtion of transverse momentum in centrality bin 20-30%
The ratio of V6{SP} over V6{EP} as a funtion of transverse momentum in centrality bin 40-50%
The ratio of V2{SP} over V2{EP} as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The ratio of V3{SP} over V3{EP} as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The ratio of V4{SP} over V4{EP} as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The ratio of V5{SP} over V5{EP} as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The ratio of V6{SP} over V6{EP} as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The ratio of V2{SP} over V2{2PC} as a funtion of transverse momentum in centrality bin 0-5%
The ratio of V2{SP} over V2{2PC} as a funtion of transverse momentum in centrality bin 20-30%
The ratio of V2{SP} over V2{2PC} as a funtion of transverse momentum in centrality bin 40-50%
The ratio of V3{SP} over V3{2PC} as a funtion of transverse momentum in centrality bin 0-5%
The ratio of V3{SP} over V3{2PC} as a funtion of transverse momentum in centrality bin 20-30%
The ratio of V3{SP} over V3{2PC} as a funtion of transverse momentum in centrality bin 40-50%
The ratio of V4{SP} over V4{2PC} as a funtion of transverse momentum in centrality bin 0-5%
The ratio of V4{SP} over V4{2PC} as a funtion of transverse momentum in centrality bin 20-30%
The ratio of V4{SP} over V4{2PC} as a funtion of transverse momentum in centrality bin 40-50%
The ratio of V5{SP} over V5{2PC} as a funtion of transverse momentum in centrality bin 0-5%
The ratio of V5{SP} over V5{2PC} as a funtion of transverse momentum in centrality bin 20-30%
The ratio of V5{SP} over V5{2PC} as a funtion of transverse momentum in centrality bin 40-50%
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-5%. PT binning matched to RUN1.
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 20-30%. PT binning matched to RUN1.
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 40-50%. PT binning matched to RUN1.
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-5%. PT binning matched to RUN1.
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 20-30%. PT binning matched to RUN1.
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 40-50%. PT binning matched to RUN1.
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-5%. PT binning matched to RUN1.
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 20-30%. PT binning matched to RUN1.
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 40-50%. PT binning matched to RUN1.
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-5%. PT binning matched to RUN1.
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 20-30%. PT binning matched to RUN1.
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 40-50%. PT binning matched to RUN1.
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-5%. PT binning matched to RUN1.
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 20-30%. PT binning matched to RUN1.
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 40-50%. PT binning matched to RUN1.
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-0.1%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-5%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 10-20%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 30-40%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 60-70%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-0.1%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-5%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 10-20%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 30-40%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 60-70%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-0.1%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-5%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 10-20%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 30-40%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 60-70%
The V5 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-0.1%
The V5 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-5%
The V5 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 10-20%
The V5 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 30-40%
The V5 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 60-70%
The V6 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-5%
The V6 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 10-20%
The V6 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 30-40%
The V6 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 60-70%
The V7 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-5%
The V7 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 10-20%
The V7 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 30-40%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-0.1%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-5%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 10-20%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 30-40%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 60-70%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-0.1%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-5%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 10-20%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 30-40%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 60-70%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-0.1%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-5%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 10-20%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 30-40%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 60-70%
The V5 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-0.1%
The V5 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-5%
The V5 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 10-20%
The V5 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 30-40%
The V5 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 60-70%
The V6 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-5%
The V6 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 10-20%
The V6 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 30-40%
The V6 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 60-70%
The V7 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-5%
The V7 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 10-20%
The V7 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 30-40%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 0-0.1%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 0-5%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 10-20%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 30-40%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 60-70%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 0-0.1%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 0-5%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 10-20%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 30-40%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 0-0.1%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 0-5%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 10-20%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 30-40%
The V2 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 0.8 GeV
The V2 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.8 < PT < 1 GeV
The V2 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 1 < PT < 2 GeV
The V2 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 2 < PT < 4 GeV
The V2 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 4 < PT < 8 GeV
The V2 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 8 < PT < 60 GeV
The V2 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The V3 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 0.8 GeV
The V3 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.8 < PT < 1 GeV
The V3 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 1 < PT < 2 GeV
The V3 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 2 < PT < 4 GeV
The V3 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 4 < PT < 8 GeV
The V3 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 8 < PT < 60 GeV
The V3 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The V4 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 0.8 GeV
The V4 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.8 < PT < 1 GeV
The V4 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 1 < PT < 2 GeV
The V4 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 2 < PT < 4 GeV
The V4 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 4 < PT < 8 GeV
The V4 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 8 < PT < 60 GeV
The V4 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The V5 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 0.8 GeV
The V5 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.8 < PT < 1 GeV
The V5 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 1 < PT < 2 GeV
The V5 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 2 < PT < 4 GeV
The V5 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 4 < PT < 8 GeV
The V5 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 8 < PT < 60 GeV
The V5 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The V6 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 0.8 GeV
The V6 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.8 < PT < 1 GeV
The V6 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 1 < PT < 2 GeV
The V6 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 2 < PT < 4 GeV
The V6 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 4 < PT < 8 GeV
The V6 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 8 < PT < 60 GeV
The V6 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The V7 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 0.8 GeV
The V7 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.8 < PT < 1 GeV
The V7 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 1 < PT < 2 GeV
The V7 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 2 < PT < 4 GeV
The V7 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 4 < PT < 8 GeV
The V7 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 8 < PT < 60 GeV
The V7 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 0-5%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 10-15%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 20-25%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 30-35%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 40-45%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 50-55%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 0-5%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 10-15%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 20-25%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 30-35%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 40-45%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 50-55%
The scaled-V2(PT) measured with the two particle correlation method in centrality bin 0-5%
The scaled-V2(PT) measured with the two particle correlation method in centrality bin 10-15%
The scaled-V2(PT) measured with the two particle correlation method in centrality bin 20-25%
The scaled-V2(PT) measured with the two particle correlation method in centrality bin 30-35%
The scaled-V2(PT) measured with the two particle correlation method in centrality bin 40-45%
The scaled-V2(PT) measured with the two particle correlation method in centrality bin 50-55%
The scaled-V3(PT) measured with the two particle correlation method in centrality bin 0-5%
The scaled-V3(PT) measured with the two particle correlation method in centrality bin 10-15%
The scaled-V3(PT) measured with the two particle correlation method in centrality bin 20-25%
The scaled-V3(PT) measured with the two particle correlation method in centrality bin 30-35%
The scaled-V3(PT) measured with the two particle correlation method in centrality bin 40-45%
The scaled-V3(PT) measured with the two particle correlation method in centrality bin 50-55%
The PT scale factor for V2(PT) as a funtion of collision centrality
The PT scale factor for V3(PT) as a funtion of collision centrality
The V2 scale factor as a funtion of collision centrality
The V3 scale factor as a funtion of collision centrality
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-0.1%
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-1%
