Showing 10 of 249 results
A combination of measurements of the inclusive top-quark pair production cross-section performed by ATLAS and CMS in proton-proton collisions at centre-of-mass energies of 7 and 8 TeV at the LHC is presented. The cross-sections are obtained using top-quark pair decays with an opposite-charge electron-muon pair in the final state and with data corresponding to an integrated luminosity of about 5 fb$^{-1}$ at $\sqrt{s}=7$ TeV and about 20 fb$^{-1}$ at $\sqrt{s}=8$ TeV for each experiment. The combined cross-sections are determined to be $178.5 \pm 4.7$ pb at $\sqrt{s}=7$ TeV and $243.3^{+6.0}_{-5.9}$ pb at $\sqrt{s}=8$ TeV with a correlation of 0.41, using a reference top-quark mass value of 172.5 GeV. The ratio of the combined cross-sections is determined to be $R_{8/7}= 1.363\pm 0.032$. The combined measured cross-sections and their ratio agree well with theory calculations using several parton distribution function (PDF) sets. The values of the top-quark pole mass (with the strong coupling fixed at 0.118) and the strong coupling (with the top-quark pole mass fixed at 172.5 GeV) are extracted from the combined results by fitting a next-to-next-to-leading-order plus next-to-next-to-leading-log QCD prediction to the measurements. Using a version of the NNPDF3.1 PDF set containing no top-quark measurements, the results obtained are $m_t^\text{pole} = 173.4^{+1.8}_{-2.0}$ GeV and $\alpha_\text{s}(m_Z)= 0.1170^{+ 0.0021}_{-0.0018}$.
Full covariance matrix including all systematic uncertainties expressed as nuisance parameters. With the exception of the cross section parameters, all parameters were normalised to 1 before the fit. Therefore, the diagonal elements represent the constraint in quadrature.
Full covariance matrix including all systematic uncertainties expressed as nuisance parameters. With the exception of the cross section parameters, all parameters were normalised to 1 before the fit. Therefore, the diagonal elements represent the constraint in quadrature.
The first evidence for the Higgs boson decay to a $Z$ boson and a photon is presented, with a statistical significance of 3.4 standard deviations. The result is derived from a combined analysis of the searches performed by the ATLAS and CMS Collaborations with proton-proton collision data sets collected at the CERN Large Hadron Collider (LHC) from 2015 to 2018. These correspond to integrated luminosities of around 140 fb$^{-1}$ for each experiment, at a center-of-mass energy of 13 TeV. The measured signal yield is $2.2\pm0.7$ times the Standard Model prediction, and agrees with the theoretical expectation within 1.9 standard deviations.
The negative profile log-likelihood test statistic, where $\Lambda$ represents the likelihood ratio, as a function of the signal strength $\mu$ derived from the ATLAS data, the CMS data, and the combined result.
A search for quantum black holes in electron+jet and muon+jet invariant mass spectra is performed with 140 fb$^{-1}$ of data collected by the ATLAS detector in proton-proton collisions at $\sqrt{s}$ = 13 TeV at the Large Hadron Collider. The observed invariant mass spectrum of lepton+jet pairs is consistent with Standard Model expectations. Upper limits are set at 95% confidence level on the production cross-sections times branching fractions for quantum black holes decaying into a lepton and a quark in a search region with invariant mass above 2.0 TeV. The resulting quantum black hole lower mass threshold limit is 9.2 TeV in the Arkani-Hamed-Dimopoulos-Dvali model, and 6.8 TeV in the Randall-Sundrum model.
The 95% CL model-independent upper limits on $\sigma \times Br$ for the non-SM signal production with decay into the lepton+jet. The limits take into account statistical and systematic uncertainties. Circles along the solid red line indicate the lower border of the SR (threshold of SR, Th$_\mathrm{SR}$), above which the observed limit is computed. The expected limits are shown by the dashed line. The $\pm 1\sigma$ and $\pm 2\sigma$ bands of expected limits are shown in green and yellow, respectively. The limits are obtained with pseudo-experiments.
The combined 95% CL upper limits on $\sigma \times Br$ as a function of threshold mass, $M_\mathrm{th}$, for QBH production with decay into lepton+jet for ADD-model (extra dimensions n = 6). The limits take into account statistical and systematic uncertainties. Circles along the solid red line indicate the mass $M_\mathrm{th}$ of the signal where the observed limit is computed. The expected limits are shown by the dashed line. The $\pm 1\sigma$ and $\pm 2\sigma$ bands are shown in green and yellow, respectively. The theoretically predicted $\sigma \times Br$ for the QBH production and decay is shown as the solid blue curve with squares.
The combined 95% CL upper limits on $\sigma \times Br$ as a function of threshold mass, $M_\mathrm{th}$, for QBH production with decay into lepton+jet for RS1-model (extra dimensions n = 1). The limits take into account statistical and systematic uncertainties. Circles along the solid red line indicate the mass $M_\mathrm{th}$ of the signal where the observed limit is computed. The expected limits are shown by the dashed line. The $\pm 1\sigma$ and $\pm 2\sigma$ bands are shown in green and yellow, respectively. The theoretically predicted $\sigma \times Br$ for the QBH production and decay is shown as the solid blue curve with squares.
Electroweak symmetry breaking explains the origin of the masses of elementary particles through their interactions with the Higgs field. Besides the measurements of the Higgs boson properties, the study of the scattering of massive vector bosons with spin one allows the nature of electroweak symmetry breaking to be probed. Among all processes related to vector-boson scattering, the electroweak production of two jets and a $Z$-boson pair is a rare and important one. Here we report the observation of this process from proton-proton collision data corresponding to an integrated luminosity of 139/fb recorded at a centre-of-mass energy of 13 TeV with the ATLAS detector at the Large Hadron Collider. We consider two different final states originating from the decays of the $Z$-boson pair - one containing four charged leptons and the other containing two charged leptons and two neutrinos. The hypothesis of no electroweak production is rejected with a statistical significance of 5.7 $\sigma$, and the measured cross-section for electroweak production is consistent with the standard model prediction. In addition, we report cross-sections for inclusive production of a $Z$-boson pair and two jets for the two final states.
Measured and predicted fiducial cross-sections in both the lllljj and ll$\nu\nu$jj channels for the inclusive ZZjj processes. Uncertainties due to different sources are presented
Signal strength and significance of EW ZZjj processes
Signal strength and significance of EW ZZjj processes
Measured and predicted fiducial cross-sections in both the lllljj and ll$\nu\nu$jj channels for the inclusive ZZjj processes. Uncertainties due to different sources are presented.
Measured and predicted fiducial cross-sections in both the lllljj and ll$\nu\nu$jj channels for the inclusive ZZjj processes. Uncertainties due to different sources are presented.
Observed and expected multivariate discriminant distribution in the $\ell\ell\ell\ell jj$ QCD CR.
Observed and expected multivariate discriminant distribution in the $\ell\ell\ell\ell jj$ QCD CR.
Observed and expected multivariate discriminant distribution in the $\ell\ell\ell\ell jj$ SR.
Observed and expected multivariate discriminant distribution in the $\ell\ell\ell\ell jj$ SR.
Observed and expected multivariate discriminant distribution in the $\ell\ell\nu\nu jj$ SR.
Observed and expected multivariate discriminant distribution in the $\ell\ell\nu\nu jj$ SR.
A measurement of the top-quark mass ($m_t$) in the $t\bar{t}\rightarrow~\textrm{lepton}+\textrm{jets}$ channel is presented, with an experimental technique which exploits semileptonic decays of $b$-hadrons produced in the top-quark decay chain. The distribution of the invariant mass $m_{\ell\mu}$ of the lepton, $\ell$ (with $\ell=e,\mu$), from the $W$-boson decay and the muon, $\mu$, originating from the $b$-hadron decay is reconstructed, and a binned-template profile likelihood fit is performed to extract $m_t$. The measurement is based on data corresponding to an integrated luminosity of 36.1 fb$^{-1}$ of $\sqrt{s} = 13~\textrm{TeV}$$pp$ collisions provided by the Large Hadron Collider and recorded by the ATLAS detector. The measured value of the top-quark mass is $m_{t} = 174.41\pm0.39~(\textrm{stat.})\pm0.66~(\textrm{syst.})\pm0.25~(\textrm{recoil})~\textrm{GeV}$, where the third uncertainty arises from changing the PYTHIA8 parton shower gluon-recoil scheme, used in top-quark decays, to a recently developed setup.
Top mass measurement result.
List of all the individual sources of systematic uncertainty considered in the analysis. The individual sources, each corresponding to an independent nuisance parameter in the fit, are grouped into categories, as indicated in the first column. The second column shows the impact of each of the individual sources on the measurement, obtained as the shift on the top mass induced by a positive shift of the each of the nuisance parameters by its post-fit uncertainty. Sources for which no impact is indicated are neglected in the fit procedure as their impact on the total prediction is negligible in any of the bins. The last column shows the statistical uncertainty in each of the reported numbers as estimated with the bootstrap method.
Ranking, from top to bottom, of the main systematic uncertainties (excluding recoil) showing the pulls and the impact of the systematic uncertainties on the top mass, from the combined opposite sign (OS) and same sign (SS) binned-template profile likelihood fit to data. The OS or SS refers to the charge signs of the primary lepton and the soft muon. The gamma parameters are NPs used to describe the effect of the limited statistics of the sample.
Correlation matrix for the individual sources of systematic uncertainty considered in the analysis, for the combined opposite sign (OS) and same sign (SS) binned-template profile likelihood fit to data. The OS or SS refers to the charge signs of the primary lepton and the soft muon. The gamma parameters are NPs used to describe the effect of the limited statistics of the samples.
The $t\bar{t}$ production cross-section is measured in the lepton+jets channel using proton$-$proton collision data at a centre-of-mass energy of $\sqrt{s}=13$ TeV collected with the ATLAS detector at the LHC. The dataset corresponds to an integrated luminosity of 139 fb$^{-1}$. Events with exactly one charged lepton and four or more jets in the final state, with at least one jet containing $b$-hadrons, are used to determine the $t\bar{t}$ production cross-section through a profile-likelihood fit. The inclusive cross-section is measured to be ${\sigma_{\text{inc}} = 830 \pm 0.4~ \text{(stat.)}\pm 36~\text{(syst.)}\pm 14~\text{(lumi.)}~\mathrm{pb}}$ with a relative uncertainty of 4.6 %. The result is consistent with theoretical calculations at next-to-next-to-leading order in perturbative QCD. The fiducial $t\bar{t}$ cross-section within the experimental acceptance is also measured.
The results of fitted inclusive and fiducial ${t\bar{t}}$ cross-sections
The results of fitted inclusive and fiducial ${t\bar{t}}$ cross-sections
Ranking of the systematic uncertainties on the measured cross-section, normalised to the predicted value, in the inclusive fit to data. The impact of each nuisance parameter, $\Delta \sigma_{\text{inc}}/\sigma^{\text{pred.}}_{\text{inc}}$, is computed by comparing the nominal best-fit value of $\sigma_{\text{inc}}/\sigma^{\text{pred}}_{\text{inc}}$ with the result of the fit when fixing the considered nuisance parameter to its best-fit value, $\theta$, shifted by its pre-fit (post-fit) uncertainties $\pm \Delta \theta$ ($\pm \Delta \hat{\theta}$). The figure shows the effect of the ten most significant uncertainties.
Ranking of the systematic uncertainties on the measured cross-section, normalised to the predicted value, in the inclusive fit to data. The impact of each nuisance parameter, $\Delta \sigma_{\text{inc}}/\sigma^{\text{pred.}}_{\text{inc}}$, is computed by comparing the nominal best-fit value of $\sigma_{\text{inc}}/\sigma^{\text{pred}}_{\text{inc}}$ with the result of the fit when fixing the considered nuisance parameter to its best-fit value, $\theta$, shifted by its pre-fit (post-fit) uncertainties $\pm \Delta \theta$ ($\pm \Delta \hat{\theta}$). The figure shows the effect of the ten most significant uncertainties.
Ranking of the systematic uncertainties on the measured cross-section, normalised to the predicted value, in the fiducial fit to data. The impact of each nuisance parameter, $\Delta \sigma_{\text{fid}}/\sigma^{\text{pred.}}_{\text{fid}}$, is computed by comparing the nominal best-fit value of $\sigma_{\text{fid}}/\sigma^{\text{pred}}_{\text{fid}}$ with the result of the fit when fixing the considered nuisance parameter to its best-fit value, $\theta$, shifted by its pre-fit (post-fit) uncertainties $\pm \Delta \theta$ ($\pm \Delta \hat{\theta}$). The figure shows the effect of the ten most significant uncertainties.
