Showing 10 of 14 results
In high-energy heavy-ion collisions, partonic collectivity is evidenced by the constituent quark number scaling of elliptic flow anisotropy for identified hadrons. A breaking of this scaling and dominance of baryonic interactions is found for identified hadron collective flow measurements in $\sqrt{s_{\rm NN}}$ = 3 GeV Au+Au collisions. In this paper, we report measurements of the first- and second-order azimuthal anisotropic parameters, $v_1$ and $v_2$, of light nuclei ($d$, $t$, $^{3}$He, $^{4}$He) produced in $\sqrt{s_{\rm NN}}$ = 3 GeV Au+Au collisions at the STAR experiment. An atomic mass number scaling is found in the measured $v_1$ slopes of light nuclei at mid-rapidity. For the measured $v_2$ magnitude, a strong rapidity dependence is observed. Unlike $v_2$ at higher collision energies, the $v_2$ values at mid-rapidity for all light nuclei are negative and no scaling is observed with the atomic mass number. Calculations by the Jet AA Microscopic Transport Model (JAM), with baryonic mean-field plus nucleon coalescence, are in good agreement with our observations, implying baryonic interactions dominate the collective dynamics in 3 GeV Au+Au collisions at RHIC.
Elliptic flow (v_2) values for identified particles at midrapidity in Au + Au collisions measured by the STAR experiment in the Beam Energy Scan at the Relativistic Heavy Ion Collider at sqrt{s_{NN}}= 7.7--62.4 GeV are presented for three centrality classes. The centrality dependence and the data at sqrt{s_{NN}}= 14.5 GeV are new. Except at the lowest beam energies we observe a similar relative v_2 baryon-meson splitting for all centrality classes which is in agreement within 15% with the number-of-constituent quark scaling. The larger v_2 for most particles relative to antiparticles, already observed for minimum bias collisions, shows a clear centrality dependence, with the largest difference for the most central collisions. Also, the results are compared with A Multiphase Transport Model and fit with a Blast Wave model.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
No description provided.
We report systematic measurements of bulk properties of the system created in Au+Au collisions at $\sqrt{s_{\mathrm{NN}}}$ = 14.5 GeV recorded by the STAR detector at the Relativistic Heavy Ion Collider (RHIC).The transverse momentum spectra of $\pi^{\pm}$, $K^{\pm}$ and $p(\bar{p})$ are studied at mid-rapidity ($|y| < 0.1$) for nine centrality intervals. The centrality, transverse momentum ($p_T$),and pseudorapidity ($\eta$) dependence of inclusive charged particle elliptic flow ($v_2$), and rapidity-odd charged particles directed flow ($v_{1}$) results near mid-rapidity are also presented. These measurements are compared with the published results from Au+Au collisions at other energies, and from Pb+Pb collisions at $\sqrt{s_{\mathrm{NN}}}$ = 2.76 TeV. The results at $\sqrt{s_{\mathrm{NN}}}$ = 14.5 GeV show similar behavior as established at other energies and fit well in the energy dependence trend. These results are important as the 14.5 GeV energy fills the gap in $\mu_B$, which is of the order of 100 MeV,between $\sqrt{s_{\mathrm{NN}}}$ =11.5 and 19.6 GeV. Comparisons of the data with UrQMD and AMPT models show poor agreement in general.
We report on the first measurement of the azimuthal anisotropy ($v_2$) of dielectrons ($e^{+}e^{-}$ pairs) at mid-rapidity from $\sqrt{s_{_{NN}}} = 200$ GeV Au+Au collisions with the STAR detector at RHIC, presented as a function of transverse momentum ($p_T$) for different invariant-mass regions. In the mass region $M_{ee}\!<1.1$ GeV/$c^2$ the dielectron $v_2$ measurements are found to be consistent with expectations from $\pi^{0}$, $\eta$, $\omega$ and $\phi$ decay contributions. In the mass region $1.1\!<M_{ee}\!<2.9$ GeV/$c^2$, the measured dielectron $v_2$ is consistent, within experimental uncertainties, with that from the $c\bar{c}$ contributions.
