An experimental study of b-quark jets using high- p T electrons was carried out at √ s =58 GeV with the TOPAZ detector at the e + e − collider TRISTAN at KEK. The forward-backward charge asymmetry of the b-quark was obtained to be A b b ̄ =−0.55±0.27( stat. )±0.07( syst. ) , consistent with the standard model prediction. Also, such jet properties of the b-quark as the average charged multiplicity and the rapidity of charged particles were analyzed. In order to purify the b-quark event samples in this analysis, only events with backward-going electrons or forward-going positrons were used. The energy dependence of these jet properties was studied by making comparisons with the results of the DELCO experiment at the PEP collider (√ s =29 GeV) at SLAC.
No description provided.
No description provided.
Mean values of jet properties for b-jet sample.
We present a measurement of the cross section for production of isolated prompt photons in p¯p collisions at √s =1.8 TeV. The cross section, measured as a function of transverse momentum (PT), agrees qualitatively with QCD calculations but has a steeper slope at low PT.
Additional normalization systematic uncertainty of 27 pct for first eleven entries, and +32 pct(-46 pct) for last four entries.
We have measured the cross section for γγ production with the TOPAZ detector in the energy region √ s =50.0–61.4 GeV. The observed cross section for γγ production integrated over |cos θ | ⩽ 0.77 is 50.2±0.8±2.2 pb at 〈√ s 〉=57.6 GeV and the ratio of this value to the QED prediction is 1.01±0.02±0.04. The angular distribution is in good agreement with the QED predictions, thereby setting limits on the compositeness scales, Λ L+R + =168 GeV, Λ L+R − =97 GeV, Λ L,R =141 GeV, Λ L,R − =81 GeV, and Λ L−R ± =68 GeV, at the 95% confidence level. The reaction e + e − → γγγ was also studied and was found consistent with the QED prediction.
No description provided.
No description provided.
No description provided.
We have measured the forward-backward charge asymmetry in the process of b-quark production in e + e − annihilation at TRISTAN. It was made possible by detecting prompt leptons from b-quarks. The obtained asymmetry is A = −0.55±0.15±0.08. If corrected for B-meson mixing effects with the assumptions given in the text, the asymmetry becomes A = f −0.78±0.21±0.11, which is consistent with the prediction of the standard model, namely the assignment of the b-quark to the isospin doublet of the third quark generation.
Data uncorrected for meson mixing effects.
Data corrected for meson mixing effects.
The forward-backward asymmetry of charm quark production has been measured at an average of energy of 58.4 GeV with the VENUS detector at the TRISTAN e + e - collider. The charm quarks were identified through reconstruction of charged D ∗ mesons using the mass difference between the D ∗ and D 0 mesons. The measured charge asymmetry, -0.49 +.019 −0.17 ±0.04, is consistent with the prediction of the standard theory. The corresponding axial-vector coupling constant is 1.03 +0.40 −0.35 ±0.07.
No description provided.
Axial-vector coupling constant. Paper gives result for 2*GA.
We have collected 122 multi-hadronic inclusive muon events with the TOPAZ detector at 〈 s 〉 = 58.27 GeV with ∫ L d t=40.61 pb −1 . From this event sample we derived the differential cross section for B-hadron productions and determined B-hadron forward-backward asymmetry (A b b ) to be A b b = −0.71 ± 0.34 ( stat ) +0.07 −0.08 ( syst ) . A fit to the differential cross section, after correcting for the effect of B 0 B 0 mixing, yielded the axial-vector coupling constant of the b-quark ( a b ): a b = −1.79 +0.34 −0.32 (stat) +0.15 −0.14 (syst). We also set a 90% confidence level limit of χ <0.37 on the B 0 B 0 mixing parameter.
Observed differential cross section.
No description provided.
No description provided.
The charge asymmetry of quark jets produced in e + e − annihilations at 〈√ s 〉=57.9 GeV was measured with the TOPAZ detector at TRISTAN. The observed charge asymmetry is +0.091±0.014(stat.)±0.016(sys.). From the measured differential cross section, the axial vector coupling constant averaged over all quark flavors was determined to be 1.09 −0.21 +0.27 . These values are consistent with the standard model predictions. Possible deviations from the standard model were examined in terms of contact interactions, and the lower limits on the compositeness scale parameters were obtained to be 1.2–7.1 TeV at the 95% confidence level.
No description provided.
No description provided.
None
No description provided.
No description provided.
No description provided.
We have tested extra Z models in the reactions e + e − → μ + μ − , τ + τ − and hadrons in the energy range 50< s <64 GeV using the VENUS detector at the TRISTAN e + e − storage ring. Our data are in good agreement with the standard model prediction ( χ 2 N Df = 2.9 31 ) ). We have obtained 90% confidence-level lower limits of 105, 125 and 231 GeV for the masses of Z Ψ , Z η and Z χ bosons which are expected from the E 6 grand unified theory. We also place a 90% confidence-level lower limit of 426 GeV for the mass of an extra-Z boson whose couplings to quarks and leptons are assumed to be the same as those for the standard Z boson. Our results exceed the previous experimental limits from the p p collider experiments, although there have been some combined analyses reporting the limits better than those obtained in the present analysis.
New measurements.
New measurements. Statistical and systematic errors combined in quadrature.
New measurements.
We present the charged-particle multiplicity distributions for e+e− annihilation at center-of-mass energies from 50 to 61.4 GeV. The results are based on a data sample corresponding to a total integrated luminosity of 30 pb−1 obtained with the AMY detector at the KEK storage ring TRISTAN. The charged-particle multiplicity distributions deviate significantly from the modified Poisson and pair Poisson distributions, but follow Koba-Nielsen-Olesen scaling and are well reproduced by the LUND parton-shower model.
Fully corrected charged particle multiplicity distributions. Errors for n=2 and 4 are systematic only since these were derived using the LUND 6.3 Monte Carlo normalized to the observations at higher n values.
No description provided.