Ranking of the systematic uncertainties on the measured cross-section, normalised to the predicted value, in the fiducial fit to data. The impact of each nuisance parameter, $\Delta \sigma_{\text{fid}}/\sigma^{\text{pred.}}_{\text{fid}}$, is computed by comparing the nominal best-fit value of $\sigma_{\text{fid}}/\sigma^{\text{pred}}_{\text{fid}}$ with the result of the fit when fixing the considered nuisance parameter to its best-fit value, $\theta$, shifted by its pre-fit (post-fit) uncertainties $\pm \Delta \theta$ ($\pm \Delta \hat{\theta}$). The figure shows the effect of the ten most significant uncertainties.
Impact of different categories of systematic uncertainties on the fiducial and inclusive measurements. The quoted values are obtained by repeating the fit, fixing a set of nuisance parameters of the sources corresponding to the considered category, and subtracting in quadrature the resulting uncertainty from the total uncertainty of the nominal fit. The total uncertainty is different from the sum in quadrature of the different components due to correlations between nuisance parameters built by the fit.
Impact of different categories of systematic uncertainties on the fiducial and inclusive measurements. The quoted values are obtained by repeating the fit, fixing a set of nuisance parameters of the sources corresponding to the considered category, and subtracting in quadrature the resulting uncertainty from the total uncertainty of the nominal fit. The total uncertainty is different from the sum in quadrature of the different components due to correlations between nuisance parameters built by the fit.
Fiducial region definition
Fiducial region definition
The Standard Model of particle physics encapsulates our current best understanding of physics at the smallest scales. A fundamental axiom of this theory is the universality of the couplings of the different generations of leptons to the electroweak gauge bosons. The measurement of the ratio of the rate of decay of $W$ bosons to $\tau$-leptons and muons, $R(\tau/\mu) = B(W \to \tau \nu_\tau)/B(W \to \mu \nu_\mu)$, constitutes an important test of this axiom. A measurement of this quantity with a novel technique using di-leptonic $t\bar{t}$ events is presented based on 139 fb${}^{-1}$ of data recorded with the ATLAS detector in proton--proton collisions at $\sqrt{s}=13$ TeV. Muons originating from $W$ bosons and those originating from an intermediate $\tau$-lepton are distinguished using the lifetime of the $\tau$-lepton, through the muon transverse impact parameter, and differences in the muon transverse momentum spectra. The value of $R(\tau/\mu)$ is found to be $0.992 \pm 0.013 [\pm 0.007 (stat) \pm 0.011 (syst)]$ and is in agreement with the hypothesis of universal lepton couplings as postulated in the Standard Model. This is the most precise measurement of this ratio, and the only such measurement from the Large Hadron Collider, to date.
The number of data and fitted simulated events in each bin of the $|d_{0}^{\mu}|$ distribution in the $5<p_{\textrm{T}}^{\mu}<10$ GeV selection in the $e-\mu$ channel.
The number of data and fitted simulated events in each bin of the $|d_{0}^{\mu}|$ distribution in the $5<p_{\textrm{T}}^{\mu}<10$ GeV selection in the $\mu-\mu$ channel.
The number of data and fitted simulated events in each bin of the $|d_{0}^{\mu}|$ distribution in the $10<p_{\textrm{T}}^{\mu}<20$ GeV selection in the $e-\mu$ channel.
The number of data and fitted simulated events in each bin of the $|d_{0}^{\mu}|$ distribution in the $10<p_{\textrm{T}}^{\mu}<20$ GeV selection in the $\mu-\mu$ channel.
The number of data and fitted simulated events in each bin of the $|d_{0}^{\mu}|$ distribution in the $20<p_{\textrm{T}}^{\mu}<250$ GeV selection in the $e-\mu$ channel.
The number of data and fitted simulated events in each bin of the $|d_{0}^{\mu}|$ distribution in the $20<p_{\textrm{T}}^{\mu}<250$ GeV selection in the $\mu-\mu$ channel.
The measurement of the ratio of the rate of decay of W bosons to τ-leptons and muons, $R(\tau/\mu)=B(W\rightarrow\tau\nu_\tau)/B(W\rightarrow \mu\nu_\mu)$.
A search for dark-matter particles in events with large missing transverse momentum and a Higgs boson candidate decaying into two photons is reported. The search uses $139$ fb$^{-1}$ of proton-proton collision data collected at $\sqrt{s}=13$ TeV with the ATLAS detector at the CERN LHC between 2015 and 2018. No significant excess of events over the Standard Model predictions is observed. The results are interpreted by extracting limits on three simplified models that include either vector or pseudoscalar mediators and predict a final state with a pair of dark-matter candidates and a Higgs boson decaying into two photons.
The $E^{miss}_{T}$ distribution of data and MC after the diphoton selection.
The observed exclusion contor for the $Z^{\prime}_{B}$ model in the $m_{\chi}$-$m_{Z^{\prime}_{B}}$ plane.
The expected exclusion contor for the $Z^{\prime}_{B}$ model in the $m_{\chi}$-$m_{Z^{\prime}_{B}}$ plane.
The +1 $\sigma$ band of the observed exclusion contor for the $Z^{\prime}_{B}$ model in the $m_{\chi}$-$m_{Z^{\prime}_{B}}$ plane.
The -1 $\sigma$ band of the observed exclusion contor for the $Z^{\prime}_{B}$ model in the $m_{\chi}$-$m_{Z^{\prime}_{B}}$ plane.
A comparison of the inferred limits to the constraints from direct detection experiments on the spin-independent DM--nucleon cross section in the context of the $Z'_B$ simplified model with vector couplings. Limits are shown at 90% CL.
The observed exclusion contor for the $Z^{\prime}$-2HDM model in the $m_{A}$-$m_{Z^{\prime}}$ plane.
The expected exclusion contor for the $Z^{\prime}$-2HDM model in the $m_{A}$-$m_{Z^{\prime}}$ plane.
The +1 $\sigma$ band of the observed exclusion contor for the $m_{A}$-$Z^{\prime}$-2HDM model in the $m_{Z^{\prime}}$ plane.
The -1 $\sigma$ band of the observed exclusion contor for the $m_{A}$-$Z^{\prime}$-2HDM model in the $m_{Z^{\prime}}$ plane.
The observed exclusion contor for the 2HDM-a model in the $m_{A}$-$m_{a}$ plane.
The expected exclusion contor for the 2HDM-a model in the $m_{A}$-$m_{a}$ plane.
The +1 $\sigma$ band of the observed exclusion contor for the 2HDM-a model in the $m_{A}$-$m_{a}$ plane.
The -1 $\sigma$ band of the observed exclusion contor for the 2HDM-a model in the $m_{A}$-$m_{a}$ plane.
The observed exclusion contor for the 2HDM-a model in the $tan\beta$-$m_{a}$ plane.
The expected exclusion contor for the 2HDM-a model in the $tan\beta$-$m_{a}$ plane.
The +1 $\sigma$ band of the observed exclusion contor for the 2HDM-a model in the $tan\beta$-$m_{a}$ plane.
The -1 $\sigma$ band of the observed exclusion contor for the 2HDM-a model in the $tan\beta$-$m_{a}$ plane.
The exclusion limits at 95% CL for the 2HDM+a model as a function of $\sin \theta$ for $m_{A,H^{\pm},H}$= 600GeV, $m_a$ = 200GeV, $\tan \beta$ = 1.0$.
The exclusion limits at 95% CL for the 2HDM+a model as a function of $\sin \theta$ for $m_{A,H^{\pm},H}$= 1000GeV, $m_a$ = 350GeV, $\tan \beta$ = 1.0$.
Breakdown of the dominant systematic uncertainties.
Event yields in the range of 120 $<m_{\gamma\gamma}<$ 130 GeV for data, signal models, the SM Higgs boson background and non-resonant background in each analysis category, for an integrated luminosity of $139$fb$^{-1}$.
Detailed background contributions from the SM Higgs boson and continuum background for each cut
Detailed contributions from the signals for each cut.
Acceptance times efficiency for several signals in each category.
This paper presents studies of Bose-Einstein correlations (BEC) in proton-proton collisions at a centre-of-mass energy of 13 TeV, using data from the ATLAS detector at the CERN Large Hadron Collider. Data were collected in a special low-luminosity configuration with a minimum-bias trigger and a high-multiplicity track trigger, accumulating integrated luminosities of 151 $\mu$b$^{-1}$ and 8.4 nb$^{-1}$ respectively. The BEC are measured for pairs of like-sign charged particles, each with $|\eta|$ < 2.5, for two kinematic ranges: the first with particle $p_T$ > 100 MeV and the second with particle $p_T$ > 500 MeV. The BEC parameters, characterizing the source radius and particle correlation strength, are investigated as functions of charged-particle multiplicity (up to 300) and average transverse momentum of the pair (up to 1.5 GeV). The double-differential dependence on charged-particle multiplicity and average transverse momentum of the pair is also studied. The BEC radius is found to be independent of the charged-particle multiplicity for high charged-particle multiplicity (above 100), confirming a previous observation at lower energy. This saturation occurs independent of the transverse momentum of the pair.
Comparison of single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q) and C<sub>2</sub><sup>MC</sup>(Q), with the two-particle double-ratio correlation function, R<sub>2</sub>(Q), for the high-multiplicity track (HMT) events using the opposite hemisphere (OHP) like-charge particles pairs reference sample for k<sub>T</sub> - interval 1000 < k<sub>T</sub> ≤ 1500 MeV.
Comparison of single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q) and C<sub>2</sub><sup>MC</sup>(Q), with the two-particle double-ratio correlation function, R<sub>2</sub>(Q), for the high-multiplicity track (HMT) events using the unlike-charge particle (UCP) pairs reference sample for k<sub>T</sub> - interval 1000 < k<sub>T</sub> ≤ 1500 MeV.
The Bose-Einstein correlation (BEC) parameter R as a function of n<sub>ch</sub> for MB events using different MC generators in the calculation of R<sub>2</sub>(Q). The uncertainties shown are statistical. The lower panel of each plot shows the ratio of the BEC parameters obtained using EPOS LHC (red circles), Pythia 8 Monash (blue squares) and Herwig++ UE-EE-5 (green triangles) compared with the parameters obtained using Pythia 8 A2. The gray band in the lower panels is the MC systematic uncertainty, obtained as explained in the text.
The Bose-Einstein correlation (BEC) parameter R as a function of n<sub>ch</sub> for HMT events using different MC generators in the calculation of R<sub>2</sub>(Q). The uncertainties shown are statistical. The lower panel of each plot shows the ratio of the BEC parameters obtained using EPOS LHC (red circles), Pythia 8 Monash (blue squares) and Herwig++ UE-EE-5 (green triangles) compared with the parameters obtained using Pythia 8 A2. The gray band in the lower panels is the MC systematic uncertainty, obtained as explained in the text.
The Bose-Einstein correlation (BEC) parameter R as a function of k<sub>T</sub> for MB events using different MC generators in the calculation of R<sub>2</sub>(Q). The uncertainties shown are statistical. The lower panel of each plot shows the ratio of the BEC parameters obtained using EPOS LHC (red circles), Pythia 8 Monash (blue squares) and Herwig++ UE-EE-5 (green triangles) compared with the parameters obtained using Pythia 8 A2. The gray band in the lower panels is the MC systematic uncertainty, obtained as explained in the text.
The Bose-Einstein correlation (BEC) parameter λ as a function of k<sub>T</sub> for MB events using different MC generators in the calculation of R<sub>2</sub>(Q). The uncertainties shown are statistical. The lower panel of each plot shows the ratio of the BEC parameters obtained using EPOS LHC (red circles), Pythia 8 Monash (blue squares) and Herwig++ UE-EE-5 (green triangles) compared with the parameters obtained using Pythia 8 A2. The gray band in the lower panels is the MC systematic uncertainty, obtained as explained in the text.
The two-particle double-ratio correlation function, R<sub>2</sub>(Q), for pp collisions for track p<sub>T</sub> >100 MeV at √s=13 TeV in the multiplicity interval 71 ≤ n<sub>ch</sub> < 80 for the minimum-bias (MB) events. The blue dashed and red solid lines show the results of the exponential and Gaussian fits, respectively. The region excluded from the fits is shown. The statistical uncertainty and the systematic uncertainty for imperfections in the data reconstruction procedure are added in quadrature.
The two-particle double-ratio correlation function, R<sub>2</sub>(Q), for pp collisions for track p<sub>T</sub> >100 MeV at √s=13 TeV in the multiplicity interval 231 ≤ n<sub>ch</sub> < 300 for the high-multiplicity track (HMT) events. The blue dashed and red solid lines show the results of the exponential and Gaussian fits, respectively. The region excluded from the fits is shown. The statistical uncertainty and the systematic uncertainty for imperfections in the data reconstruction procedure are added in quadrature.