Measurements of the azimuthal anisotropy in lead-lead collisions at $\sqrt{s_\mathrm{NN}} = 5.02$ TeV are presented using a data sample corresponding to 0.49 $\mathrm{nb}^{-1}$ integrated luminosity collected by the ATLAS experiment at the LHC in 2015. The recorded minimum-bias sample is enhanced by triggers for "ultra-central" collisions, providing an opportunity to perform detailed study of flow harmonics in the regime where the initial state is dominated by fluctuations. The anisotropy of the charged-particle azimuthal angle distributions is characterized by the Fourier coefficients, $v_{2}-v_{7}$, which are measured using the two-particle correlation, scalar-product and event-plane methods. The goal of the paper is to provide measurements of the differential as well as integrated flow harmonics $v_{n}$ over wide ranges of the transverse momentum, 0.5 $
The V2 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-0.1%
The V2 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-1%
The V2 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-5%
The V2 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 5-10%
The V2 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 10-20%
The V2 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 20-30%
The V2 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 30-40%
The V2 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 40-50%
The V2 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 50-60%
The V2 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 60-70%
The V2 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 70-80%
The V3 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-0.1%
The V3 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-1%
The V3 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-5%
The V3 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 5-10%
The V3 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 10-20%
The V3 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 20-30%
The V3 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 30-40%
The V3 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 40-50%
The V3 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 50-60%
The V3 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 60-70%
The V3 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 70-80%
The V4 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-0.1%
The V4 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-1%
The V4 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-5%
The V4 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 5-10%
The V4 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 10-20%
The V4 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 20-30%
The V4 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 30-40%
The V4 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 40-50%
The V4 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 50-60%
The V4 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 60-70%
The V4 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 70-80%
The V5 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-0.1%
The V5 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-1%
The V5 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-5%
The V5 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 5-10%
The V5 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 10-20%
The V5 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 20-30%
The V5 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 30-40%
The V5 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 40-50%
The V5 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 50-60%
The V5 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 60-70%
The V5 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 70-80%
The V6 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-5%
The V6 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 5-10%
The V6 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 10-20%
The V6 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 20-30%
The V6 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 30-40%
The V6 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 40-50%
The V6 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 50-60%
The V6 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 60-70%
The V6 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 70-80%
The V7 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 0-5%
The V7 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 5-10%
The V7 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 10-20%
The V7 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 20-30%
The V7 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 30-40%
The V7 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 40-50%
The V7 harmonic measured with the scalar product method as a funtion of transverse momentum in centrality bin 50-60%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 0-5%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 5-10%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 10-20%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 20-30%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 30-40%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 40-50%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 50-60%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 60-70%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 70-80%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 0-5%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 5-10%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 10-20%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 20-30%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 30-40%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 40-50%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 50-60%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 60-70%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 70-80%
The V4 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 0-5%
The V4 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 5-10%
The V4 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 10-20%
The V4 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 20-30%
The V4 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 30-40%
The V4 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 40-50%
The V4 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 50-60%
The V4 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 60-70%
The V4 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 70-80%
The V5 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 0-5%
The V5 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 5-10%
The V5 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 10-20%
The V5 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 20-30%
The V5 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 30-40%
The V5 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 40-50%
The V5 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 50-60%
The V5 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 60-70%
The V6 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 0-5%
The V6 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 5-10%
The V6 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 10-20%
The V6 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 20-30%
The V6 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 30-40%
The V6 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 40-50%
The V6 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 50-60%
The V6 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 60-70%
The ratio of V2{SP} over V2{EP} as a funtion of transverse momentum in centrality bin 0-5%
The ratio of V2{SP} over V2{EP} as a funtion of transverse momentum in centrality bin 20-30%
The ratio of V2{SP} over V2{EP} as a funtion of transverse momentum in centrality bin 40-50%
The ratio of V3{SP} over V3{EP} as a funtion of transverse momentum in centrality bin 0-5%
The ratio of V3{SP} over V3{EP} as a funtion of transverse momentum in centrality bin 20-30%
The ratio of V3{SP} over V3{EP} as a funtion of transverse momentum in centrality bin 40-50%
The ratio of V4{SP} over V4{EP} as a funtion of transverse momentum in centrality bin 0-5%
The ratio of V4{SP} over V4{EP} as a funtion of transverse momentum in centrality bin 20-30%
The ratio of V4{SP} over V4{EP} as a funtion of transverse momentum in centrality bin 40-50%
The ratio of V5{SP} over V5{EP} as a funtion of transverse momentum in centrality bin 0-5%
The ratio of V5{SP} over V5{EP} as a funtion of transverse momentum in centrality bin 20-30%
The ratio of V5{SP} over V5{EP} as a funtion of transverse momentum in centrality bin 40-50%
The ratio of V6{SP} over V6{EP} as a funtion of transverse momentum in centrality bin 0-5%
The ratio of V6{SP} over V6{EP} as a funtion of transverse momentum in centrality bin 20-30%
The ratio of V6{SP} over V6{EP} as a funtion of transverse momentum in centrality bin 40-50%
The ratio of V2{SP} over V2{EP} as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The ratio of V3{SP} over V3{EP} as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The ratio of V4{SP} over V4{EP} as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The ratio of V5{SP} over V5{EP} as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The ratio of V6{SP} over V6{EP} as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The ratio of V2{SP} over V2{2PC} as a funtion of transverse momentum in centrality bin 0-5%
The ratio of V2{SP} over V2{2PC} as a funtion of transverse momentum in centrality bin 20-30%
The ratio of V2{SP} over V2{2PC} as a funtion of transverse momentum in centrality bin 40-50%
The ratio of V3{SP} over V3{2PC} as a funtion of transverse momentum in centrality bin 0-5%
The ratio of V3{SP} over V3{2PC} as a funtion of transverse momentum in centrality bin 20-30%
The ratio of V3{SP} over V3{2PC} as a funtion of transverse momentum in centrality bin 40-50%
The ratio of V4{SP} over V4{2PC} as a funtion of transverse momentum in centrality bin 0-5%
The ratio of V4{SP} over V4{2PC} as a funtion of transverse momentum in centrality bin 20-30%
The ratio of V4{SP} over V4{2PC} as a funtion of transverse momentum in centrality bin 40-50%
The ratio of V5{SP} over V5{2PC} as a funtion of transverse momentum in centrality bin 0-5%
The ratio of V5{SP} over V5{2PC} as a funtion of transverse momentum in centrality bin 20-30%
The ratio of V5{SP} over V5{2PC} as a funtion of transverse momentum in centrality bin 40-50%
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-5%. PT binning matched to RUN1.