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-5%
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 5-10%
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 10-20%
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 20-30%
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 30-40%
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 40-50%
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 50-60%
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 60-70%
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 70-80%
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-0.1%
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-1%
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-5%
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 5-10%
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 10-20%
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 20-30%
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 30-40%
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 40-50%
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 50-60%
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 60-70%
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 70-80%
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-0.1%
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-1%
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-5%
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 5-10%
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 10-20%
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 20-30%
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 30-40%
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 40-50%
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 50-60%
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 60-70%
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 70-80%
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-0.1%
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-1%
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-5%
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 5-10%
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 10-20%
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 20-30%
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 30-40%
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 40-50%
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 50-60%
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 60-70%
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 70-80%
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-5%
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 5-10%
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 10-20%
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 20-30%
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 30-40%
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 40-50%
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 50-60%
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 60-70%
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 70-80%
The V7 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-5%
The V7 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 5-10%
The V7 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 10-20%
The V7 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 20-30%
The V7 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 30-40%
The V7 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 40-50%
The V7 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 50-60%
The V2 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-0.1%
The V2 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-5%
The V2 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 10-20%
The V2 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 30-40%
The V2 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 60-70%
The V3 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-0.1%
The V3 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-5%
The V3 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 10-20%
The V3 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 30-40%
The V3 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 60-70%
The V4 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-0.1%
The V4 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-5%
The V4 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 10-20%
The V4 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 30-40%
The V4 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 60-70%
The V5 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-0.1%
The V5 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-5%
The V5 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 10-20%
The V5 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 30-40%
The V5 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 60-70%
The V6 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-5%
The V6 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 10-20%
The V6 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 30-40%
The V6 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 60-70%
The V7 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-5%
The V7 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 10-20%
The V7 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 30-40%
The V2 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-0.1%
The V2 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-5%
The V2 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 10-20%
The V2 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 30-40%
The V2 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 60-70%
The V3 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-0.1%
The V3 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-5%
The V3 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 10-20%
The V3 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 30-40%
The V3 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 60-70%
The V4 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-0.1%
The V4 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-5%
The V4 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 10-20%
The V4 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 30-40%
The V4 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 60-70%
The V5 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-0.1%
The V5 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-5%
The V5 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 10-20%
The V5 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 30-40%
The V5 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 60-70%
The V6 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-5%
The V6 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 10-20%
The V6 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 30-40%
The V6 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 60-70%
The V7 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-5%
The V7 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 10-20%
The V7 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 30-40%
The V2 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 0-0.1%
The V2 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 0-5%
The V2 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 10-20%
The V2 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 30-40%
The V2 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 60-70%
The V3 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 0-0.1%
The V3 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 0-5%
The V3 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 10-20%
The V3 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 30-40%
The V4 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 0-0.1%
The V4 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 0-5%
The V4 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 10-20%
The V4 harmonic measured with the event plane method as a function of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 30-40%
The V2 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 0.8 GeV
The V2 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.8 < PT < 1 GeV
The V2 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 1 < PT < 2 GeV
The V2 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 2 < PT < 4 GeV
The V2 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 4 < PT < 8 GeV
The V2 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 8 < PT < 60 GeV
The V2 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The V3 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 0.8 GeV
The V3 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.8 < PT < 1 GeV
The V3 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 1 < PT < 2 GeV
The V3 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 2 < PT < 4 GeV
The V3 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 4 < PT < 8 GeV
The V3 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 8 < PT < 60 GeV
The V3 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The V4 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 0.8 GeV
The V4 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.8 < PT < 1 GeV
The V4 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 1 < PT < 2 GeV
The V4 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 2 < PT < 4 GeV
The V4 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 4 < PT < 8 GeV
The V4 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 8 < PT < 60 GeV
The V4 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The V5 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 0.8 GeV
The V5 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.8 < PT < 1 GeV
The V5 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 1 < PT < 2 GeV
The V5 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 2 < PT < 4 GeV
The V5 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 4 < PT < 8 GeV
The V5 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 8 < PT < 60 GeV
The V5 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The V6 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 0.8 GeV
The V6 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.8 < PT < 1 GeV
The V6 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 1 < PT < 2 GeV
The V6 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 2 < PT < 4 GeV
The V6 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 4 < PT < 8 GeV
The V6 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 8 < PT < 60 GeV
The V6 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The V7 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 0.8 GeV
The V7 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.8 < PT < 1 GeV
The V7 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 1 < PT < 2 GeV
The V7 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 2 < PT < 4 GeV
The V7 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 4 < PT < 8 GeV
The V7 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 8 < PT < 60 GeV
The V7 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
We present the first measurement of the two-particle transverse momentum differential correlation function, $P_2\equiv\langle \Delta p_{\rm T} \Delta p_{\rm T} \rangle /\langle p_{\rm T} \rangle^2$, in Pb-Pb collisions at $\sqrt{s_{_{\rm NN}}} =$ 2.76 TeV. Results for $P_2$ are reported as a function of relative pseudorapidity ($\Delta \eta$) and azimuthal angle ($\Delta \varphi$) between two particles for different collision centralities. The $\Delta \phi$ dependence is found to be largely independent of $\Delta \eta$ for $|\Delta \eta| \geq$ 0.9. In 5% most central Pb-Pb collisions, the two-particle transverse momentum correlation function exhibits a clear double-hump structure around $\Delta \varphi = \pi$ (i.e., on the away side), which is not observed in number correlations in the same centrality range, and thus provides an indication of the dominance of triangular flow in this collision centrality. Fourier decompositions of $P_2$, studied as a function of collision centrality, show that correlations at $|\Delta \eta| \geq$ 0.9 can be well reproduced by a flow ansatz based on the notion that measured momentum correlations are strictly determined by the collective motion of the system.