The dependence of the correlation strength, λ(m<sub>ch</sub>), on rescaled multiplicity, m<sub>ch</sub>, obtained from the exponential fit of the R<sub>2</sub>(Q) correlation functions for tracks with p<sub>T</sub> > 100 MeV and p<sub>T</sub> > 500 MeV at √s = 13 TeV for the minimum-bias (MB) and high multiplicity track (HMT) data. The uncertainties represent the sum in quadrature of the statistical and asymmetric systematic contributions. The black and blue solid curves represent the exponential fit of λ(m<sub>ch</sub>) for p<sub>T</sub> >100 MeV and p<sub>T</sub> >500 MeV, respectively.
The dependence of the correlation strength, λ(m<sub>ch</sub>), on rescaled multiplicity, m<sub>ch</sub>, obtained from the exponential fit of the R<sub>2</sub>(Q) correlation functions for tracks with p<sub>T</sub> > 100 MeV and p<sub>T</sub> > 500 MeV at √s = 13 TeV for the minimum-bias (MB) and high multiplicity track (HMT) data. The uncertainties represent the sum in quadrature of the statistical and asymmetric systematic contributions. The black and blue solid curves represent the exponential fit of λ(m<sub>ch</sub>) for p<sub>T</sub> >100 MeV and p<sub>T</sub> >500 MeV, respectively.
The dependence of the correlation strength, λ(m<sub>ch</sub>), on rescaled multiplicity, m<sub>ch</sub>, obtained from the exponential fit of the R<sub>2</sub>(Q) correlation functions for tracks with p<sub>T</sub> > 100 MeV and p<sub>T</sub> > 500 MeV at √s = 13 TeV for the minimum-bias (MB) and high multiplicity track (HMT) data. The uncertainties represent the sum in quadrature of the statistical and asymmetric systematic contributions. The black and blue solid curves represent the exponential fit of λ(m<sub>ch</sub>) for p<sub>T</sub> >100 MeV and p<sub>T</sub> >500 MeV, respectively.
The dependence of the correlation strength, λ(m<sub>ch</sub>), on rescaled multiplicity, m<sub>ch</sub>, obtained from the exponential fit of the R<sub>2</sub>(Q) correlation functions for tracks with p<sub>T</sub> > 100 MeV and p<sub>T</sub> > 500 MeV at √s = 13 TeV for the minimum-bias (MB) and high multiplicity track (HMT) data. The uncertainties represent the sum in quadrature of the statistical and asymmetric systematic contributions. The black and blue solid curves represent the exponential fit of λ(m<sub>ch</sub>) for p<sub>T</sub> >100 MeV and p<sub>T</sub> >500 MeV, respectively.
The dependence of the source radius, R(m<sub>ch</sub>), on m<sub>ch</sub>. The uncertainties represent the sum in quadrature of the statistical and asymmetric systematic contributions. The black and blue solid curves represent the fit of R(m<sub>ch</sub>) for ∛m<sub>ch</sub> < 1.2 for p<sub>T</sub> >100 MeV and p<sub>T</sub> >500 MeV, respectively. The black and blue dotted curves are extensions of the black and blue solid curves beyond ∛m<sub>ch</sub> > 1.2, respectively. The black and brown dashed curves represent the saturation value of R(m<sub>ch</sub>) for ∛m<sub>ch</sub> > 1.45 with p<sub>T</sub> >100 MeV and for ∛m<sub>ch</sub> > 1.6 with p<sub>T</sub> >500 MeV, respectively.
The dependence of the source radius, R(m<sub>ch</sub>), on m<sub>ch</sub>. The uncertainties represent the sum in quadrature of the statistical and asymmetric systematic contributions. The black and blue solid curves represent the fit of R(m<sub>ch</sub>) for ∛m<sub>ch</sub> < 1.2 for p<sub>T</sub> >100 MeV and p<sub>T</sub> >500 MeV, respectively. The black and blue dotted curves are extensions of the black and blue solid curves beyond ∛m<sub>ch</sub> > 1.2, respectively. The black and brown dashed curves represent the saturation value of R(m<sub>ch</sub>) for ∛m<sub>ch</sub> > 1.45 with p<sub>T</sub> >100 MeV and for ∛m<sub>ch</sub> > 1.6 with p<sub>T</sub> >500 MeV, respectively.
The dependence of the source radius, R(m<sub>ch</sub>), on m<sub>ch</sub>. The uncertainties represent the sum in quadrature of the statistical and asymmetric systematic contributions. The black and blue solid curves represent the fit of R(m<sub>ch</sub>) for ∛m<sub>ch</sub> < 1.2 for p<sub>T</sub> >100 MeV and p<sub>T</sub> >500 MeV, respectively. The black and blue dotted curves are extensions of the black and blue solid curves beyond ∛m<sub>ch</sub> > 1.2, respectively. The black and brown dashed curves represent the saturation value of R(m<sub>ch</sub>) for ∛m<sub>ch</sub> > 1.45 with p<sub>T</sub> >100 MeV and for ∛m<sub>ch</sub> > 1.6 with p<sub>T</sub> >500 MeV, respectively.
The dependence of the source radius, R(m<sub>ch</sub>), on m<sub>ch</sub>. The uncertainties represent the sum in quadrature of the statistical and asymmetric systematic contributions. The black and blue solid curves represent the fit of R(m<sub>ch</sub>) for ∛m<sub>ch</sub> < 1.2 for p<sub>T</sub> >100 MeV and p<sub>T</sub> >500 MeV, respectively. The black and blue dotted curves are extensions of the black and blue solid curves beyond ∛m<sub>ch</sub> > 1.2, respectively. The black and brown dashed curves represent the saturation value of R(m<sub>ch</sub>) for ∛m<sub>ch</sub> > 1.45 with p<sub>T</sub> >100 MeV and for ∛m<sub>ch</sub> > 1.6 with p<sub>T</sub> >500 MeV, respectively.
The dependence of the R(m<sub>ch</sub>) on ∛m<sub>ch</sub>. The uncertainties represent the sum in quadrature of the statistical and asymmetric systematic contributions. The black and blue solid curves represent the fit of R(m<sub>ch</sub>) for ∛m<sub>ch</sub> < 1.2 for p<sub>T</sub> >100 MeV and p<sub>T</sub> >500 MeV, respectively. The black and blue dotted curves are extensions of the black and blue solid curves beyond ∛m<sub>ch</sub> > 1.2, respectively. The black and brown dashed curves represent the saturation value of R(m<sub>ch</sub>) for ∛m<sub>ch</sub> > 1.45 with p<sub>T</sub> >100 MeV and for ∛m<sub>ch</sub> > 1.6 with p<sub>T</sub> >500 MeV, respectively
The dependence of the R(m<sub>ch</sub>) on ∛m<sub>ch</sub>. The uncertainties represent the sum in quadrature of the statistical and asymmetric systematic contributions. The black and blue solid curves represent the fit of R(m<sub>ch</sub>) for ∛m<sub>ch</sub> < 1.2 for p<sub>T</sub> >100 MeV and p<sub>T</sub> >500 MeV, respectively. The black and blue dotted curves are extensions of the black and blue solid curves beyond ∛m<sub>ch</sub> > 1.2, respectively. The black and brown dashed curves represent the saturation value of R(m<sub>ch</sub>) for ∛m<sub>ch</sub> > 1.45 with p<sub>T</sub> >100 MeV and for ∛m<sub>ch</sub> > 1.6 with p<sub>T</sub> >500 MeV, respectively
The dependence of the R(m<sub>ch</sub>) on ∛m<sub>ch</sub>. The uncertainties represent the sum in quadrature of the statistical and asymmetric systematic contributions. The black and blue solid curves represent the fit of R(m<sub>ch</sub>) for ∛m<sub>ch</sub> < 1.2 for p<sub>T</sub> >100 MeV and p<sub>T</sub> >500 MeV, respectively. The black and blue dotted curves are extensions of the black and blue solid curves beyond ∛m<sub>ch</sub> > 1.2, respectively. The black and brown dashed curves represent the saturation value of R(m<sub>ch</sub>) for ∛m<sub>ch</sub> > 1.45 with p<sub>T</sub> >100 MeV and for ∛m<sub>ch</sub> > 1.6 with p<sub>T</sub> >500 MeV, respectively
The dependence of the R(m<sub>ch</sub>) on ∛m<sub>ch</sub>. The uncertainties represent the sum in quadrature of the statistical and asymmetric systematic contributions. The black and blue solid curves represent the fit of R(m<sub>ch</sub>) for ∛m<sub>ch</sub> < 1.2 for p<sub>T</sub> >100 MeV and p<sub>T</sub> >500 MeV, respectively. The black and blue dotted curves are extensions of the black and blue solid curves beyond ∛m<sub>ch</sub> > 1.2, respectively. The black and brown dashed curves represent the saturation value of R(m<sub>ch</sub>) for ∛m<sub>ch</sub> > 1.45 with p<sub>T</sub> >100 MeV and for ∛m<sub>ch</sub> > 1.6 with p<sub>T</sub> >500 MeV, respectively
Comparison of single-ratio two-particle correlation functions, using the unlike-charge particle (UCP) pair reference sample, for minimum-bias (MB) events, showing C<sub>2</sub><sup>data</sup>(Q) (top panel) at 13 TeV (black circles) and 7 TeV (open blue circles), and the ratio of C<sub>2</sub><sup>7 TeV</sup> (Q) to C<sub>2</sub><sup>13 TeV</sup> (Q) (bottom panel). Comparison of C<sub>2</sub><sup>data</sup> (Q) for representative multiplicity region 3.09 < m<sub>ch</sub> ≤ 3.86. The statistical and systematic uncertainties, combined in quadrature, are presented. The systematic uncertainties include track efficiency, Coulomb correction, non-closure and multiplicity-unfolding uncertainties.
Comparison of single-ratio two-particle correlation functions, using the unlike-charge particle (UCP) pair reference sample, for minimum-bias (MB) events, showing C<sub>2</sub><sup>data</sup>(Q) (top panel) at 13 TeV (black circles) and 7 TeV (open blue circles), and the ratio of C<sub>2</sub><sup>7 TeV</sup> (Q) to C<sub>2</sub><sup>13 TeV</sup> (Q) (bottom panel). Comparison of C<sub>2</sub><sup>data</sup> (Q) for representative k<sub>T</sub> region 400 < k<sub>T</sub> ≤500 MeV. The statistical and systematic uncertainties, combined in quadrature, are presented. The systematic uncertainties include track efficiency, Coulomb correction, non-closure and multiplicity-unfolding uncertainties.
The k<sub>T</sub> dependence of the correlation strength, λ(k<sub>T</sub>), obtained from the exponential fit to the R<sub>2</sub>(Q) correlation functions for events with multiplicity n<sub>ch</sub> ≥ 2 and transfer momentum of tracks with p<sub>T</sub> >100 MeV and p<sub>T</sub> >500 MeV at √s=13 TeV for the minimum-bias (MB) and high-multiplicity track (HMT) events. The uncertainties represent the sum in quadrature of the statistical and systematic contributions. The curves represent the exponential fits to λ(k<sub>T</sub>).
The k<sub>T</sub> dependence of the correlation strength, λ(k<sub>T</sub>), obtained from the exponential fit to the R<sub>2</sub>(Q) correlation functions for events with multiplicity n<sub>ch</sub> ≥ 2 and transfer momentum of tracks with p<sub>T</sub> >100 MeV and p<sub>T</sub> >500 MeV at √s=13 TeV for the minimum-bias (MB) and high-multiplicity track (HMT) events. The uncertainties represent the sum in quadrature of the statistical and systematic contributions. The curves represent the exponential fits to λ(k<sub>T</sub>).
The k<sub>T</sub> dependence of the correlation strength, λ(k<sub>T</sub>), obtained from the exponential fit to the R<sub>2</sub>(Q) correlation functions for events with multiplicity n<sub>ch</sub> ≥ 2 and transfer momentum of tracks with p<sub>T</sub> >100 MeV and p<sub>T</sub> >500 MeV at √s=13 TeV for the minimum-bias (MB) and high-multiplicity track (HMT) events. The uncertainties represent the sum in quadrature of the statistical and systematic contributions. The curves represent the exponential fits to λ(k<sub>T</sub>).