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 20-30%. PT binning matched to RUN1.
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 40-50%. PT binning matched to RUN1.
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-5%. PT binning matched to RUN1.
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 20-30%. PT binning matched to RUN1.
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 40-50%. PT binning matched to RUN1.
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-5%. PT binning matched to RUN1.
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 20-30%. PT binning matched to RUN1.
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 40-50%. PT binning matched to RUN1.
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-5%. PT binning matched to RUN1.
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 20-30%. PT binning matched to RUN1.
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 40-50%. PT binning matched to RUN1.
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-5%. PT binning matched to RUN1.
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 20-30%. PT binning matched to RUN1.
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 40-50%. PT binning matched to RUN1.
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-0.1%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-5%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 10-20%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 30-40%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 60-70%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-0.1%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-5%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 10-20%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 30-40%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 60-70%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-0.1%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-5%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 10-20%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 30-40%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 60-70%
The V5 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-0.1%
The V5 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-5%
The V5 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 10-20%
The V5 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 30-40%
The V5 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 60-70%
The V6 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-5%
The V6 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 10-20%
The V6 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 30-40%
The V6 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 60-70%
The V7 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 0-5%
The V7 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 10-20%
The V7 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 0.8 < PT < 1 GeV in centrality bin 30-40%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-0.1%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-5%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 10-20%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 30-40%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 60-70%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-0.1%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-5%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 10-20%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 30-40%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 60-70%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-0.1%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-5%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 10-20%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 30-40%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 60-70%
The V5 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-0.1%
The V5 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-5%
The V5 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 10-20%
The V5 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 30-40%
The V5 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 60-70%
The V6 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-5%
The V6 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 10-20%
The V6 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 30-40%
The V6 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 60-70%
The V7 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 0-5%
The V7 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 10-20%
The V7 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 2 < PT < 3 GeV in centrality bin 30-40%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 0-0.1%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 0-5%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 10-20%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 30-40%
The V2 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 60-70%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 0-0.1%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 0-5%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 10-20%
The V3 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 30-40%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 0-0.1%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 0-5%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 10-20%
The V4 harmonic measured with the scalar product method as a funtion of pseudorapidity for transverse momentum range 7 < PT < 60 GeV in centrality bin 30-40%
The V2 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 0.8 GeV
The V2 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.8 < PT < 1 GeV
The V2 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 1 < PT < 2 GeV
The V2 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 2 < PT < 4 GeV
The V2 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 4 < PT < 8 GeV
The V2 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 8 < PT < 60 GeV
The V2 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The V3 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 0.8 GeV
The V3 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.8 < PT < 1 GeV
The V3 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 1 < PT < 2 GeV
The V3 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 2 < PT < 4 GeV
The V3 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 4 < PT < 8 GeV
The V3 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 8 < PT < 60 GeV
The V3 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The V4 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 0.8 GeV
The V4 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.8 < PT < 1 GeV
The V4 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 1 < PT < 2 GeV
The V4 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 2 < PT < 4 GeV
The V4 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 4 < PT < 8 GeV
The V4 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 8 < PT < 60 GeV
The V4 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The V5 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 0.8 GeV
The V5 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.8 < PT < 1 GeV
The V5 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 1 < PT < 2 GeV
The V5 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 2 < PT < 4 GeV
The V5 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 4 < PT < 8 GeV
The V5 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 8 < PT < 60 GeV
The V5 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The V6 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 0.8 GeV
The V6 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.8 < PT < 1 GeV
The V6 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 1 < PT < 2 GeV
The V6 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 2 < PT < 4 GeV
The V6 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 4 < PT < 8 GeV
The V6 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 8 < PT < 60 GeV
The V6 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The V7 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 0.8 GeV