Projection of $P_{2}$ along $\Delta\varphi$ in 0-5% centrality in the range $|\Delta \eta| \geq$ 0.9
$v_{2}$ coefficients measured from $P_2$ for particle pairs in the range $0.2 \leq |\Delta\eta| \leq 0.9$.
$v_{2}$ coefficients measured from $P_2$ for particle pairs in the range $0.9 \leq |\Delta\eta| \leq 1.9$.
$v_{2}$ coefficients estimated from the flow ansatz in the range $0.2 \leq |\Delta\eta| \leq 0.9$.
$v_{2}$ coefficients estimated from the flow ansatz in the range $0.9 \leq |\Delta\eta| \leq 1.9$.
$v_{3}$ coefficients measured from $P_2$ for particle pairs in the range $0.2 \leq |\Delta\eta| \leq 0.9$.
$v_{3}$ coefficients measured from $P_2$ for particle pairs in the range $0.9 \leq |\Delta\eta| \leq 1.9$.
$v_{3}$ coefficients estimatEd from the flow ansatz in the range $0.2 \leq |\Delta\eta| \leq 0.9$.
$v_{3}$ coefficients estimatEd from the flow ansatz in the range $0.9 \leq |\Delta\eta| \leq 1.9$.
$v_{4}$ coefficients measured from $P_2$ for particle pairs in the range $0.2 \leq |\Delta\eta| \leq 0.9$.
$v_{4}$ coefficients measured from $P_2$ for particle pairs in the range $0.9 \leq |\Delta\eta| \leq 1.9$.
$v_{4}$ coefficients estimatEd from the flow ansatz in the range $0.2 \leq |\Delta\eta| \leq 0.9$.
$v_{4}$ coefficients estimatEd from the flow ansatz in the range $0.9 \leq |\Delta\eta| \leq 1.9$.
$v_{2}[P_2]$ coefficients vs pair separation in pseudorapidity in 0-5% centrality.
$v_{2}[R_2]$ coefficients vs pair separation in pseudorapidity in 0-5% centrality.
$v_{3}[P_2]$ coefficients vs pair separation in pseudorapidity in 0-5% centrality.
$v_{3}[R_2]$ coefficients vs pair separation in pseudorapidity in 0-5% centrality.
$v_{4}[P_2]$ coefficients vs pair separation in pseudorapidity in 0-5% centrality.
$v_{4}[R_2]$ coefficients vs pair separation in pseudorapidity in 0-5% centrality.
We present measurements of the elliptic ($\mathrm{v}_2$), triangular ($\mathrm{v}_3$) and quadrangular ($\mathrm{v}_4$) anisotropic azimuthal flow over a wide range of pseudorapidities ($-3.5< \eta < 5$). The measurements are performed with Pb-Pb collisions at $\sqrt{s_{\text{NN}}} = 2.76$ TeV using the ALICE detector at the Large Hadron Collider (LHC). The flow harmonics are obtained using two- and four-particle correlations from nine different centrality intervals covering central to peripheral collisions. We find that the shape of $\mathrm{v}_n(\eta)$ is largely independent of centrality for the flow harmonics $n=2-4$, however the higher harmonics fall off more steeply with increasing $|\eta|$. We assess the validity of extended longitudinal scaling of $\mathrm{v}_2$ by comparing to lower energy measurements, and find that the higher harmonic flow coefficients are proportional to the charged particle densities at larger pseudorapidities. Finally, we compare our measurements to both hydrodynamical and transport models, and find they both have challenges when it comes to describing our data.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
We report the first results of elliptic ($v_2$), triangular ($v_3$) and quadrangular flow ($v_4$) of charged particles in Pb-Pb collisions at $\sqrt{s_{\rm NN}}=5.02$ TeV with the ALICE detector at the CERN Large Hadron Collider. The measurements are performed in the central pseudorapidity region $|\eta|<0.8$ and for the transverse momentum range $0.2
Centrality dependence of $v_2$, with two- and multi-particle correlations, integrated over the $p_{\rm T}$ range 0.2 < $p_{\rm T}$ < 5.0 GeV/$c$, at $\sqrt{s_{\rm NN}}$ = 5.02 TeV.
Centrality dependence of $v_3$ and $v_4$, with two-particle correlations, integrated over the $p_{\rm T}$ range 0.2 < $p_{\rm T}$ < 5.0 GeV/c, at $\sqrt{s_{\rm NN}}$ = 5.02 TeV.
Centrality dependence of $v_2$, with two- and multi-particle correlations, integrated over the $p_{\rm T}$ range 0.2 < $p_{\rm T}$ < 5.0 GeV/c, at $\sqrt{s_{\rm NN}}$ = 2.76 TeV.
Centrality dependence of $v_3$ and $v_4$, with two-particle correlations, integrated over the $p_{\rm T}$ range 0.2 < $p_{\rm T}$ < 5.0 GeV/c, at $\sqrt{s_{\rm NN}}$ = 2.76 TeV.