The k<sub>T</sub> dependence of the correlation strength, λ(k<sub>T</sub>), obtained from the exponential fit to the R<sub>2</sub>(Q) correlation functions for events with multiplicity n<sub>ch</sub> ≥ 2 and transfer momentum of tracks with p<sub>T</sub> >100 MeV and p<sub>T</sub> >500 MeV at √s=13 TeV for the minimum-bias (MB) and high-multiplicity track (HMT) events. The uncertainties represent the sum in quadrature of the statistical and systematic contributions. The curves represent the exponential fits to λ(k<sub>T</sub>).
The k<sub>T</sub> dependence of the source radius, R(k<sub>T</sub>), obtained from the exponential fit to the R<sub>2</sub>(Q) correlation functions for events with multiplicity n<sub>ch</sub> ≥ 2 and transfer momentum of tracks with p<sub>T</sub> >100 MeV and p<sub>T</sub> >500 MeV at √s=13 TeV for the minimum-bias (MB) and high-multiplicity track (HMT) events. The uncertainties represent the sum in quadrature of the statistical and systematic contributions. The curves represent the exponential fits to R(k<sub>T</sub>).
The k<sub>T</sub> dependence of the source radius, R(k<sub>T</sub>), obtained from the exponential fit to the R<sub>2</sub>(Q) correlation functions for events with multiplicity n<sub>ch</sub> ≥ 2 and transfer momentum of tracks with p<sub>T</sub> >100 MeV and p<sub>T</sub> >500 MeV at √s=13 TeV for the minimum-bias (MB) and high-multiplicity track (HMT) events. The uncertainties represent the sum in quadrature of the statistical and systematic contributions. The curves represent the exponential fits to R(k<sub>T</sub>).
The k<sub>T</sub> dependence of the source radius, R(k<sub>T</sub>), obtained from the exponential fit to the R<sub>2</sub>(Q) correlation functions for events with multiplicity n<sub>ch</sub> ≥ 2 and transfer momentum of tracks with p<sub>T</sub> >100 MeV and p<sub>T</sub> >500 MeV at √s=13 TeV for the minimum-bias (MB) and high-multiplicity track (HMT) events. The uncertainties represent the sum in quadrature of the statistical and systematic contributions. The curves represent the exponential fits to R(k<sub>T</sub>).
The k<sub>T</sub> dependence of the source radius, R(k<sub>T</sub>), obtained from the exponential fit to the R<sub>2</sub>(Q) correlation functions for events with multiplicity n<sub>ch</sub> ≥ 2 and transfer momentum of tracks with p<sub>T</sub> >100 MeV and p<sub>T</sub> >500 MeV at √s=13 TeV for the minimum-bias (MB) and high-multiplicity track (HMT) events. The uncertainties represent the sum in quadrature of the statistical and systematic contributions. The curves represent the exponential fits to R(k<sub>T</sub>).
The two-dimensional dependence on m<sub>ch</sub> and k<sub>T</sub> for p<sub>T</sub> > 100 MeV for the correlation strength, λ, obtained from the exponential fit to the R<sub>2</sub>(Q) correlation functions using the MB sample for m<sub>ch</sub> ≤ 3.08 and the HMT sample for m<sub>ch</sub> > 3.08.
The two-dimensional dependence on m<sub>ch</sub> and k<sub>T</sub> for p<sub>T</sub> > 100 MeV for the source radius, R, obtained from the exponential fit to the R<sub>2</sub>(Q) correlation functions using the MB sample for m<sub>ch</sub> ≤ 3.08 and the HMT sample for m<sub>ch</sub> > 3.08.
The parameter λ for p<sub>T</sub> > 100 MeV as a function of k<sub>T</sub> in selected low m<sub>ch</sub> intervals. The error bars and boxes represent the statistical and systematic contributions, respectively.
The parameter λ for p<sub>T</sub> > 100 MeV as a function of k<sub>T</sub> in selected low m<sub>ch</sub> intervals. The error bars and boxes represent the statistical and systematic contributions, respectively.
The parameter λ for p<sub>T</sub> > 100 MeV as a function of k<sub>T</sub> in selected high m<sub>ch</sub> intervals. The error bars and boxes represent the statistical and systematic contributions, respectively.
The parameter λ for p<sub>T</sub> > 100 MeV as a function of k<sub>T</sub> in selected high m<sub>ch</sub> intervals. The error bars and boxes represent the statistical and systematic contributions, respectively.
The parameter λ for p<sub>T</sub> > 100 MeV as a function of m<sub>ch</sub> in k<sub>T</sub> intervals between 0.1 and 0.5 GeV. The error bars and boxes represent the statistical and systematic contributions, respectively.
The parameter λ for p<sub>T</sub> > 100 MeV as a function of m<sub>ch</sub> in k<sub>T</sub> intervals between 0.1 and 0.5 GeV. The error bars and boxes represent the statistical and systematic contributions, respectively.
The parameter λ for p<sub>T</sub> > 100 MeV as a function of m<sub>ch</sub> in k<sub>T</sub> intervals between 0.5 and 1.5 GeV. The error bars and boxes represent the statistical and systematic contributions, respectively.
The parameter λ for p<sub>T</sub> > 100 MeV as a function of m<sub>ch</sub> in k<sub>T</sub> intervals between 0.5 and 1.5 GeV. The error bars and boxes represent the statistical and systematic contributions, respectively.
The parameter R for p<sub>T</sub> > 100 MeV as a function of k<sub>T</sub> in selected low m<sub>ch</sub> intervals. The error bars and boxes represent the statistical and systematic contributions, respectively.
The parameter R for p<sub>T</sub> > 100 MeV as a function of k<sub>T</sub> in selected low m<sub>ch</sub> intervals. The error bars and boxes represent the statistical and systematic contributions, respectively.
The parameter R for p<sub>T</sub> > 100 MeV as a function of k<sub>T</sub> in selected high m<sub>ch</sub> intervals. The error bars and boxes represent the statistical and systematic contributions, respectively.
The parameter R for p<sub>T</sub> > 100 MeV as a function of k<sub>T</sub> in selected high m<sub>ch</sub> intervals. The error bars and boxes represent the statistical and systematic contributions, respectively.
The parameter R for p<sub>T</sub> > 100 MeV as a function of m<sub>ch</sub> in k<sub>T</sub> intervals between 0.1 and 0.5 GeV. The error bars and boxes represent the statistical and systematic contributions, respectively.
The parameter R for p<sub>T</sub> > 100 MeV as a function of m<sub>ch</sub> in k<sub>T</sub> intervals between 0.1 and 0.5 GeV. The error bars and boxes represent the statistical and systematic contributions, respectively.
The parameter R for p<sub>T</sub> > 100 MeV as a function of m<sub>ch</sub> in k<sub>T</sub> intervals between 0.5 and 1.5 GeV. The error bars and boxes represent the statistical and systematic contributions, respectively.
The parameter R for p<sub>T</sub> > 100 MeV as a function of m<sub>ch</sub> in k<sub>T</sub> intervals between 0.5 and 1.5 GeV. The error bars and boxes represent the statistical and systematic contributions, respectively.
The fit parameter μ describing the dependence of the correlation strength, λ, on charged-particle scaled multiplicity, for track p<sub>T</sub>>100 MeV and track p<sub>T</sub>>500 MeV in the minimum-bias (MB) and high-multiplicity track (HMT) samples at √s = 13 TeV. The error bars and boxes represent the statistical and systematic contributions, respectively. The black solid (blue dashed) curve represents the exponential fit of the dependence of parameter μ on m<sub>ch</sub> for tracks with p<sub>T</sub> >100 MeV (p<sub>T</sub> >500 MeV).
The fit parameter μ describing the dependence of the correlation strength, λ, on charged-particle scaled multiplicity, for track p<sub>T</sub>>100 MeV and track p<sub>T</sub>>500 MeV in the minimum-bias (MB) and high-multiplicity track (HMT) samples at √s = 13 TeV. The error bars and boxes represent the statistical and systematic contributions, respectively. The black solid (blue dashed) curve represents the exponential fit of the dependence of parameter μ on m<sub>ch</sub> for tracks with p<sub>T</sub> >100 MeV (p<sub>T</sub> >500 MeV).
The fit parameter μ describing the dependence of the correlation strength, λ, on charged-particle scaled multiplicity, for track p<sub>T</sub>>100 MeV and track p<sub>T</sub>>500 MeV in the minimum-bias (MB) and high-multiplicity track (HMT) samples at √s = 13 TeV. The error bars and boxes represent the statistical and systematic contributions, respectively. The black solid (blue dashed) curve represents the exponential fit of the dependence of parameter μ on m<sub>ch</sub> for tracks with p<sub>T</sub> >100 MeV (p<sub>T</sub> >500 MeV).
The fit parameter μ describing the dependence of the correlation strength, λ, on charged-particle scaled multiplicity, for track p<sub>T</sub>>100 MeV and track p<sub>T</sub>>500 MeV in the minimum-bias (MB) and high-multiplicity track (HMT) samples at √s = 13 TeV. The error bars and boxes represent the statistical and systematic contributions, respectively. The black solid (blue dashed) curve represents the exponential fit of the dependence of parameter μ on m<sub>ch</sub> for tracks with p<sub>T</sub> >100 MeV (p<sub>T</sub> >500 MeV).
The fit parameter ν describing the dependence of the correlation strength, λ, on charged-particle scaled multiplicity, for track p<sub>T</sub>>100 MeV and track p<sub>T</sub>>500 MeV in the minimum-bias (MB) and high-multiplicity track (HMT) samples at √s = 13 TeV. The error bars and boxes represent the statistical and systematic contributions, respectively. The black solid (blue dashed) curve represents the exponential fit of the dependence of parameter ν on m<sub>ch</sub> for tracks with p<sub>T</sub> >100 MeV (p<sub>T</sub> >500 MeV).
The fit parameter ν describing the dependence of the correlation strength, λ, on charged-particle scaled multiplicity, for track p<sub>T</sub>>100 MeV and track p<sub>T</sub>>500 MeV in the minimum-bias (MB) and high-multiplicity track (HMT) samples at √s = 13 TeV. The error bars and boxes represent the statistical and systematic contributions, respectively. The black solid (blue dashed) curve represents the exponential fit of the dependence of parameter ν on m<sub>ch</sub> for tracks with p<sub>T</sub> >100 MeV (p<sub>T</sub> >500 MeV).
The fit parameter ν describing the dependence of the correlation strength, λ, on charged-particle scaled multiplicity, for track p<sub>T</sub>>100 MeV and track p<sub>T</sub>>500 MeV in the minimum-bias (MB) and high-multiplicity track (HMT) samples at √s = 13 TeV. The error bars and boxes represent the statistical and systematic contributions, respectively. The black solid (blue dashed) curve represents the exponential fit of the dependence of parameter ν on m<sub>ch</sub> for tracks with p<sub>T</sub> >100 MeV (p<sub>T</sub> >500 MeV).
The fit parameter ν describing the dependence of the correlation strength, λ, on charged-particle scaled multiplicity, for track p<sub>T</sub>>100 MeV and track p<sub>T</sub>>500 MeV in the minimum-bias (MB) and high-multiplicity track (HMT) samples at √s = 13 TeV. The error bars and boxes represent the statistical and systematic contributions, respectively. The black solid (blue dashed) curve represents the exponential fit of the dependence of parameter ν on m<sub>ch</sub> for tracks with p<sub>T</sub> >100 MeV (p<sub>T</sub> >500 MeV).
The parameter ξ describing the dependence of the source radius, R, on charged-particle scaled multiplicity, m<sub>ch</sub>, for track p<sub>T</sub>>100 MeV and track p<sub>T</sub>>500 MeV in the minimum-bias (MB) and high-multiplicity track (HMT) samples at √s = 13 TeV. The error bars and boxes represent the statistical and systematic contributions, respectively. The black solid and blue dashed curves represent the saturated value of the parameter ξ for m<sub>ch</sub> > 3.0 for tracks with p<sub>T</sub> >100 MeV and for m<sub>ch</sub> > 2.8 for tracks with p<sub>T</sub> >500 MeV, respectively.
The parameter ξ describing the dependence of the source radius, R, on charged-particle scaled multiplicity, m<sub>ch</sub>, for track p<sub>T</sub>>100 MeV and track p<sub>T</sub>>500 MeV in the minimum-bias (MB) and high-multiplicity track (HMT) samples at √s = 13 TeV. The error bars and boxes represent the statistical and systematic contributions, respectively. The black solid and blue dashed curves represent the saturated value of the parameter ξ for m<sub>ch</sub> > 3.0 for tracks with p<sub>T</sub> >100 MeV and for m<sub>ch</sub> > 2.8 for tracks with p<sub>T</sub> >500 MeV, respectively.