The V7 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.8 < PT < 1 GeV
The V7 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 1 < PT < 2 GeV
The V7 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 2 < PT < 4 GeV
The V7 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 4 < PT < 8 GeV
The V7 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 8 < PT < 60 GeV
The V7 harmonic measured with the scalar product method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 0-5%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 10-15%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 20-25%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 30-35%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 40-45%
The V2 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 50-55%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 0-5%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 10-15%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 20-25%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 30-35%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 40-45%
The V3 harmonic measured with the two particle correlation method as a funtion of transverse momentum in centrality bin 50-55%
The scaled-V2(PT) measured with the two particle correlation method in centrality bin 0-5%
The scaled-V2(PT) measured with the two particle correlation method in centrality bin 10-15%
The scaled-V2(PT) measured with the two particle correlation method in centrality bin 20-25%
The scaled-V2(PT) measured with the two particle correlation method in centrality bin 30-35%
The scaled-V2(PT) measured with the two particle correlation method in centrality bin 40-45%
The scaled-V2(PT) measured with the two particle correlation method in centrality bin 50-55%
The scaled-V3(PT) measured with the two particle correlation method in centrality bin 0-5%
The scaled-V3(PT) measured with the two particle correlation method in centrality bin 10-15%
The scaled-V3(PT) measured with the two particle correlation method in centrality bin 20-25%
The scaled-V3(PT) measured with the two particle correlation method in centrality bin 30-35%
The scaled-V3(PT) measured with the two particle correlation method in centrality bin 40-45%
The scaled-V3(PT) measured with the two particle correlation method in centrality bin 50-55%
The PT scale factor for V2(PT) as a funtion of collision centrality
The PT scale factor for V3(PT) as a funtion of collision centrality
The V2 scale factor as a funtion of collision centrality
The V3 scale factor as a funtion of collision centrality
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-0.1%
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-1%
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-5%
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 5-10%
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 10-20%
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 20-30%
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 30-40%
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 40-50%
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 50-60%
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 60-70%
The V2 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 70-80%
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-0.1%
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-1%
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-5%
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 5-10%
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 10-20%
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 20-30%
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 30-40%
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 40-50%
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 50-60%
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 60-70%
The V3 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 70-80%
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-0.1%
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-1%
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-5%
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 5-10%
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 10-20%
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 20-30%
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 30-40%
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 40-50%
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 50-60%
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 60-70%
The V4 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 70-80%
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-0.1%
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-1%
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-5%
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 5-10%
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 10-20%
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 20-30%
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 30-40%
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 40-50%
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 50-60%
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 60-70%
The V5 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 70-80%
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-5%
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 5-10%
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 10-20%
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 20-30%
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 30-40%
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 40-50%
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 50-60%
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 60-70%
The V6 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 70-80%
The V7 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 0-5%
The V7 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 5-10%
The V7 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 10-20%
The V7 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 20-30%
The V7 harmonic measured with the event plane method as a funtion of transverse momentum in centrality bin 30-40%
The V2 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 0.8 GeV
The V4 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 4 < PT < 8 GeV
The V4 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 8 < PT < 60 GeV
The V4 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 60 GeV
The V5 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.5 < PT < 0.8 GeV
The V5 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 0.8 < PT < 1 GeV
The V5 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 1 < PT < 2 GeV
The V5 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 2 < PT < 4 GeV
The V5 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 4 < PT < 8 GeV
The V5 harmonic measured with the event plane method as a funtion of MEAN(Npart) integrated over 8 < PT < 60 GeV
Dihadron angular correlations in $d$+Au collisions at $\sqrt{s_{\rm NN}}=200$ GeV are reported as a function of the measured zero-degree calorimeter neutral energy and the forward charged hadron multiplicity in the Au-beam direction. A finite correlated yield is observed at large relative pseudorapidity ($\Delta\eta$) on the near side (i.e. relative azimuth $\Delta\phi\sim0$). This correlated yield as a function of $\Delta\eta$ appears to scale with the dominant, primarily jet-related, away-side ($\Delta\phi\sim\pi$) yield. The Fourier coefficients of the $\Delta\phi$ correlation, $V_{n}=\langle\cos n\Delta\phi\rangle$, have a strong $\Delta\eta$ dependence. In addition, it is found that $V_{1}$ is approximately inversely proportional to the mid-rapidity event multiplicity, while $V_{2}$ is independent of it with similar magnitude in the forward ($d$-going) and backward (Au-going) directions.
Correlated dihadron yield, per radian per unit of pseudorapidity, as a function of $\Delta\phi$ for 1.2 < $|\Delta\eta|$ < 1.8 in d+Au collisions, for low ZDC-Au activity data. Both the trigger and associated particles have 1 < $p_T$ < 3 GeV/c.
