The process e+ e- -> phi -> K+ K- has been studied with the CMD-2 detector using about 542 000 events detected in the center-of-mass energy range from 1.01 to 1.034 GeV. The systematic error of the cross section is estimated to be 2.2%. The phi(1020) meson parameters in the phi -> K+K- decay channel have been measured: sigma_0(phi-> K+K-) = 2016 +- 8 +- 44 nb, m(phi) = 1019.441 +- 0.008 +- 0.080 MeV/c2, Gamma(phi) = 4.24 +- 0.02 +- 0.03 MeV, B(e+e-)B(K+K-) = (14.27 +- 0.05 +- 0.31)*10(-5).
Cross section measurement from the first energy scan.
Cross section measurement from the second energy scan.
The process $e^+e^- \to K^0_L K^0_S$ has been studied with the CMD-2 detector using about 950 events detected in the center-of-mass energy range from 1.05 to 1.38 GeV. The cross section exceeds the expectation based on the contributions of the rho(770), omega(782) and phi(1020) mesons only.
Measured cross section and 'bare' cross section for the process E+ E- --> KL KS.
About 300 000 $e^+e^-\to \phi\to K^0_L K^0_S$ events in the center of mass energy range from 984 to 1040 MeV were used for the measurement of the $\phi$ meson parameters. The following results have been obtained: $\sigma_0 = (1367 \pm 15 \pm 21) nb, m_{\phi}=(1019.504 \pm 0.011 \pm 0.033) MeV/c^2, \Gamma_\phi=(4.477 \pm 0.036 \pm 0.022) MeV, \Gamma_{e^+e^-}\cdot B(\phi\to K^0_L K^0_S) = (4.364 \pm 0.048 \pm 0.065)\cdot 10^{-4}$ MeV.
Updated measurements of the E+ E- --> PHI --> K0L K0S measured and 'bare' cross sections for SCAN 1.
Updated measurements of the E+ E- --> PHI --> K0L K0S measured and 'bare' cross sections for SCAN 2.
Updated measurements of the E+ E- --> PHI --> K0L K0S measured and 'bare' cross sections for SCAN 3.
Results of the measurement of the φ meson parameters with the general purpose detector CMD-2 at the upgraded e + e − collider VEPP-2M at Novosibirsk are presented. This is the first measurement of the four major φ decay modes in a single e + e − experiment. The results based on about 55,600 identified hadronic events are consistent with previous measurements, and have precision comparable to the current world average.
No description provided.
None
No description provided.
No description provided.
No description provided.
None
Axis error includes +- 7/7 contribution (/LUMINOCITY, RADIATIVE CORRECTIONS, NUCLEAR ABSORPTION AND DECAY IN FLIGHT).