The parameter ξ describing the dependence of the source radius, R, on charged-particle scaled multiplicity, m<sub>ch</sub>, for track p<sub>T</sub>>100 MeV and track p<sub>T</sub>>500 MeV in the minimum-bias (MB) and high-multiplicity track (HMT) samples at √s = 13 TeV. The error bars and boxes represent the statistical and systematic contributions, respectively. The black solid and blue dashed curves represent the saturated value of the parameter ξ for m<sub>ch</sub> > 3.0 for tracks with p<sub>T</sub> >100 MeV and for m<sub>ch</sub> > 2.8 for tracks with p<sub>T</sub> >500 MeV, respectively.
The parameter ξ describing the dependence of the source radius, R, on charged-particle scaled multiplicity, m<sub>ch</sub>, for track p<sub>T</sub>>100 MeV and track p<sub>T</sub>>500 MeV in the minimum-bias (MB) and high-multiplicity track (HMT) samples at √s = 13 TeV. The error bars and boxes represent the statistical and systematic contributions, respectively. The black solid and blue dashed curves represent the saturated value of the parameter ξ for m<sub>ch</sub> > 3.0 for tracks with p<sub>T</sub> >100 MeV and for m<sub>ch</sub> > 2.8 for tracks with p<sub>T</sub> >500 MeV, respectively.
The parameter κ describing the dependence of the source radius, R, on charged-particle scaled multiplicity, m<sub>ch</sub>, for track p<sub>T</sub>>100 MeV and track p<sub>T</sub>>500 MeV in the minimum-bias (MB) and high-multiplicity track (HMT) samples at √s = 13 TeV. The error bars and boxes represent the statistical and systematic contributions, respectively. The black solid and blue dashed curves represent the exponential fit to the parameter κ for tracks with p<sub>T</sub> >100 MeV and for tracks with p<sub>T</sub> >500 MeV, respectively.
The parameter κ describing the dependence of the source radius, R, on charged-particle scaled multiplicity, m<sub>ch</sub>, for track p<sub>T</sub>>100 MeV and track p<sub>T</sub>>500 MeV in the minimum-bias (MB) and high-multiplicity track (HMT) samples at √s = 13 TeV. The error bars and boxes represent the statistical and systematic contributions, respectively. The black solid and blue dashed curves represent the exponential fit to the parameter κ for tracks with p<sub>T</sub> >100 MeV and for tracks with p<sub>T</sub> >500 MeV, respectively.
The parameter κ describing the dependence of the source radius, R, on charged-particle scaled multiplicity, m<sub>ch</sub>, for track p<sub>T</sub>>100 MeV and track p<sub>T</sub>>500 MeV in the minimum-bias (MB) and high-multiplicity track (HMT) samples at √s = 13 TeV. The error bars and boxes represent the statistical and systematic contributions, respectively. The black solid and blue dashed curves represent the exponential fit to the parameter κ for tracks with p<sub>T</sub> >100 MeV and for tracks with p<sub>T</sub> >500 MeV, respectively.
The parameter κ describing the dependence of the source radius, R, on charged-particle scaled multiplicity, m<sub>ch</sub>, for track p<sub>T</sub>>100 MeV and track p<sub>T</sub>>500 MeV in the minimum-bias (MB) and high-multiplicity track (HMT) samples at √s = 13 TeV. The error bars and boxes represent the statistical and systematic contributions, respectively. The black solid and blue dashed curves represent the exponential fit to the parameter κ for tracks with p<sub>T</sub> >100 MeV and for tracks with p<sub>T</sub> >500 MeV, respectively.
The two-dimensional dependence on m<sub>ch</sub> and k<sub>T</sub> for p<sub>T</sub> > 500 MeV for the correlation strength, λ, obtained from the exponential fit to the R<sub>2</sub>(Q) correlation functions using the MB sample for m<sub>ch</sub> ≤ 3.08 and the HMT sample for m<sub>ch</sub> > 3.08.
The two-dimensional dependence on m<sub>ch</sub> and k<sub>T</sub> for p<sub>T</sub> > 500 MeV for the source radius, R, obtained from the exponential fit to the R<sub>2</sub>(Q) correlation functions using the MB sample for m<sub>ch</sub> ≤ 3.08 and the HMT sample for m<sub>ch</sub> > 3.08.
The parameter λ for p<sub>T</sub> > 500 MeV as a function of k<sub>T</sub> in selected low m<sub>ch</sub> intervals. The error bars and boxes represent the statistical and systematic contributions, respectively.
The parameter λ for p<sub>T</sub> > 500 MeV as a function of k<sub>T</sub> in selected low m<sub>ch</sub> intervals. The error bars and boxes represent the statistical and systematic contributions, respectively.
The parameter λ for p<sub>T</sub> > 500 MeV as a function of k<sub>T</sub> in selected high m<sub>ch</sub> intervals. The error bars and boxes represent the statistical and systematic contributions, respectively.
The parameter λ for p<sub>T</sub> > 500 MeV as a function of k<sub>T</sub> in selected high m<sub>ch</sub> intervals. The error bars and boxes represent the statistical and systematic contributions, respectively.
The parameter λ for p<sub>T</sub> > 500 MeV as a function of m<sub>ch</sub> in k<sub>T</sub> intervals between 0.5 and 1.5 GeV. The error bars and boxes represent the statistical and systematic contributions, respectively.
The parameter λ for p<sub>T</sub> > 500 MeV as a function of m<sub>ch</sub> in k<sub>T</sub> intervals between 0.5 and 1.5 GeV. The error bars and boxes represent the statistical and systematic contributions, respectively.
The parameter R for p<sub>T</sub> > 500 MeV as a function of k<sub>T</sub> in selected low m<sub>ch</sub> intervals. The error bars and boxes represent the statistical and systematic contributions, respectively.
The parameter R for p<sub>T</sub> > 500 MeV as a function of k<sub>T</sub> in selected low m<sub>ch</sub> intervals. The error bars and boxes represent the statistical and systematic contributions, respectively.
The parameter R for p<sub>T</sub> > 500 MeV as a function of k<sub>T</sub> in selected high m<sub>ch</sub> intervals. The error bars and boxes represent the statistical and systematic contributions, respectively.
The parameter R for p<sub>T</sub> > 500 MeV as a function of k<sub>T</sub> in selected high m<sub>ch</sub> intervals. The error bars and boxes represent the statistical and systematic contributions, respectively.
The parameter R for p<sub>T</sub> > 500 MeV as a function of m<sub>ch</sub> in k<sub>T</sub> intervals between 0.5 and 1.5 GeV. The error bars and boxes represent the statistical and systematic contributions, respectively.
The parameter R for p<sub>T</sub> > 500 MeV as a function of m<sub>ch</sub> in k<sub>T</sub> intervals between 0.5 and 1.5 GeV. The error bars and boxes represent the statistical and systematic contributions, respectively.
ATLAS and CMS results for the source radius R as a function of n<sub>ch</sub> in pp interactions at 13 TeV. The CMS results (open circles) have been adjusted (by the CMS collaboration) to the ATLAS kinematic region∶ p<sub>T</sub> > 100 MeV and |η|<2.5. The ATLAS uncertainties are the sum in quadrature of the statistical and asymmetric systematic uncertainties. For CMS, only the systematic uncertainties are shown since the statistical uncertainties are smaller than the marker size. The dashed blue (ATLAS) and black (CMS) lines represent the fit to ∛n<sub>ch</sub> at low multiplicity, continued as dotted lines beyond the fit range. The solid green (ATLAS) and broken black (CMS) lines indicate the plateau level at high multiplicity.
ATLAS and CMS results for the source radius R as a function of n<sub>ch</sub> in pp interactions at 13 TeV. The CMS results (open circles) have been adjusted (by the CMS collaboration) to the ATLAS kinematic region∶ p<sub>T</sub> > 100 MeV and |η|<2.5. The ATLAS uncertainties are the sum in quadrature of the statistical and asymmetric systematic uncertainties. For CMS, only the systematic uncertainties are shown since the statistical uncertainties are smaller than the marker size. The dashed blue (ATLAS) and black (CMS) lines represent the fit to ∛n<sub>ch</sub> at low multiplicity, continued as dotted lines beyond the fit range. The solid green (ATLAS) and broken black (CMS) lines indicate the plateau level at high multiplicity.
ATLAS and CMS results for the source radius R as a function of n<sub>ch</sub> in pp interactions at 13 TeV. The CMS results (open circles) have been adjusted (by the CMS collaboration) to the ATLAS kinematic region∶ p<sub>T</sub> > 100 MeV and |η|<2.5. The ATLAS uncertainties are the sum in quadrature of the statistical and asymmetric systematic uncertainties. For CMS, only the systematic uncertainties are shown since the statistical uncertainties are smaller than the marker size. The dashed blue (ATLAS) and black (CMS) lines represent the fit to ∛n<sub>ch</sub> at low multiplicity, continued as dotted lines beyond the fit range. The solid green (ATLAS) and broken black (CMS) lines indicate the plateau level at high multiplicity.
ATLAS and CMS results for the source radius R as a function of ∛n<sub>ch</sub> in pp interactions at 13 TeV. The CMS results (open circles) have been adjusted (by the CMS collaboration) to the ATLAS kinematic region∶ p<sub>T</sub> > 100 MeV and |η|<2.5. The ATLAS uncertainties are the sum in quadrature of the statistical and asymmetric systematic uncertainties. For CMS, only the systematic uncertainties are shown since the statistical uncertainties are smaller than the marker size. The dashed blue (ATLAS) and black (CMS) lines represent the fit to ∛n<sub>ch</sub> at low multiplicity, continued as dotted lines beyond the fit range. The solid green (ATLAS) and broken black (CMS) lines indicate the plateau level at high multiplicity.
ATLAS and CMS results for the source radius R as a function of ∛n<sub>ch</sub> in pp interactions at 13 TeV. The CMS results (open circles) have been adjusted (by the CMS collaboration) to the ATLAS kinematic region∶ p<sub>T</sub> > 100 MeV and |η|<2.5. The ATLAS uncertainties are the sum in quadrature of the statistical and asymmetric systematic uncertainties. For CMS, only the systematic uncertainties are shown since the statistical uncertainties are smaller than the marker size. The dashed blue (ATLAS) and black (CMS) lines represent the fit to ∛n<sub>ch</sub> at low multiplicity, continued as dotted lines beyond the fit range. The solid green (ATLAS) and broken black (CMS) lines indicate the plateau level at high multiplicity.
ATLAS and CMS results for the source radius R as a function of ∛n<sub>ch</sub> in pp interactions at 13 TeV. The CMS results (open circles) have been adjusted (by the CMS collaboration) to the ATLAS kinematic region∶ p<sub>T</sub> > 100 MeV and |η|<2.5. The ATLAS uncertainties are the sum in quadrature of the statistical and asymmetric systematic uncertainties. For CMS, only the systematic uncertainties are shown since the statistical uncertainties are smaller than the marker size. The dashed blue (ATLAS) and black (CMS) lines represent the fit to ∛n<sub>ch</sub> at low multiplicity, continued as dotted lines beyond the fit range. The solid green (ATLAS) and broken black (CMS) lines indicate the plateau level at high multiplicity.
Systematic uncertainties (in percent) in the correlation strength, λ, and source radius, R, for the exponential fit of the two-particle double-ratio correlation functions, R<sub>2</sub>(Q), for p<sub>T</sub> > 100 MeV at √s= 13 TeV for the MB and HMT events. The choice of MC generator gives rise to asymmetric uncertainties, denoted by uparrow and downarrow. This asymmetry propagates through to the cumulative uncertainty. The columns under ‘Uncertainty range’ show the range of systematic uncertainty from the fits in the various n<sub>ch</sub> intervals.
The results of the fits to the dependencies of the correlation strength, λ, and source radius, R, on the average rescaled charged-particle multiplicity, m<sub>ch</sub>, for |η| < 2.5 and both p<sub>T</sub> > 100 MeV and p<sub>T</sub> > 500 MeV at √s = 13 TeV for the minimum-bias (MB) and the high-multiplicity track (HMT) events. The parameters γ and δ resulting from a joint fit to the MB and HMT data are presented. The total uncertainties are shown.
The results of the fits to the dependencies of the correlation strength, λ, and source radius, R, on the pair average transverse momentum, k<sub>T</sub>, for various functional forms and for minimum-bias (MB) and high-multiplicity track (HMT) events for p<sub>T</sub> > 100 MeV and p<sub>T</sub> > 500 MeV at √s = 13 TeV. The total uncertainties are shown.