Correlated dihadron yield, per radian per unit of pseudorapidity, as a function of $\Delta\phi$ for 1.2 < $|\Delta\eta|$ < 1.8 in d+Au collisions, for high ZDC-Au activity data. Both the trigger and associated particles have 1 < $p_T$ < 3 GeV/c.
Correlated dihadron yield, per radian per unit of pseudorapidity, as a function of $\Delta\phi$ for -4.5 < $\Delta\eta$ < -2 in d+Au collisions, for low ZDC-Au activity data. Both the trigger and associated particles have 1 < $p_T$ < 3 GeV/c.
Correlated dihadron yield, per radian per unit of pseudorapidity, as a function of $\Delta\phi$ for -4.5 < $\Delta\eta$ < -2 in d+Au collisions, for high ZDC-Au activity data. Both the trigger and associated particles have 1 < $p_T$ < 3 GeV/c.
Correlated dihadron yield, per radian per unit of pseudorapidity, as a function of $\Delta\phi$ for 2 < $\Delta\eta$ < 4.5 in d+Au collisions, for low ZDC-Au activity data. Both the trigger and associated particles have 1 < $p_T$ < 3 GeV/c.
Correlated dihadron yield, per radian per unit of pseudorapidity, as a function of $\Delta\phi$ for 2 < $\Delta\eta$ < 4.5 in d+Au collisions, for high ZDC-Au activity data. Both the trigger and associated particles have 1 < $p_T$ < 3 GeV/c.
The $\Delta\eta$ dependence of the near-side (|$\Delta\phi$| < $\pi/3$) correlated yield. Positive(negative) $\eta$ corresponds to d(Au)-going direction. Only high ZDC-Au activity data are shown.
The $\Delta\eta$ dependence of the away-side (|$\Delta\phi - \pi$| < $\pi/3$) correlated yield. Positive(negative) $\eta$ corresponds to d(Au)-going direction. Only high ZDC-Au activity data are shown.
The $\Delta\eta$ dependence of the ratio of the near- to away-side correlated yields in d+Au collisions. Positive(negative) $\eta$ corresponds to d(Au)-going direction. Only high ZDC-Au activity data are shown.
The $\Delta\eta$ dependence of the second harmonic Fourier coefficient, V2, in low ZDC-Au activity d+Au collisions.
The $\Delta\eta$ dependence of the second harmonic Fourier coefficient, V2, in high ZDC-Au activity d+Au collisions.
Fourier coefficient V1 versus the measured mid-rapidity charged particle $dN_{ch}/d\eta$. Event activity selection is by FTPC-Au. Trigger particles are from TPC, and associated particles from TPC. Systematic uncertainties are estimated to be 10% on V1. Errors shown are the quadratic sum of statistical and systematic errors.
Fourier coefficient V1 versus the measured mid-rapidity charged particle $dN_{ch}/d\eta$. Event activity selection is by ZDC. Trigger particles are from TPC, and associated particles from FTPC-Au. Systematic uncertainties are estimated to be 10% on V1. Errors shown are the quadratic sum of statistical and systematic errors.
Fourier coefficient V1 versus the measured mid-rapidity charged particle $dN_{ch}/d\eta$. Event activity selection is by ZDC. Trigger particles are from TPC, and associated particles from FTPC-d. Systematic uncertainties are estimated to be 10% on V1. Errors shown are the quadratic sum of statistical and systematic errors.
Fourier coefficient V1 versus the measured mid-rapidity charged particle $dN_{ch}/d\eta$. Event activity selection is by ZDC-Au. Trigger particles are from TPC, and associated particles from TPC. Systematic uncertainties are estimated to be 10% on V1. Errors shown are the quadratic sum of statistical and systematic errors.
Fourier coefficient V2 versus the measured mid-rapidity charged particle $dN_{ch}/d\eta$. Event activity selection is by FTPC-Au. Trigger particles are from TPC, and associated particles from TPC. Systematic uncertainties are estimated to be 10% on V2. Errors shown are the quadratic sum of statistical and systematic errors.
Fourier coefficient V2 versus the measured mid-rapidity charged particle $dN_{ch}/d\eta$. Event activity selection is by ZDC-Au. Trigger particles are from TPC, and associated particles from FTPC-Au. Systematic uncertainties are estimated to be 10% on V2. Errors shown are the quadratic sum of statistical and systematic errors.
Fourier coefficient V2 versus the measured mid-rapidity charged particle $dN_{ch}/d\eta$. Event activity selection is by ZDC-Au. Trigger particles are from TPC, and associated particles from FTPC-d. Systematic uncertainties are estimated to be 10% on V2. Errors shown are the quadratic sum of statistical and systematic errors.