Ratio of $p_{\rm T}$-integrated $v_2$ between $\sqrt{s_{\rm NN}}$ = 5.02 and 2.76 TeV.
Ratio of $p_{\rm T}$-integrated $v_3$ and $v_4$ between $\sqrt{s_{\rm NN}}$ = 5.02 and 2.76 TeV.
$p_{\rm T}$ dependence of $v_2$, $v_3$ and $v_4$ for centrality 0-5%.
$p_{\rm T}$ dependence of $v_2$, $v_3$ and $v_4$ for centrality 30-40%.
$p_{\rm T}$ dependence of $v_2${4} for centralities 10-20%, 20-30% and 30-40%.
Ratio of $p_{\rm T}$-differential $v_2${4} between $\sqrt{s_{\rm NN}}$ = 5.02 and 2.76 TeV, for centrality 20-30%.
Fully $p_{\rm T}$-integrated $v_2${4} at $\sqrt{s_{\rm NN}}$ = 2.76 and 5.02 TeV, for centrality 20-30%.
Correlations between the elliptic or triangular flow coefficients $v_m$ ($m$=2 or 3) and other flow harmonics $v_n$ ($n$=2 to 5) are measured using $\sqrt{s_{NN}}=2.76$ TeV Pb+Pb collision data collected in 2010 by the ATLAS experiment at the LHC, corresponding to an integrated lumonisity of 7 $\mu$b$^{-1}$. The $v_m$-$v_n$ correlations are measured in midrapidity as a function of centrality, and, for events within the same centrality interval, as a function of event ellipticity or triangularity defined in a forward rapidity region. For events within the same centrality interval, $v_3$ is found to be anticorrelated with $v_2$ and this anticorrelation is consistent with similar anticorrelations between the corresponding eccentricities $\epsilon_2$ and $\epsilon_3$. On the other hand, it is observed that $v_4$ increases strongly with $v_2$, and $v_5$ increases strongly with both $v_2$ and $v_3$. The trend and strength of the $v_m$-$v_n$ correlations for $n$=4 and 5 are found to disagree with $\epsilon_m$-$\epsilon_n$ correlations predicted by initial-geometry models. Instead, these correlations are found to be consistent with the combined effects of a linear contribution to $v_n$ and a nonlinear term that is a function of $v_2^2$ or of $v_2v_3$, as predicted by hydrodynamic models. A simple two-component fit is used to separate these two contributions. The extracted linear and nonlinear contributions to $v_4$ and $v_5$ are found to be consistent with previously measured event-plane correlations.
$v_{2}$ data for various $q_2$ bins, Centrality 0-5%.
$v_{3}$ data for various $q_2$ bins, Centrality 0-5%.
$v_{4}$ data for various $q_2$ bins, Centrality 0-5%.
$v_{5}$ data for various $q_2$ bins, Centrality 0-5%.
$v_{2}$ data for various $q_2$ bins, Centrality 5-10%.
$v_{3}$ data for various $q_2$ bins, Centrality 5-10%.
$v_{4}$ data for various $q_2$ bins, Centrality 5-10%.
$v_{5}$ data for various $q_2$ bins, Centrality 5-10%.
$v_{2}$ data for various $q_2$ bins, Centrality 10-15%.
$v_{3}$ data for various $q_2$ bins, Centrality 10-15%.
$v_{4}$ data for various $q_2$ bins, Centrality 10-15%.
$v_{5}$ data for various $q_2$ bins, Centrality 10-15%.
$v_{2}$ data for various $q_2$ bins, Centrality 15-20%.
$v_{3}$ data for various $q_2$ bins, Centrality 15-20%.
$v_{4}$ data for various $q_2$ bins, Centrality 15-20%.
$v_{5}$ data for various $q_2$ bins, Centrality 15-20%.
$v_{2}$ data for various $q_2$ bins, Centrality 20-25%.
$v_{3}$ data for various $q_2$ bins, Centrality 20-25%.
$v_{4}$ data for various $q_2$ bins, Centrality 20-25%.
$v_{5}$ data for various $q_2$ bins, Centrality 20-25%.
$v_{2}$ data for various $q_2$ bins, Centrality 25-30%.
$v_{3}$ data for various $q_2$ bins, Centrality 25-30%.
$v_{4}$ data for various $q_2$ bins, Centrality 25-30%.
$v_{5}$ data for various $q_2$ bins, Centrality 25-30%.
$v_{2}$ data for various $q_2$ bins, Centrality 30-35%.
$v_{3}$ data for various $q_2$ bins, Centrality 30-35%.
$v_{4}$ data for various $q_2$ bins, Centrality 30-35%.
$v_{5}$ data for various $q_2$ bins, Centrality 30-35%.
$v_{2}$ data for various $q_2$ bins, Centrality 35-40%.
$v_{3}$ data for various $q_2$ bins, Centrality 35-40%.
$v_{4}$ data for various $q_2$ bins, Centrality 35-40%.
$v_{5}$ data for various $q_2$ bins, Centrality 35-40%.
$v_{2}$ data for various $q_2$ bins, Centrality 40-45%.
$v_{3}$ data for various $q_2$ bins, Centrality 40-45%.
$v_{4}$ data for various $q_2$ bins, Centrality 40-45%.
$v_{5}$ data for various $q_2$ bins, Centrality 40-45%.
$v_{2}$ data for various $q_2$ bins, Centrality 45-50%.
$v_{3}$ data for various $q_2$ bins, Centrality 45-50%.
$v_{4}$ data for various $q_2$ bins, Centrality 45-50%.
$v_{5}$ data for various $q_2$ bins, Centrality 45-50%.
$v_{2}$ data for various $q_2$ bins, Centrality 50-55%.
$v_{3}$ data for various $q_2$ bins, Centrality 50-55%.