Fourier coefficient V2 versus the measured mid-rapidity charged particle $dN_{ch}/d\eta$. Event activity selection is by ZDC-Au. Trigger particles are from TPC, and associated particles from TPC. Systematic uncertainties are estimated to be 10% on V2. Errors shown are the quadratic sum of statistical and systematic errors.
Fourier coefficient V3 versus the measured mid-rapidity charged particle $dN_{ch}/d\eta$. Event activity selections is by FTPC-Au. Trigger particles are from TPC, and associated particles from TPC. Systematic uncertainties are estimated to be smaller than statistical errors for V3. Errors shown are the quadratic sum of statistical and systematic errors.
Fourier coefficient V3 versus the measured mid-rapidity charged particle $dN_{ch}/d\eta$. Event activity selection is by ZDC-Au. Trigger particles are from TPC, and associated particles from FTPC-Au. Systematic uncertainties are estimated to be smaller than statistical errors for V3. Errors shown are the quadratic sum of statistical and systematic errors.
Fourier coefficient V3 versus the measured mid-rapidity charged particle $dN_{ch}/d\eta$. Event activity selection is by ZDC-Au. Trigger particles are from TPC, and associated particles from FTPC-d. Systematic uncertainties are estimated to be smaller than statistical errors for V3. Errors shown are the quadratic sum of statistical and systematic errors.
Fourier coefficient V3 versus the measured mid-rapidity charged particle $dN_{ch}/d\eta$. Event activity selection is by ZDC-Au. Trigger particles are from TPC, and associated particles from TPC. Systematic uncertainties are estimated to be smaller than statistical errors for V3. Errors shown are the quadratic sum of statistical and systematic errors.
We present measurements of $\pi^-$ and $\pi^+$ elliptic flow, $v_2$, at midrapidity in Au+Au collisions at $\sqrt{s_{_{\rm NN}}} =$ 200, 62.4, 39, 27, 19.6, 11.5 and 7.7 GeV, as a function of event-by-event charge asymmetry, $A_{ch}$, based on data from the STAR experiment at RHIC. We find that $\pi^-$ ($\pi^+$) elliptic flow linearly increases (decreases) with charge asymmetry for most centrality bins at $\sqrt{s_{_{\rm NN}}} = \text{27 GeV}$ and higher. At $\sqrt{s_{_{\rm NN}}} = \text{200 GeV}$, the slope of the difference of $v_2$ between $\pi^-$ and $\pi^+$ as a function of $A_{ch}$ exhibits a centrality dependence, which is qualitatively similar to calculations that incorporate a chiral magnetic wave effect. Similar centrality dependence is also observed at lower energies.
The distribution of observed charge asymmetry from STAR data.
Pion $v_2${2} as a function of observed charge asymmetry.
$v_2$ difference between $\pi^-$ and $\pi^+$ as a function of charge asymmetry with the tracking efficiency correction, for 30-40% central Au+Au collisions at 200 GeV. The errors are statistical only.
The slope parameter r as a function of centrality for collision energy of 200 GeV.
The slope parameter r as a function of centrality for collision energy of 62.4 GeV.
The slope parameter r as a function of centrality for collision energy of 39 GeV.
The slope parameter r as a function of centrality for collision energy of 27 GeV.
The slope parameter r as a function of centrality for collision energy of 19.6 GeV.
The slope parameter r as a function of centrality for collision energy of 11.5 GeV.
The slope parameter r as a function of centrality for collision energy of 7.7 GeV.
Collisions between prolate uranium nuclei are used to study how particle production and azimuthal anisotropies depend on initial geometry in heavy-ion collisions. We report the two- and four-particle cumulants, $v_2\{2\}$ and $v_2\{4\}$, for charged hadrons from U+U collisions at $\sqrt{s_{\rm NN}}$ = 193 GeV and Au+Au collisions at $\sqrt{s_{\rm NN}}$ = 200 GeV. Nearly fully overlapping collisions are selected based on the amount of energy deposited by spectators in the STAR Zero Degree Calorimeters (ZDCs). Within this sample, the observed dependence of $v_2\{2\}$ on multiplicity demonstrates that ZDC information combined with multiplicity can preferentially select different overlap configurations in U+U collisions. An initial-state model with gluon saturation describes the slope of $v_2\{2\}$ as a function of multiplicity in central collisions better than one based on Glauber with a two-component multiplicity model.
We present high precision measurements of elliptic flow near midrapidity ($|y|<1.0$) for multi-strange hadrons and $\phi$ meson as a function of centrality and transverse momentum in Au+Au collisions at center of mass energy $\sqrt{s_{NN}}=$ 200 GeV. We observe that the transverse momentum dependence of $\phi$ and $\Omega$ $v_{2}$ is similar to that of $\pi$ and $p$, respectively, which may indicate that the heavier strange quark flows as strongly as the lighter up and down quarks. This observation constitutes a clear piece of evidence for the development of partonic collectivity in heavy-ion collisions at the top RHIC energy. Number of constituent quark scaling is found to hold within statistical uncertainty for both 0-30$\%$ and 30-80$\%$ collision centrality. There is an indication of the breakdown of previously observed mass ordering between $\phi$ and proton $v_{2}$ at low transverse momentum in the 0-30$\%$ centrality range, possibly indicating late hadronic interactions affecting the proton $v_{2}$.
ATLAS measurements of the azimuthal anisotropy in lead-lead collisions at $\sqrt{s_{NN}}=2.76$ TeV are shown using a dataset of approximately 7 $\mu$b$^{-1}$ collected at the LHC in 2010. The measurements are performed for charged particles with transverse momenta $0.5<p_T<20$ GeV and in the pseudorapidity range $|\eta|<2.5$. The anisotropy is characterized by the Fourier coefficients, $v_n$, of the charged-particle azimuthal angle distribution for n = 2-4. The Fourier coefficients are evaluated using multi-particle cumulants calculated with the generating function method. Results on the transverse momentum, pseudorapidity and centrality dependence of the $v_n$ coefficients are presented. The elliptic flow, $v_2$, is obtained from the two-, four-, six- and eight-particle cumulants while higher-order coefficients, $v_3$ and $v_4$, are determined with two- and four-particle cumulants. Flow harmonics $v_n$ measured with four-particle cumulants are significantly reduced compared to the measurement involving two-particle cumulants. A comparison to $v_n$ measurements obtained using different analysis methods and previously reported by the LHC experiments is also shown. Results of measurements of flow fluctuations evaluated with multi-particle cumulants are shown as a function of transverse momentum and the collision centrality. Models of the initial spatial geometry and its fluctuations fail to describe the flow fluctuations measurements.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 0-2%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 2-5%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 5-10%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 10-15%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 15-20%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 20-25%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 25-30%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 30-35%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 35-40%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 40-45%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 45-50%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 50-55%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 55-60%.
The second flow harmonic measured with the two-particle cumulants as a function of transverse momentum in centrality bin 60-80%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 0-2%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 2-5%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 5-10%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 10-15%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 15-20%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 20-25%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 25-30%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 30-35%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 35-40%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 40-45%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 45-50%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 50-55%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 55-60%.
The second flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 60-80%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 2-5%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 5-10%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 10-15%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 15-20%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 20-25%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 25-30%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 30-35%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 35-40%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 40-45%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 45-50%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 50-55%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 55-60%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 60-80%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 2-5%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 5-10%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 10-15%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 15-20%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 20-25%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 25-30%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 30-35%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 35-40%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 40-45%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 45-50%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 50-55%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 55-60%.
The second flow harmonic measured with the six-particle cumulats as a function of transverse momentum in centrality bin 60-80%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 2-5%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 5-10%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 10-15%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 15-20%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 20-25%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 25-30%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 30-35%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 35-40%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 40-45%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 45-50%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 50-55%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 55-60%.
The second flow harmonic measured with the eight-particle cumulats as a function of transverse momentum in centrality bin 60-80%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 5-10%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 15-20%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 25-30%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 35-40%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 40-50%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 10-20%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 20-30%.
The second flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 30-40%.
The triangular flow harmonic measured with the two-particle cumulats as a function of transverse momentum in centrality bin 0-25%.
The triangular flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 0-25%.
The triangular flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 0-25%.
The triangular flow harmonic measured with the two-particle cumulats as a function of transverse momentum in centrality bin 25-60%.
The triangular flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 25-60%.
The triangular flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 25-60%.
The quadrangular flow harmonic measured with the two-particle cumulats as a function of transverse momentum in centrality bin 0-25%.
The quadrangular flow harmonic measured with the Event Plane method as a function of transverse momentum in centrality bin 0-25%.
The quadrangular flow harmonic measured with the four-particle cumulats as a function of transverse momentum in centrality bin 0-25%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 0-2%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 2-5%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 5-10%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 10-15%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 15-20%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 20-25%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 25-30%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 30-35%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 35-40%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 40-45%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 45-50%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 50-55%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 55-60%.
The second flow harmonic measured with the two-particle cumulants as a function of pseudorapidity in centrality bin 60-80%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 0-2%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 2-5%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 5-10%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 10-15%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 15-20%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 20-25%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 25-30%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 30-35%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 35-40%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 40-45%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 45-50%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 50-55%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 55-60%.
The second flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 60-80%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 2-5%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 5-10%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 10-15%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 15-20%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 20-25%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 25-30%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 30-35%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 35-40%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 40-45%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 45-50%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 50-55%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 55-60%.