$v_{4}$ data for various $q_2$ bins, Centrality 50-55%.
$v_{5}$ data for various $q_2$ bins, Centrality 50-55%.
$v_{2}$ data for various $q_2$ bins, Centrality 55-60%.
$v_{3}$ data for various $q_2$ bins, Centrality 55-60%.
$v_{4}$ data for various $q_2$ bins, Centrality 55-60%.
$v_{5}$ data for various $q_2$ bins, Centrality 55-60%.
$v_{2}$ data for various $q_2$ bins, Centrality 60-65%.
$v_{3}$ data for various $q_2$ bins, Centrality 60-65%.
$v_{4}$ data for various $q_2$ bins, Centrality 60-65%.
$v_{5}$ data for various $q_2$ bins, Centrality 60-65%.
$v_{2}$ data for various $q_2$ bins, Centrality 65-70%.
$v_{3}$ data for various $q_2$ bins, Centrality 65-70%.
$v_{4}$ data for various $q_2$ bins, Centrality 65-70%.
$v_{5}$ data for various $q_2$ bins, Centrality 65-70%.
$v_{2}$ data for various $q_2$ bins, Centrality 0-10%.
$v_{3}$ data for various $q_2$ bins, Centrality 0-10%.
$v_{4}$ data for various $q_2$ bins, Centrality 0-10%.
$v_{5}$ data for various $q_2$ bins, Centrality 0-10%.
$v_{2}$ data for various $q_2$ bins, Centrality 10-20%.
$v_{3}$ data for various $q_2$ bins, Centrality 10-20%.
$v_{4}$ data for various $q_2$ bins, Centrality 10-20%.
$v_{5}$ data for various $q_2$ bins, Centrality 10-20%.
$v_{2}$ data for various $q_2$ bins, Centrality 20-30%.
$v_{3}$ data for various $q_2$ bins, Centrality 20-30%.
$v_{4}$ data for various $q_2$ bins, Centrality 20-30%.
$v_{5}$ data for various $q_2$ bins, Centrality 20-30%.
$v_{2}$ data for various $q_2$ bins, Centrality 30-40%.
$v_{3}$ data for various $q_2$ bins, Centrality 30-40%.
$v_{4}$ data for various $q_2$ bins, Centrality 30-40%.
$v_{5}$ data for various $q_2$ bins, Centrality 30-40%.
$v_{2}$ data for various $q_2$ bins, Centrality 40-50%.
$v_{3}$ data for various $q_2$ bins, Centrality 40-50%.
$v_{4}$ data for various $q_2$ bins, Centrality 40-50%.
$v_{5}$ data for various $q_2$ bins, Centrality 40-50%.
$v_{2}$ data for various $q_3$ bins, Centrality 0-5%.
$v_{3}$ data for various $q_3$ bins, Centrality 0-5%.
$v_{4}$ data for various $q_3$ bins, Centrality 0-5%.
$v_{5}$ data for various $q_3$ bins, Centrality 0-5%.
$v_{2}$ data for various $q_3$ bins, Centrality 5-10%.
$v_{3}$ data for various $q_3$ bins, Centrality 5-10%.
$v_{4}$ data for various $q_3$ bins, Centrality 5-10%.
$v_{5}$ data for various $q_3$ bins, Centrality 5-10%.
$v_{2}$ data for various $q_3$ bins, Centrality 10-15%.
$v_{3}$ data for various $q_3$ bins, Centrality 10-15%.
$v_{4}$ data for various $q_3$ bins, Centrality 10-15%.
$v_{5}$ data for various $q_3$ bins, Centrality 10-15%.
$v_{2}$ data for various $q_3$ bins, Centrality 15-20%.
$v_{3}$ data for various $q_3$ bins, Centrality 15-20%.
$v_{4}$ data for various $q_3$ bins, Centrality 15-20%.
$v_{5}$ data for various $q_3$ bins, Centrality 15-20%.
$v_{2}$ data for various $q_3$ bins, Centrality 20-25%.
$v_{3}$ data for various $q_3$ bins, Centrality 20-25%.
$v_{4}$ data for various $q_3$ bins, Centrality 20-25%.
$v_{5}$ data for various $q_3$ bins, Centrality 20-25%.
$v_{2}$ data for various $q_3$ bins, Centrality 25-30%.
$v_{3}$ data for various $q_3$ bins, Centrality 25-30%.
$v_{4}$ data for various $q_3$ bins, Centrality 25-30%.
$v_{5}$ data for various $q_3$ bins, Centrality 25-30%.
$v_{2}$ data for various $q_3$ bins, Centrality 30-35%.
$v_{3}$ data for various $q_3$ bins, Centrality 30-35%.
$v_{4}$ data for various $q_3$ bins, Centrality 30-35%.
$v_{5}$ data for various $q_3$ bins, Centrality 30-35%.
$v_{2}$ data for various $q_3$ bins, Centrality 35-40%.
$v_{3}$ data for various $q_3$ bins, Centrality 35-40%.
$v_{4}$ data for various $q_3$ bins, Centrality 35-40%.
$v_{5}$ data for various $q_3$ bins, Centrality 35-40%.
$v_{2}$ data for various $q_3$ bins, Centrality 40-45%.
$v_{3}$ data for various $q_3$ bins, Centrality 40-45%.
$v_{4}$ data for various $q_3$ bins, Centrality 40-45%.
$v_{5}$ data for various $q_3$ bins, Centrality 40-45%.
$v_{2}$ data for various $q_3$ bins, Centrality 45-50%.
$v_{3}$ data for various $q_3$ bins, Centrality 45-50%.
$v_{4}$ data for various $q_3$ bins, Centrality 45-50%.
$v_{5}$ data for various $q_3$ bins, Centrality 45-50%.
$v_{2}$ data for various $q_3$ bins, Centrality 50-55%.