The second flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 60-80%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 2-5%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 5-10%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 10-15%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 15-20%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 20-25%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 25-30%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 30-35%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 35-40%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 40-45%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 45-50%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 50-55%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 55-60%.
The second flow harmonic measured with the six-particle cumulats as a function of pseudorapidity in centrality bin 60-80%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 2-5%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 5-10%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 10-15%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 15-20%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 20-25%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 25-30%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 30-35%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 35-40%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 40-45%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 45-50%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 50-55%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 55-60%.
The second flow harmonic measured with the eight-particle cumulats as a function of pseudorapidity in centrality bin 60-80%.
The triangular flow harmonic measured with the two-particle cumulats as a function of pseudorapidity in centrality bin 0-60%.
The triangular flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 0-60%.
The triangular flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 0-60%.
The quadrangular flow harmonic measured with the two-particle cumulats as a function of pseudorapidity in centrality bin 0-25%.
The quadrangular flow harmonic measured with the Event Plane method as a function of pseudorapidity in centrality bin 0-25%.
The quadrangular flow harmonic measured with the four-particle cumulats as a function of pseudorapidity in centrality bin 0-25%.
The second flow harmonic measured with the two-particle cumulats as a function of <Npart>.
The second flow harmonic measured with the four-particle cumulats as a function of <Npart>.
The second flow harmonic measured with the six-particle cumulats as a function of <Npart>.
The second flow harmonic measured with the eight-particle cumulats as a function of <Npart>.
The ratio of second flow harmonics measured with the six- and four-particle cumulants as a function of <Npart>.
The ratio of second flow harmonics measured with the eight- and four-particle cumulants as a function of <Npart>.
The second flow harmonic measured with the Event Plane method as a function of <Npart>.
The triangular flow harmonic measured with the Event Plane method as a function of <Npart>.
The triangular flow harmonic measured with the two-particle cumulants as a function of <Npart>.
The triangular flow harmonic measured with the two-particle cumulants as a function of <Npart>.
The quadrangular flow harmonic measured with the Event Plane method as a function of <Npart>.
The quadrangular flow harmonic measured with the two-particle cumulants as a function of <Npart>.
The quadrangular flow harmonic measured with the two-particle cumulants as a function of <Npart>.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 2-5%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 5-10%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 10-15%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 15-20%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 20-25%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 25-30%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 30-35%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 35-40%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 40-45%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 45-50%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 50-55%.
The second flow harmonic fluctiuations, F(v2), as a function of transverse momentum in centrality bin 55-60%.
The second flow harmonic fluctuations, F(v2), as a function of <Npart>.
The triangular flow harmonic fluctuations, F(v3), as a function of <Npart>.
The triangular flow harmonic fluctuations, F(v4), as a function of <Npart>.
The second flow harmonic measured with the two-particle cumulats as a function of <Npart>.
The second flow harmonic measured with the four-particle cumulats as a function of <Npart>.
The second flow harmonic measured with the six-particle cumulats as a function of <Npart>.
The second flow harmonic measured with the eight-particle cumulats as a function of <Npart>.
The ratio of second flow harmonics measured with the six- and four-particle cumulants as a function of <Npart>.
The ratio of second flow harmonics measured with the eight- and four-particle cumulants as a function of <Npart>.
The triangular flow harmonic measured with the two-particle cumulants as a function of <Npart>.
The quadrangular flow harmonic measured with the Event Plane method as a function of <Npart>.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 2-5%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 5-10%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 10-15%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 15-20%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 20-25%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 25-30%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 30-35%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 35-40%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 40-45%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 45-50%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 50-55%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{EP} and v2{4}, as a function of transverse momentum in centrality bin 55-60%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 2-5%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 5-10%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 10-15%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 15-20%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 20-25%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 25-30%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 30-35%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 35-40%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 40-45%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 45-50%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 50-55%.
The second flow harmonic fluctiuations, F(v2), calculated from v2{2} and v2{4}, as a function of transverse momentum in centrality bin 55-60%.
The second flow harmonic fluctuations, F(v2), as a function of <Npart>.
The triangular flow harmonic fluctuations, F(v3), as a function of <Npart>.
The triangular flow harmonic fluctuations, F(v4), as a function of <Npart>.
When you search on a word, e.g. 'collisions', we will automatically search across everything we store about a record. But, sometimes you may wish to be more specific. Here we show you how.
Guidance and examples on the query string syntax can be found in the Elasticsearch documentation.
About HEPData Submitting to HEPData HEPData File Formats HEPData Coordinators HEPData Terms of Use HEPData Cookie Policy
Status Email Forum Twitter GitHub
Copyright ~1975-Present, HEPData | Powered by Invenio, funded by STFC, hosted and originally developed at CERN, supported and further developed at IPPP Durham.