$v_{3}$ data for various $q_3$ bins, Centrality 50-55%.
$v_{4}$ data for various $q_3$ bins, Centrality 50-55%.
$v_{5}$ data for various $q_3$ bins, Centrality 50-55%.
$v_{2}$ data for various $q_3$ bins, Centrality 55-60%.
$v_{3}$ data for various $q_3$ bins, Centrality 55-60%.
$v_{4}$ data for various $q_3$ bins, Centrality 55-60%.
$v_{5}$ data for various $q_3$ bins, Centrality 55-60%.
$v_{2}$ data for various $q_3$ bins, Centrality 60-65%.
$v_{3}$ data for various $q_3$ bins, Centrality 60-65%.
$v_{4}$ data for various $q_3$ bins, Centrality 60-65%.
$v_{5}$ data for various $q_3$ bins, Centrality 60-65%.
$v_{2}$ data for various $q_3$ bins, Centrality 65-70%.
$v_{3}$ data for various $q_3$ bins, Centrality 65-70%.
$v_{4}$ data for various $q_3$ bins, Centrality 65-70%.
$v_{5}$ data for various $q_3$ bins, Centrality 65-70%.
$v_{2}$ data for various $q_3$ bins, Centrality 0-10%.
$v_{3}$ data for various $q_3$ bins, Centrality 0-10%.
$v_{4}$ data for various $q_3$ bins, Centrality 0-10%.
$v_{5}$ data for various $q_3$ bins, Centrality 0-10%.
$v_{2}$ data for various $q_3$ bins, Centrality 10-20%.
$v_{3}$ data for various $q_3$ bins, Centrality 10-20%.
$v_{4}$ data for various $q_3$ bins, Centrality 10-20%.
$v_{5}$ data for various $q_3$ bins, Centrality 10-20%.
$v_{2}$ data for various $q_3$ bins, Centrality 20-30%.
$v_{3}$ data for various $q_3$ bins, Centrality 20-30%.
$v_{4}$ data for various $q_3$ bins, Centrality 20-30%.
$v_{5}$ data for various $q_3$ bins, Centrality 20-30%.
$v_{2}$ data for various $q_3$ bins, Centrality 30-40%.
$v_{3}$ data for various $q_3$ bins, Centrality 30-40%.
$v_{4}$ data for various $q_3$ bins, Centrality 30-40%.
$v_{5}$ data for various $q_3$ bins, Centrality 30-40%.
$v_{2}$ data for various $q_3$ bins, Centrality 40-50%.
$v_{3}$ data for various $q_3$ bins, Centrality 40-50%.
$v_{4}$ data for various $q_3$ bins, Centrality 40-50%.
$v_{5}$ data for various $q_3$ bins, Centrality 40-50%.
$v_{2}$ - $v_{2}$ inclusive correlation in 5% centrality intervals.
$v_{2}$ - $v_{2}$ correlation within each centrality.
$v_{2}$ - $v_{2}$ inclusive correlation in 5% centrality intervals.
$v_{2}$ - $v_{2}$ correlation within each centrality.
$v_{2}$ - $v_{2}$ inclusive correlation in 5% centrality intervals.
$v_{2}$ - $v_{2}$ correlation within each centrality.
$v_{2}$ - $v_{2}$ inclusive correlation in 5% centrality intervals.
$v_{2}$ - $v_{2}$ correlation within each centrality.
$v_{2}$ - $v_{2}$ inclusive correlation in 5% centrality intervals.
$v_{2}$ - $v_{2}$ correlation within each centrality.
$v_{3}$ - $v_{3}$ inclusive correlation in 5% centrality intervals.
$v_{3}$ - $v_{3}$ correlation within each centrality.
$v_{3}$ - $v_{3}$ inclusive correlation in 5% centrality intervals.
$v_{3}$ - $v_{3}$ correlation within each centrality.
$v_{3}$ - $v_{3}$ inclusive correlation in 5% centrality intervals.
$v_{3}$ - $v_{3}$ correlation within each centrality.
$v_{3}$ - $v_{3}$ inclusive correlation in 5% centrality intervals.
$v_{3}$ - $v_{3}$ correlation within each centrality.
$v_{2}$ - $v_{3}$ inclusive correlation in 5% centrality intervals.
$v_{2}$ - $v_{3}$ correlation for various q2 bins within each centrality.
$v_{2}$ - $v_{3}$ inclusive correlation in 5% centrality intervals.
$v_{2}$ - $v_{3}$ correlation for various q2 bins within each centrality.
$v_{2}$ - $v_{3}$ inclusive correlation in 5% centrality intervals.
$v_{2}$ - $v_{3}$ correlation for various q2 bins within each centrality.
$v_{2}$ - $v_{3}$ inclusive correlation in 5% centrality intervals.
$v_{2}$ - $v_{3}$ correlation for various q2 bins within each centrality.
linear fit result of $v_{2}$ - $v_{3}$ correlation within each centrality.
$v_{3}$ - $v_{2}$ inclusive correlation in 5% centrality intervals.
$v_{3}$ - $v_{2}$ correlation for various q3 bins within each centrality.
$v_{3}$ - $v_{2}$ inclusive correlation in 5% centrality intervals.
$v_{3}$ - $v_{2}$ correlation for various q3 bins within each centrality.
$v_{3}$ - $v_{2}$ inclusive correlation in 5% centrality intervals.
$v_{3}$ - $v_{2}$ correlation for various q3 bins within each centrality.
$v_{3}$ - $v_{2}$ inclusive correlation in 5% centrality intervals.
$v_{3}$ - $v_{2}$ correlation for various q3 bins within each centrality.
$v_{2}$ - $v_{4}$ inclusive correlation in 5% centrality intervals.
$v_{2}$ - $v_{4}$ correlation for various q2 bins within each centrality.
$v_{2}$ - $v_{4}$ inclusive correlation in 5% centrality intervals.
$v_{2}$ - $v_{4}$ correlation for various q2 bins within each centrality.
$v_{2}$ - $v_{4}$ inclusive correlation in 5% centrality intervals.
$v_{2}$ - $v_{4}$ correlation for various q2 bins within each centrality.
$v_{2}$ - $v_{4}$ inclusive correlation in 5% centrality intervals.
$v_{2}$ - $v_{4}$ correlation for various q2 bins within each centrality.
$v_{3}$ - $v_{4}$ inclusive correlation in 5% centrality intervals.
$v_{3}$ - $v_{4}$ correlation within each centrality.
$v_{3}$ - $v_{4}$ inclusive correlation in 5% centrality intervals.
$v_{3}$ - $v_{4}$ correlation within each centrality.
$v_4$ decomposed into linear and nonlinear contributions based on q2 event-shape selection.
$v_4$ decomposed into linear and nonlinear contributions based on q2 event-shape selection.
$v_4$ decomposed into linear and nonlinear contributions based on q2 event-shape selection.
$v_4$ decomposed into linear and nonlinear contributions based on q2 event-shape selection.
$v_4$ decomposed into linear and nonlinear contributions based on q2 event-shape selection.
$v_5$ decomposed into linear and nonlinear contributions based on q2 event-shape selection.
$v_5$ decomposed into linear and nonlinear contributions based on q3 event-shape selection.
RMS eccentricity scaled v_n.
RMS eccentricity scaled v_n.
$v_{2}$ - $v_{5}$ inclusive correlation in 5% centrality intervals.
$v_{2}$ - $v_{5}$ correlation for various q2 bins within each centrality.
$v_{3}$ - $v_{5}$ inclusive correlation in 5% centrality intervals.
$v_{3}$ - $v_{5}$ correlation for various q2 bins within each centrality.
New PHENIX measurements of the anisotropic flow coefficients $v_2\{\Psi_2\}$, $v_3\{\Psi_3\}$, $v_4\{\Psi_4\}$ and $v_4\{\Psi_2\}$ for identified particles ($\pi^{\pm}$, $K^{\pm}$, and $p+\bar{p}$) obtained relative to the event planes $\Psi_n$ in Au$+$Au collisions at $\sqrt{s_{_{NN}}}$ = 200 GeV are presented as functions of collision centrality and particle transverse momenta $p_T$. The $v_n$ coefficients show characteristic patterns consistent with hydrodynamical expansion of the matter produced in the collisions. For each harmonic $n$, a modified valence quark number $n_q$ scaling plotting $v_n/(n_q)^{n/2}$ versus ${\rm KE}_T/n_q$ is observed to yield a single curve for all the measured particle species for a broad range of transverse kinetic energies ${\rm KE}_T$. A simultaneous blast wave model fit to the observed particle spectra and $v_n(p_T)$ coefficients identifies spatial eccentricities $s_n$ at freeze-out, which are much smaller than the initial-state geometric values.
Azimuthal anisotropy $v_n$ via the event-plane method for charge-combined $\pi^{\pm}$ in 0%–50% central Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Azimuthal anisotropy $v_2$ and $v_3$ via the two-particle correlation method for charge-combined $\pi^{\pm}$ in 0%–50% central Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Azimuthal anisotropy $v_4$ via the two-particle correlation method for charge-combined $\pi^{\pm}$ in 0%–50% central Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Azimuthal anisotropy $v_n$ via the event-plane method for charge-combined $K^{\pm}$ in 0%–50% central Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Azimuthal anisotropy $v_2$ and $v_3$ via the two-particle correlation method for charge-combined $K^{\pm}$ in 0%–50% central Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Azimuthal anisotropy $v_4$ via the two-particle correlation method for charge-combined $K^{\pm}$ in 0%–50% central Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Azimuthal anisotropy $v_n$ via the event-plane method for charge-combined $p\bar{p}$ in 0%–50% central Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Azimuthal anisotropy $v_2$ and $v_3$ via the two-particle correlation method for charge-combined $p\bar{p}$ in 0%–50% central Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Azimuthal anisotropy $v_4$ via the two-particle correlation method for charge-combined $p\bar{p}$ in 0%–50% central Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Azimuthal anisotropy $v_n$ via the event-plane method for charge-combined $\pi^{\pm}$ in 0%–10% central Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Azimuthal anisotropy $v_n$ via the event-plane method for charge-combined $\pi^{\pm}$ in 30%–50% central Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Azimuthal anisotropy $v_n$ via the event-plane method for charge-combined $K^{\pm}$ in 0%–10% central Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Azimuthal anisotropy $v_n$ via the event-plane method for charge-combined $K^{\pm}$ in 30%–50% central Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Azimuthal anisotropy $v_n$ via the event-plane method for charge-combined $p\bar{p}$ in 0%–10% central Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Azimuthal anisotropy $v_n$ via the event-plane method for charge-combined $p\bar{p}$ in 30%–50% central Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Freeze-out temperature $T_f$ in the blast-wave model fit to azimuthal anisotropy and invariant yields in Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Radially averaged flow rapidity $<\rho>$ in the blast-wave model fit to azimuthal anisotropy and invariant yields in Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Radial flow rapidity anisotropy $\rho_n$ in the blast-wave model fit to azimuthal anisotropy $v_2$ and invariant yields in Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Radial flow rapidity anisotropy $\rho_n$ in the blast-wave model fit to azimuthal anisotropy $v_3$ and invariant yields in Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Radial flow rapidity anisotropy $\rho_n$ in the blast-wave model fit to azimuthal anisotropy $v_4$ and invariant yields in Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Radial flow rapidity anisotropy $\rho_n$ in the blast-wave model fit to azimuthal anisotropy $v_4\{\Psi_2\}$ and invariant yields in Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Spatial anisotropy $s_n$ in the blast-wave model fit to azimuthal anisotropy $v_2$ and invariant yields in Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Spatial anisotropy $s_n$ in the blast-wave model fit to azimuthal anisotropy $v_3$ and invariant yields in Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Spatial anisotropy $s_n$ in the blast-wave model fit to azimuthal anisotropy $v_4$ and invariant yields in Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Spatial anisotropy $s_n$ in the blast-wave model fit to azimuthal anisotropy $v_4\{\Psi_2\}$ and invariant yields in Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Azimuthal anisotropy $v_n$ via the event-plane method for charge-combined $\pi^{\pm}$ in 10%–20% central Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Azimuthal anisotropy $v_n$ via the event-plane method for charge-combined $\pi^{\pm}$ in 20%–30% central Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Azimuthal anisotropy $v_n$ via the event-plane method for charge-combined $\pi^{\pm}$ in 30%–40% central Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Azimuthal anisotropy $v_n$ via the event-plane method for charge-combined $\pi^{\pm}$ in 40%–50% central Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Azimuthal anisotropy $v_n$ via the event-plane method for charge-combined $\pi^{\pm}$ in 50%–60% central Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Azimuthal anisotropy $v_n$ via the event-plane method for charge-combined $K^{\pm}$ in 10%–20% central Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Azimuthal anisotropy $v_n$ via the event-plane method for charge-combined $K^{\pm}$ in 20%–30% central Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Azimuthal anisotropy $v_n$ via the event-plane method for charge-combined $K^{\pm}$ in 30%–40% central Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Azimuthal anisotropy $v_n$ via the event-plane method for charge-combined $K^{\pm}$ in 40%–50% central Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Azimuthal anisotropy $v_n$ via the event-plane method for charge-combined $K^{\pm}$ in 50%–60% central Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Azimuthal anisotropy $v_n$ via the event-plane method for charge-combined $p\bar{p}$ in 10%–20% central Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Azimuthal anisotropy $v_n$ via the event-plane method for charge-combined $p\bar{p}$ in 20%–30% central Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Azimuthal anisotropy $v_n$ via the event-plane method for charge-combined $p\bar{p}$ in 30%–40% central Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Azimuthal anisotropy $v_n$ via the event-plane method for charge-combined $p\bar{p}$ in 40%–50% central Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Azimuthal anisotropy $v_n$ via the event-plane method for charge-combined $p\bar{p}$ in 50%–60% central Au+Au collisions at $\sqrt{s_{NN}} =$ 200 GeV.
Flow coefficients v_n for n = 2, 3, 4, characterizing the anisotropic collective flow in Au+Au collisions at sqrt(s_NN) = 200 GeV, are measured relative to event planes Ψ_n determined at large rapidity. We report v_n as a function of transverse momentum and collision centrality, and study the correlations among the event planes of different order n. The v_n are well described by hydrodynamic models which employ a Glauber Monte Carlo initial state geometry with fluctuations, providing additional constraining power on the interplay between initial conditions and the effects of viscosity as the system evolves. This new constraint improves precision of the extracted viscosity to entropy density ratio eta/s.
Charged hadron azimuthal anisotropy $v_2$, $v_3$, and $v_4$ vs $p_T$ in 0-10% central Au+Au collisions at 200 GeV. The mean $<p_T>$ in each $p_T$ bins used for the $v_n$ measurement is shown in Fig.2.6.
Charged hadron azimuthal anisotropy $v_2$, $v_3$, and $v_4$ vs $p_T$ in 10-20% central Au+Au collisions at 200 GeV. The mean $<p_T>$ in each $p_T$ bins used for the $v_n$ measurement is shown in Fig.2.6.
Charged hadron azimuthal anisotropy $v_2$, $v_3$, and $v_4$ vs $p_T$ in 20-30% central Au+Au collisions at 200 GeV. The mean $<p_T>$ in each $p_T$ bins used for the $v_n$ measurement is shown in Fig.2.6.
Charged hadron azimuthal anisotropy $v_2$, $v_3$, and $v_4$ vs $p_T$ in 30-40% central Au+Au collisions at 200 GeV. The mean $<p_T>$ in each $p_T$ bins used for the $v_n$ measurement is shown in Fig.2.6.
Charged hadron azimuthal anisotropy $v_2$, $v_3$, and $v_4$ vs $p_T$ in 40-50% central Au+Au collisions at 200 GeV. The mean $<p_T>$ in each $p_T$ bins used for the $v_n$ measurement is shown in Fig.2.6.
Charged hadron azimuthal anisotropy $v_2$, and $v_3$ vs $p_T$ in 50-60% central Au+Au collisions at 200 GeV. The mean $<p_T>$ in each $p_T$ bins used for the $v_n$ measurement is shown in Fig.2.6.
Charged hadron mean $<p_T>$ in each $p_T$ bins used for the $v_n$ measurements in Au+Au collisions at 200 GeV.
Charged hadron azimuthal anisotropy $v_2$ and $v_3$ vs centrality in Au+Au collisions at 200 GeV. The corresponding Npart value to each centrality is shown in Fig.3.2.
Charged hadron azimuthal anisotropy $v_4$ vs centrality in Au+Au collisions at 200 GeV. The corresponding Npart value to each centrality is shown in Fig.3.2.
Npart in each centrality bin in Au+Au collisions at 200 GeV.
When you search on a word, e.g. 'collisions', we will automatically search across everything we store about a record. But sometimes you may wish to be more specific. Here we show you how.
Guidance on the query string syntax can also be found in the OpenSearch documentation.
We support searching for a range of records using their HEPData record ID or Inspire ID.
About HEPData Submitting to HEPData HEPData File Formats HEPData Coordinators HEPData Terms of Use HEPData Cookie Policy
Status
Email
Forum
Twitter
GitHub
Copyright ~1975-Present, HEPData | Powered by Invenio, funded by STFC, hosted and originally developed at CERN, supported and further developed at IPPP Durham.