The Bose-Einstein correlation (BEC) parameters λ and R as a function of n<sub>ch</sub> and k<sub>T</sub> using different MC generators in the calculation of R<sub>2</sub>(Q). (a) λ versus n<sub>ch</sub> for MB events, (b) λ versus n<sub>ch</sub> for HMT events, (c) λ versus k<sub>T</sub> and (d) R versus k<sub>T</sub> for MB events. The uncertainties shown are statistical. The lower panel of each plot shows the ratio of the BEC parameters obtained using EPOS LHC (red circles), Pythia 8 Monash (blue squares) and Herwig++ UE-EE-5 (green triangles) compared with the parameters obtained using Pythia 8 A2. The gray band in the lower panels is the MC systematic uncertainty, obtained as explained in the text.
The Bose-Einstein correlation (BEC) parameters λ and R as a function of n<sub>ch</sub> and k<sub>T</sub> using different MC generators in the calculation of R<sub>2</sub>(Q). (a) λ versus n<sub>ch</sub> for MB events, (b) λ versus n<sub>ch</sub> for HMT events, (c) λ versus k<sub>T</sub> and (d) R versus k<sub>T</sub> for MB events. The uncertainties shown are statistical. The lower panel of each plot shows the ratio of the BEC parameters obtained using EPOS LHC (red circles), Pythia 8 Monash (blue squares) and Herwig++ UE-EE-5 (green triangles) compared with the parameters obtained using Pythia 8 A2. The gray band in the lower panels is the MC systematic uncertainty, obtained as explained in the text.
The Bose-Einstein correlation (BEC) parameters λ and R as a function of n<sub>ch</sub> and k<sub>T</sub> using different MC generators in the calculation of R<sub>2</sub>(Q). (a) λ versus n<sub>ch</sub> for MB events, (b) λ versus n<sub>ch</sub> for HMT events, (c) λ versus k<sub>T</sub> and (d) R versus k<sub>T</sub> for MB events. The uncertainties shown are statistical. The lower panel of each plot shows the ratio of the BEC parameters obtained using EPOS LHC (red circles), Pythia 8 Monash (blue squares) and Herwig++ UE-EE-5 (green triangles) compared with the parameters obtained using Pythia 8 A2. The gray band in the lower panels is the MC systematic uncertainty, obtained as explained in the text.
The Bose-Einstein correlation (BEC) parameters λ and R as a function of n<sub>ch</sub> and k<sub>T</sub> using different MC generators in the calculation of R<sub>2</sub>(Q). (a) λ versus n<sub>ch</sub> for MB events, (b) λ versus n<sub>ch</sub> for HMT events, (c) λ versus k<sub>T</sub> and (d) R versus k<sub>T</sub> for MB events. The uncertainties shown are statistical. The lower panel of each plot shows the ratio of the BEC parameters obtained using EPOS LHC (red circles), Pythia 8 Monash (blue squares) and Herwig++ UE-EE-5 (green triangles) compared with the parameters obtained using Pythia 8 A2. The gray band in the lower panels is the MC systematic uncertainty, obtained as explained in the text.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 2 < n<sub>ch</sub> ≤ 10, (b) 11 < n<sub>ch</sub> ≤ 20, (c) 21 < n<sub>ch</sub> ≤ 30, (d) 31 < n<sub>ch</sub> ≤ 40, (e) 41 < n<sub>ch</sub> ≤ 50, (f) 51 < n<sub>ch</sub> ≤ 60, (g) 61 < n<sub>ch</sub> ≤ 70, (h) 71 < n<sub>ch</sub> ≤ 80 and (i) 81 < n<sub>ch</sub> ≤ 90. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 2 < n<sub>ch</sub> ≤ 10, (b) 11 < n<sub>ch</sub> ≤ 20, (c) 21 < n<sub>ch</sub> ≤ 30, (d) 31 < n<sub>ch</sub> ≤ 40, (e) 41 < n<sub>ch</sub> ≤ 50, (f) 51 < n<sub>ch</sub> ≤ 60, (g) 61 < n<sub>ch</sub> ≤ 70, (h) 71 < n<sub>ch</sub> ≤ 80 and (i) 81 < n<sub>ch</sub> ≤ 90. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 2 < n<sub>ch</sub> ≤ 10, (b) 11 < n<sub>ch</sub> ≤ 20, (c) 21 < n<sub>ch</sub> ≤ 30, (d) 31 < n<sub>ch</sub> ≤ 40, (e) 41 < n<sub>ch</sub> ≤ 50, (f) 51 < n<sub>ch</sub> ≤ 60, (g) 61 < n<sub>ch</sub> ≤ 70, (h) 71 < n<sub>ch</sub> ≤ 80 and (i) 81 < n<sub>ch</sub> ≤ 90. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 2 < n<sub>ch</sub> ≤ 10, (b) 11 < n<sub>ch</sub> ≤ 20, (c) 21 < n<sub>ch</sub> ≤ 30, (d) 31 < n<sub>ch</sub> ≤ 40, (e) 41 < n<sub>ch</sub> ≤ 50, (f) 51 < n<sub>ch</sub> ≤ 60, (g) 61 < n<sub>ch</sub> ≤ 70, (h) 71 < n<sub>ch</sub> ≤ 80 and (i) 81 < n<sub>ch</sub> ≤ 90. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 2 < n<sub>ch</sub> ≤ 10, (b) 11 < n<sub>ch</sub> ≤ 20, (c) 21 < n<sub>ch</sub> ≤ 30, (d) 31 < n<sub>ch</sub> ≤ 40, (e) 41 < n<sub>ch</sub> ≤ 50, (f) 51 < n<sub>ch</sub> ≤ 60, (g) 61 < n<sub>ch</sub> ≤ 70, (h) 71 < n<sub>ch</sub> ≤ 80 and (i) 81 < n<sub>ch</sub> ≤ 90. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 2 < n<sub>ch</sub> ≤ 10, (b) 11 < n<sub>ch</sub> ≤ 20, (c) 21 < n<sub>ch</sub> ≤ 30, (d) 31 < n<sub>ch</sub> ≤ 40, (e) 41 < n<sub>ch</sub> ≤ 50, (f) 51 < n<sub>ch</sub> ≤ 60, (g) 61 < n<sub>ch</sub> ≤ 70, (h) 71 < n<sub>ch</sub> ≤ 80 and (i) 81 < n<sub>ch</sub> ≤ 90. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 2 < n<sub>ch</sub> ≤ 10, (b) 11 < n<sub>ch</sub> ≤ 20, (c) 21 < n<sub>ch</sub> ≤ 30, (d) 31 < n<sub>ch</sub> ≤ 40, (e) 41 < n<sub>ch</sub> ≤ 50, (f) 51 < n<sub>ch</sub> ≤ 60, (g) 61 < n<sub>ch</sub> ≤ 70, (h) 71 < n<sub>ch</sub> ≤ 80 and (i) 81 < n<sub>ch</sub> ≤ 90. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 2 < n<sub>ch</sub> ≤ 10, (b) 11 < n<sub>ch</sub> ≤ 20, (c) 21 < n<sub>ch</sub> ≤ 30, (d) 31 < n<sub>ch</sub> ≤ 40, (e) 41 < n<sub>ch</sub> ≤ 50, (f) 51 < n<sub>ch</sub> ≤ 60, (g) 61 < n<sub>ch</sub> ≤ 70, (h) 71 < n<sub>ch</sub> ≤ 80 and (i) 81 < n<sub>ch</sub> ≤ 90. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 2 < n<sub>ch</sub> ≤ 10, (b) 11 < n<sub>ch</sub> ≤ 20, (c) 21 < n<sub>ch</sub> ≤ 30, (d) 31 < n<sub>ch</sub> ≤ 40, (e) 41 < n<sub>ch</sub> ≤ 50, (f) 51 < n<sub>ch</sub> ≤ 60, (g) 61 < n<sub>ch</sub> ≤ 70, (h) 71 < n<sub>ch</sub> ≤ 80 and (i) 81 < n<sub>ch</sub> ≤ 90. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 91 < n<sub>ch</sub> ≤ 100, (b) 101 < n<sub>ch</sub> ≤ 125, (c) 126 < n<sub>ch</sub> ≤ 150, (d) 151 < n<sub>ch</sub> ≤ 200, (e) 201 < n<sub>ch</sub> ≤ 250. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 91 < n<sub>ch</sub> ≤ 100, (b) 101 < n<sub>ch</sub> ≤ 125, (c) 126 < n<sub>ch</sub> ≤ 150, (d) 151 < n<sub>ch</sub> ≤ 200, (e) 201 < n<sub>ch</sub> ≤ 250. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 91 < n<sub>ch</sub> ≤ 100, (b) 101 < n<sub>ch</sub> ≤ 125, (c) 126 < n<sub>ch</sub> ≤ 150, (d) 151 < n<sub>ch</sub> ≤ 200, (e) 201 < n<sub>ch</sub> ≤ 250. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 91 < n<sub>ch</sub> ≤ 100, (b) 101 < n<sub>ch</sub> ≤ 125, (c) 126 < n<sub>ch</sub> ≤ 150, (d) 151 < n<sub>ch</sub> ≤ 200, (e) 201 < n<sub>ch</sub> ≤ 250. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 91 < n<sub>ch</sub> ≤ 100, (b) 101 < n<sub>ch</sub> ≤ 125, (c) 126 < n<sub>ch</sub> ≤ 150, (d) 151 < n<sub>ch</sub> ≤ 200, (e) 201 < n<sub>ch</sub> ≤ 250. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the high-multiplicity track (HMT) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 101 < n<sub>ch</sub> ≤ 110, (b) 111 < n<sub>ch</sub> ≤ 120, (c) 121 < n<sub>ch</sub> ≤ 130, (d) 131 < n<sub>ch</sub> ≤ 140, (e) 141 < n<sub>ch</sub> ≤ 155, (f) 156 < n<sub>ch</sub> ≤ 175, (g) 176 < n<sub>ch</sub> ≤ 200, (h) 201 < n<sub>ch</sub> ≤ 230 and (i) 231 < n<sub>ch</sub> ≤ 300. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the high-multiplicity track (HMT) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 101 < n<sub>ch</sub> ≤ 110, (b) 111 < n<sub>ch</sub> ≤ 120, (c) 121 < n<sub>ch</sub> ≤ 130, (d) 131 < n<sub>ch</sub> ≤ 140, (e) 141 < n<sub>ch</sub> ≤ 155, (f) 156 < n<sub>ch</sub> ≤ 175, (g) 176 < n<sub>ch</sub> ≤ 200, (h) 201 < n<sub>ch</sub> ≤ 230 and (i) 231 < n<sub>ch</sub> ≤ 300. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the high-multiplicity track (HMT) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 101 < n<sub>ch</sub> ≤ 110, (b) 111 < n<sub>ch</sub> ≤ 120, (c) 121 < n<sub>ch</sub> ≤ 130, (d) 131 < n<sub>ch</sub> ≤ 140, (e) 141 < n<sub>ch</sub> ≤ 155, (f) 156 < n<sub>ch</sub> ≤ 175, (g) 176 < n<sub>ch</sub> ≤ 200, (h) 201 < n<sub>ch</sub> ≤ 230 and (i) 231 < n<sub>ch</sub> ≤ 300. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the high-multiplicity track (HMT) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 101 < n<sub>ch</sub> ≤ 110, (b) 111 < n<sub>ch</sub> ≤ 120, (c) 121 < n<sub>ch</sub> ≤ 130, (d) 131 < n<sub>ch</sub> ≤ 140, (e) 141 < n<sub>ch</sub> ≤ 155, (f) 156 < n<sub>ch</sub> ≤ 175, (g) 176 < n<sub>ch</sub> ≤ 200, (h) 201 < n<sub>ch</sub> ≤ 230 and (i) 231 < n<sub>ch</sub> ≤ 300. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the high-multiplicity track (HMT) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 101 < n<sub>ch</sub> ≤ 110, (b) 111 < n<sub>ch</sub> ≤ 120, (c) 121 < n<sub>ch</sub> ≤ 130, (d) 131 < n<sub>ch</sub> ≤ 140, (e) 141 < n<sub>ch</sub> ≤ 155, (f) 156 < n<sub>ch</sub> ≤ 175, (g) 176 < n<sub>ch</sub> ≤ 200, (h) 201 < n<sub>ch</sub> ≤ 230 and (i) 231 < n<sub>ch</sub> ≤ 300. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the high-multiplicity track (HMT) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 101 < n<sub>ch</sub> ≤ 110, (b) 111 < n<sub>ch</sub> ≤ 120, (c) 121 < n<sub>ch</sub> ≤ 130, (d) 131 < n<sub>ch</sub> ≤ 140, (e) 141 < n<sub>ch</sub> ≤ 155, (f) 156 < n<sub>ch</sub> ≤ 175, (g) 176 < n<sub>ch</sub> ≤ 200, (h) 201 < n<sub>ch</sub> ≤ 230 and (i) 231 < n<sub>ch</sub> ≤ 300. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the high-multiplicity track (HMT) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 101 < n<sub>ch</sub> ≤ 110, (b) 111 < n<sub>ch</sub> ≤ 120, (c) 121 < n<sub>ch</sub> ≤ 130, (d) 131 < n<sub>ch</sub> ≤ 140, (e) 141 < n<sub>ch</sub> ≤ 155, (f) 156 < n<sub>ch</sub> ≤ 175, (g) 176 < n<sub>ch</sub> ≤ 200, (h) 201 < n<sub>ch</sub> ≤ 230 and (i) 231 < n<sub>ch</sub> ≤ 300. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the high-multiplicity track (HMT) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 101 < n<sub>ch</sub> ≤ 110, (b) 111 < n<sub>ch</sub> ≤ 120, (c) 121 < n<sub>ch</sub> ≤ 130, (d) 131 < n<sub>ch</sub> ≤ 140, (e) 141 < n<sub>ch</sub> ≤ 155, (f) 156 < n<sub>ch</sub> ≤ 175, (g) 176 < n<sub>ch</sub> ≤ 200, (h) 201 < n<sub>ch</sub> ≤ 230 and (i) 231 < n<sub>ch</sub> ≤ 300. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the high-multiplicity track (HMT) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 101 < n<sub>ch</sub> ≤ 110, (b) 111 < n<sub>ch</sub> ≤ 120, (c) 121 < n<sub>ch</sub> ≤ 130, (d) 131 < n<sub>ch</sub> ≤ 140, (e) 141 < n<sub>ch</sub> ≤ 155, (f) 156 < n<sub>ch</sub> ≤ 175, (g) 176 < n<sub>ch</sub> ≤ 200, (h) 201 < n<sub>ch</sub> ≤ 230 and (i) 231 < n<sub>ch</sub> ≤ 300. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample k<sub>T</sub> - intervals∶ (a) 100 < k<sub>T</sub> ≤ 200 MeV, (b) 200 < k<sub>T</sub> ≤ 300 MeV, (c) 300 < k<sub>T</sub> ≤ 400 MeV, (d) 400 < k<sub>T</sub> ≤ 500 MeV, (e) 500 < k<sub>T</sub> ≤ 600 MeV, (f) 600 < k<sub>T</sub> ≤ 700 MeV, (g) 700 < k<sub>T</sub> ≤ 1000 MeV, and (h) 1000 < k<sub>T</sub> ≤ 1500 MeV. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample k<sub>T</sub> - intervals∶ (a) 100 < k<sub>T</sub> ≤ 200 MeV, (b) 200 < k<sub>T</sub> ≤ 300 MeV, (c) 300 < k<sub>T</sub> ≤ 400 MeV, (d) 400 < k<sub>T</sub> ≤ 500 MeV, (e) 500 < k<sub>T</sub> ≤ 600 MeV, (f) 600 < k<sub>T</sub> ≤ 700 MeV, (g) 700 < k<sub>T</sub> ≤ 1000 MeV, and (h) 1000 < k<sub>T</sub> ≤ 1500 MeV. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample k<sub>T</sub> - intervals∶ (a) 100 < k<sub>T</sub> ≤ 200 MeV, (b) 200 < k<sub>T</sub> ≤ 300 MeV, (c) 300 < k<sub>T</sub> ≤ 400 MeV, (d) 400 < k<sub>T</sub> ≤ 500 MeV, (e) 500 < k<sub>T</sub> ≤ 600 MeV, (f) 600 < k<sub>T</sub> ≤ 700 MeV, (g) 700 < k<sub>T</sub> ≤ 1000 MeV, and (h) 1000 < k<sub>T</sub> ≤ 1500 MeV. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample k<sub>T</sub> - intervals∶ (a) 100 < k<sub>T</sub> ≤ 200 MeV, (b) 200 < k<sub>T</sub> ≤ 300 MeV, (c) 300 < k<sub>T</sub> ≤ 400 MeV, (d) 400 < k<sub>T</sub> ≤ 500 MeV, (e) 500 < k<sub>T</sub> ≤ 600 MeV, (f) 600 < k<sub>T</sub> ≤ 700 MeV, (g) 700 < k<sub>T</sub> ≤ 1000 MeV, and (h) 1000 < k<sub>T</sub> ≤ 1500 MeV. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample k<sub>T</sub> - intervals∶ (a) 100 < k<sub>T</sub> ≤ 200 MeV, (b) 200 < k<sub>T</sub> ≤ 300 MeV, (c) 300 < k<sub>T</sub> ≤ 400 MeV, (d) 400 < k<sub>T</sub> ≤ 500 MeV, (e) 500 < k<sub>T</sub> ≤ 600 MeV, (f) 600 < k<sub>T</sub> ≤ 700 MeV, (g) 700 < k<sub>T</sub> ≤ 1000 MeV, and (h) 1000 < k<sub>T</sub> ≤ 1500 MeV. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample k<sub>T</sub> - intervals∶ (a) 100 < k<sub>T</sub> ≤ 200 MeV, (b) 200 < k<sub>T</sub> ≤ 300 MeV, (c) 300 < k<sub>T</sub> ≤ 400 MeV, (d) 400 < k<sub>T</sub> ≤ 500 MeV, (e) 500 < k<sub>T</sub> ≤ 600 MeV, (f) 600 < k<sub>T</sub> ≤ 700 MeV, (g) 700 < k<sub>T</sub> ≤ 1000 MeV, and (h) 1000 < k<sub>T</sub> ≤ 1500 MeV. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample k<sub>T</sub> - intervals∶ (a) 100 < k<sub>T</sub> ≤ 200 MeV, (b) 200 < k<sub>T</sub> ≤ 300 MeV, (c) 300 < k<sub>T</sub> ≤ 400 MeV, (d) 400 < k<sub>T</sub> ≤ 500 MeV, (e) 500 < k<sub>T</sub> ≤ 600 MeV, (f) 600 < k<sub>T</sub> ≤ 700 MeV, (g) 700 < k<sub>T</sub> ≤ 1000 MeV, and (h) 1000 < k<sub>T</sub> ≤ 1500 MeV. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample k<sub>T</sub> - intervals∶ (a) 100 < k<sub>T</sub> ≤ 200 MeV, (b) 200 < k<sub>T</sub> ≤ 300 MeV, (c) 300 < k<sub>T</sub> ≤ 400 MeV, (d) 400 < k<sub>T</sub> ≤ 500 MeV, (e) 500 < k<sub>T</sub> ≤ 600 MeV, (f) 600 < k<sub>T</sub> ≤ 700 MeV, (g) 700 < k<sub>T</sub> ≤ 1000 MeV, and (h) 1000 < k<sub>T</sub> ≤ 1500 MeV. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the high-multiplicity track (HMT) events using the unlike-charge particle (UCP) pairs reference sample for k<sub>T</sub> - intervals∶ (a) 100 < k<sub>T</sub> ≤ 200 MeV, (b) 200 < k<sub>T</sub> ≤ 300 MeV, (c) 300 < k<sub>T</sub> ≤ 400 MeV, (d) 400 < k<sub>T</sub> ≤ 500 MeV, (e) 500 < k<sub>T</sub> ≤ 600 MeV, (f) 600 < k<sub>T</sub> ≤ 700 MeV, (g) 700 < k<sub>T</sub> ≤ 1000 MeV, and (h) 1000 < k<sub>T</sub> ≤ 1500 MeV. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the high-multiplicity track (HMT) events using the unlike-charge particle (UCP) pairs reference sample for k<sub>T</sub> - intervals∶ (a) 100 < k<sub>T</sub> ≤ 200 MeV, (b) 200 < k<sub>T</sub> ≤ 300 MeV, (c) 300 < k<sub>T</sub> ≤ 400 MeV, (d) 400 < k<sub>T</sub> ≤ 500 MeV, (e) 500 < k<sub>T</sub> ≤ 600 MeV, (f) 600 < k<sub>T</sub> ≤ 700 MeV, (g) 700 < k<sub>T</sub> ≤ 1000 MeV, and (h) 1000 < k<sub>T</sub> ≤ 1500 MeV. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the high-multiplicity track (HMT) events using the unlike-charge particle (UCP) pairs reference sample for k<sub>T</sub> - intervals∶ (a) 100 < k<sub>T</sub> ≤ 200 MeV, (b) 200 < k<sub>T</sub> ≤ 300 MeV, (c) 300 < k<sub>T</sub> ≤ 400 MeV, (d) 400 < k<sub>T</sub> ≤ 500 MeV, (e) 500 < k<sub>T</sub> ≤ 600 MeV, (f) 600 < k<sub>T</sub> ≤ 700 MeV, (g) 700 < k<sub>T</sub> ≤ 1000 MeV, and (h) 1000 < k<sub>T</sub> ≤ 1500 MeV. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the high-multiplicity track (HMT) events using the unlike-charge particle (UCP) pairs reference sample for k<sub>T</sub> - intervals∶ (a) 100 < k<sub>T</sub> ≤ 200 MeV, (b) 200 < k<sub>T</sub> ≤ 300 MeV, (c) 300 < k<sub>T</sub> ≤ 400 MeV, (d) 400 < k<sub>T</sub> ≤ 500 MeV, (e) 500 < k<sub>T</sub> ≤ 600 MeV, (f) 600 < k<sub>T</sub> ≤ 700 MeV, (g) 700 < k<sub>T</sub> ≤ 1000 MeV, and (h) 1000 < k<sub>T</sub> ≤ 1500 MeV. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the high-multiplicity track (HMT) events using the unlike-charge particle (UCP) pairs reference sample for k<sub>T</sub> - intervals∶ (a) 100 < k<sub>T</sub> ≤ 200 MeV, (b) 200 < k<sub>T</sub> ≤ 300 MeV, (c) 300 < k<sub>T</sub> ≤ 400 MeV, (d) 400 < k<sub>T</sub> ≤ 500 MeV, (e) 500 < k<sub>T</sub> ≤ 600 MeV, (f) 600 < k<sub>T</sub> ≤ 700 MeV, (g) 700 < k<sub>T</sub> ≤ 1000 MeV, and (h) 1000 < k<sub>T</sub> ≤ 1500 MeV. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the high-multiplicity track (HMT) events using the unlike-charge particle (UCP) pairs reference sample for k<sub>T</sub> - intervals∶ (a) 100 < k<sub>T</sub> ≤ 200 MeV, (b) 200 < k<sub>T</sub> ≤ 300 MeV, (c) 300 < k<sub>T</sub> ≤ 400 MeV, (d) 400 < k<sub>T</sub> ≤ 500 MeV, (e) 500 < k<sub>T</sub> ≤ 600 MeV, (f) 600 < k<sub>T</sub> ≤ 700 MeV, (g) 700 < k<sub>T</sub> ≤ 1000 MeV, and (h) 1000 < k<sub>T</sub> ≤ 1500 MeV. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the high-multiplicity track (HMT) events using the unlike-charge particle (UCP) pairs reference sample for k<sub>T</sub> - intervals∶ (a) 100 < k<sub>T</sub> ≤ 200 MeV, (b) 200 < k<sub>T</sub> ≤ 300 MeV, (c) 300 < k<sub>T</sub> ≤ 400 MeV, (d) 400 < k<sub>T</sub> ≤ 500 MeV, (e) 500 < k<sub>T</sub> ≤ 600 MeV, (f) 600 < k<sub>T</sub> ≤ 700 MeV, (g) 700 < k<sub>T</sub> ≤ 1000 MeV, and (h) 1000 < k<sub>T</sub> ≤ 1500 MeV. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), for the high-multiplicity track (HMT) events using the unlike-charge particle (UCP) pairs reference sample for k<sub>T</sub> - intervals∶ (a) 100 < k<sub>T</sub> ≤ 200 MeV, (b) 200 < k<sub>T</sub> ≤ 300 MeV, (c) 300 < k<sub>T</sub> ≤ 400 MeV, (d) 400 < k<sub>T</sub> ≤ 500 MeV, (e) 500 < k<sub>T</sub> ≤ 600 MeV, (f) 600 < k<sub>T</sub> ≤ 700 MeV, (g) 700 < k<sub>T</sub> ≤ 1000 MeV, and (h) 1000 < k<sub>T</sub> ≤ 1500 MeV. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), at 7 TeV for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 2 < n<sub>ch</sub> ≤ 9, (b) 10 < n<sub>ch</sub> ≤ 18, (c) 19 < n<sub>ch</sub> ≤ 27, (d) 28 < n<sub>ch</sub> ≤ 36, (e) 37 < n<sub>ch</sub> ≤ 45, (f) 46 < n<sub>ch</sub> ≤ 54, (g) 55 < n<sub>ch</sub> ≤ 63, (h) 64 < n<sub>ch</sub> ≤ 72, (i) 73 < n<sub>ch</sub> ≤ 81, (j) 82 < n<sub>ch</sub> ≤ 90, (k) 91 < n<sub>ch</sub> ≤ 113, and (l) 114 < n<sub>ch</sub> ≤ 136. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), at 7 TeV for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 2 < n<sub>ch</sub> ≤ 9, (b) 10 < n<sub>ch</sub> ≤ 18, (c) 19 < n<sub>ch</sub> ≤ 27, (d) 28 < n<sub>ch</sub> ≤ 36, (e) 37 < n<sub>ch</sub> ≤ 45, (f) 46 < n<sub>ch</sub> ≤ 54, (g) 55 < n<sub>ch</sub> ≤ 63, (h) 64 < n<sub>ch</sub> ≤ 72, (i) 73 < n<sub>ch</sub> ≤ 81, (j) 82 < n<sub>ch</sub> ≤ 90, (k) 91 < n<sub>ch</sub> ≤ 113, and (l) 114 < n<sub>ch</sub> ≤ 136. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), at 7 TeV for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 2 < n<sub>ch</sub> ≤ 9, (b) 10 < n<sub>ch</sub> ≤ 18, (c) 19 < n<sub>ch</sub> ≤ 27, (d) 28 < n<sub>ch</sub> ≤ 36, (e) 37 < n<sub>ch</sub> ≤ 45, (f) 46 < n<sub>ch</sub> ≤ 54, (g) 55 < n<sub>ch</sub> ≤ 63, (h) 64 < n<sub>ch</sub> ≤ 72, (i) 73 < n<sub>ch</sub> ≤ 81, (j) 82 < n<sub>ch</sub> ≤ 90, (k) 91 < n<sub>ch</sub> ≤ 113, and (l) 114 < n<sub>ch</sub> ≤ 136. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), at 7 TeV for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 2 < n<sub>ch</sub> ≤ 9, (b) 10 < n<sub>ch</sub> ≤ 18, (c) 19 < n<sub>ch</sub> ≤ 27, (d) 28 < n<sub>ch</sub> ≤ 36, (e) 37 < n<sub>ch</sub> ≤ 45, (f) 46 < n<sub>ch</sub> ≤ 54, (g) 55 < n<sub>ch</sub> ≤ 63, (h) 64 < n<sub>ch</sub> ≤ 72, (i) 73 < n<sub>ch</sub> ≤ 81, (j) 82 < n<sub>ch</sub> ≤ 90, (k) 91 < n<sub>ch</sub> ≤ 113, and (l) 114 < n<sub>ch</sub> ≤ 136. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), at 7 TeV for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 2 < n<sub>ch</sub> ≤ 9, (b) 10 < n<sub>ch</sub> ≤ 18, (c) 19 < n<sub>ch</sub> ≤ 27, (d) 28 < n<sub>ch</sub> ≤ 36, (e) 37 < n<sub>ch</sub> ≤ 45, (f) 46 < n<sub>ch</sub> ≤ 54, (g) 55 < n<sub>ch</sub> ≤ 63, (h) 64 < n<sub>ch</sub> ≤ 72, (i) 73 < n<sub>ch</sub> ≤ 81, (j) 82 < n<sub>ch</sub> ≤ 90, (k) 91 < n<sub>ch</sub> ≤ 113, and (l) 114 < n<sub>ch</sub> ≤ 136. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), at 7 TeV for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 2 < n<sub>ch</sub> ≤ 9, (b) 10 < n<sub>ch</sub> ≤ 18, (c) 19 < n<sub>ch</sub> ≤ 27, (d) 28 < n<sub>ch</sub> ≤ 36, (e) 37 < n<sub>ch</sub> ≤ 45, (f) 46 < n<sub>ch</sub> ≤ 54, (g) 55 < n<sub>ch</sub> ≤ 63, (h) 64 < n<sub>ch</sub> ≤ 72, (i) 73 < n<sub>ch</sub> ≤ 81, (j) 82 < n<sub>ch</sub> ≤ 90, (k) 91 < n<sub>ch</sub> ≤ 113, and (l) 114 < n<sub>ch</sub> ≤ 136. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), at 7 TeV for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 2 < n<sub>ch</sub> ≤ 9, (b) 10 < n<sub>ch</sub> ≤ 18, (c) 19 < n<sub>ch</sub> ≤ 27, (d) 28 < n<sub>ch</sub> ≤ 36, (e) 37 < n<sub>ch</sub> ≤ 45, (f) 46 < n<sub>ch</sub> ≤ 54, (g) 55 < n<sub>ch</sub> ≤ 63, (h) 64 < n<sub>ch</sub> ≤ 72, (i) 73 < n<sub>ch</sub> ≤ 81, (j) 82 < n<sub>ch</sub> ≤ 90, (k) 91 < n<sub>ch</sub> ≤ 113, and (l) 114 < n<sub>ch</sub> ≤ 136. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), at 7 TeV for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 2 < n<sub>ch</sub> ≤ 9, (b) 10 < n<sub>ch</sub> ≤ 18, (c) 19 < n<sub>ch</sub> ≤ 27, (d) 28 < n<sub>ch</sub> ≤ 36, (e) 37 < n<sub>ch</sub> ≤ 45, (f) 46 < n<sub>ch</sub> ≤ 54, (g) 55 < n<sub>ch</sub> ≤ 63, (h) 64 < n<sub>ch</sub> ≤ 72, (i) 73 < n<sub>ch</sub> ≤ 81, (j) 82 < n<sub>ch</sub> ≤ 90, (k) 91 < n<sub>ch</sub> ≤ 113, and (l) 114 < n<sub>ch</sub> ≤ 136. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), at 7 TeV for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 2 < n<sub>ch</sub> ≤ 9, (b) 10 < n<sub>ch</sub> ≤ 18, (c) 19 < n<sub>ch</sub> ≤ 27, (d) 28 < n<sub>ch</sub> ≤ 36, (e) 37 < n<sub>ch</sub> ≤ 45, (f) 46 < n<sub>ch</sub> ≤ 54, (g) 55 < n<sub>ch</sub> ≤ 63, (h) 64 < n<sub>ch</sub> ≤ 72, (i) 73 < n<sub>ch</sub> ≤ 81, (j) 82 < n<sub>ch</sub> ≤ 90, (k) 91 < n<sub>ch</sub> ≤ 113, and (l) 114 < n<sub>ch</sub> ≤ 136. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), at 7 TeV for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 2 < n<sub>ch</sub> ≤ 9, (b) 10 < n<sub>ch</sub> ≤ 18, (c) 19 < n<sub>ch</sub> ≤ 27, (d) 28 < n<sub>ch</sub> ≤ 36, (e) 37 < n<sub>ch</sub> ≤ 45, (f) 46 < n<sub>ch</sub> ≤ 54, (g) 55 < n<sub>ch</sub> ≤ 63, (h) 64 < n<sub>ch</sub> ≤ 72, (i) 73 < n<sub>ch</sub> ≤ 81, (j) 82 < n<sub>ch</sub> ≤ 90, (k) 91 < n<sub>ch</sub> ≤ 113, and (l) 114 < n<sub>ch</sub> ≤ 136. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), at 7 TeV for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 2 < n<sub>ch</sub> ≤ 9, (b) 10 < n<sub>ch</sub> ≤ 18, (c) 19 < n<sub>ch</sub> ≤ 27, (d) 28 < n<sub>ch</sub> ≤ 36, (e) 37 < n<sub>ch</sub> ≤ 45, (f) 46 < n<sub>ch</sub> ≤ 54, (g) 55 < n<sub>ch</sub> ≤ 63, (h) 64 < n<sub>ch</sub> ≤ 72, (i) 73 < n<sub>ch</sub> ≤ 81, (j) 82 < n<sub>ch</sub> ≤ 90, (k) 91 < n<sub>ch</sub> ≤ 113, and (l) 114 < n<sub>ch</sub> ≤ 136. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), at 7 TeV for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample for n<sub>ch</sub> - intervals∶ (a) 2 < n<sub>ch</sub> ≤ 9, (b) 10 < n<sub>ch</sub> ≤ 18, (c) 19 < n<sub>ch</sub> ≤ 27, (d) 28 < n<sub>ch</sub> ≤ 36, (e) 37 < n<sub>ch</sub> ≤ 45, (f) 46 < n<sub>ch</sub> ≤ 54, (g) 55 < n<sub>ch</sub> ≤ 63, (h) 64 < n<sub>ch</sub> ≤ 72, (i) 73 < n<sub>ch</sub> ≤ 81, (j) 82 < n<sub>ch</sub> ≤ 90, (k) 91 < n<sub>ch</sub> ≤ 113, and (l) 114 < n<sub>ch</sub> ≤ 136. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), at 7 TeV for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample k<sub>T</sub> - intervals∶ (a) 100 < k<sub>T</sub> ≤ 200 MeV, (b) 200 < k<sub>T</sub> ≤ 300 MeV, (c) 300 < k<sub>T</sub> ≤ 400 MeV, (d) 400 < k<sub>T</sub> ≤ 500 MeV, (e) 500 < k<sub>T</sub> ≤ 600 MeV, (f) 600 < k<sub>T</sub> ≤ 700 MeV, (g) 700 < k<sub>T</sub> ≤ 1000 MeV, and (h) 1000 < k<sub>T</sub> ≤ 1500 MeV. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), at 7 TeV for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample k<sub>T</sub> - intervals∶ (a) 100 < k<sub>T</sub> ≤ 200 MeV, (b) 200 < k<sub>T</sub> ≤ 300 MeV, (c) 300 < k<sub>T</sub> ≤ 400 MeV, (d) 400 < k<sub>T</sub> ≤ 500 MeV, (e) 500 < k<sub>T</sub> ≤ 600 MeV, (f) 600 < k<sub>T</sub> ≤ 700 MeV, (g) 700 < k<sub>T</sub> ≤ 1000 MeV, and (h) 1000 < k<sub>T</sub> ≤ 1500 MeV. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), at 7 TeV for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample k<sub>T</sub> - intervals∶ (a) 100 < k<sub>T</sub> ≤ 200 MeV, (b) 200 < k<sub>T</sub> ≤ 300 MeV, (c) 300 < k<sub>T</sub> ≤ 400 MeV, (d) 400 < k<sub>T</sub> ≤ 500 MeV, (e) 500 < k<sub>T</sub> ≤ 600 MeV, (f) 600 < k<sub>T</sub> ≤ 700 MeV, (g) 700 < k<sub>T</sub> ≤ 1000 MeV, and (h) 1000 < k<sub>T</sub> ≤ 1500 MeV. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), at 7 TeV for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample k<sub>T</sub> - intervals∶ (a) 100 < k<sub>T</sub> ≤ 200 MeV, (b) 200 < k<sub>T</sub> ≤ 300 MeV, (c) 300 < k<sub>T</sub> ≤ 400 MeV, (d) 400 < k<sub>T</sub> ≤ 500 MeV, (e) 500 < k<sub>T</sub> ≤ 600 MeV, (f) 600 < k<sub>T</sub> ≤ 700 MeV, (g) 700 < k<sub>T</sub> ≤ 1000 MeV, and (h) 1000 < k<sub>T</sub> ≤ 1500 MeV. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), at 7 TeV for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample k<sub>T</sub> - intervals∶ (a) 100 < k<sub>T</sub> ≤ 200 MeV, (b) 200 < k<sub>T</sub> ≤ 300 MeV, (c) 300 < k<sub>T</sub> ≤ 400 MeV, (d) 400 < k<sub>T</sub> ≤ 500 MeV, (e) 500 < k<sub>T</sub> ≤ 600 MeV, (f) 600 < k<sub>T</sub> ≤ 700 MeV, (g) 700 < k<sub>T</sub> ≤ 1000 MeV, and (h) 1000 < k<sub>T</sub> ≤ 1500 MeV. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), at 7 TeV for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample k<sub>T</sub> - intervals∶ (a) 100 < k<sub>T</sub> ≤ 200 MeV, (b) 200 < k<sub>T</sub> ≤ 300 MeV, (c) 300 < k<sub>T</sub> ≤ 400 MeV, (d) 400 < k<sub>T</sub> ≤ 500 MeV, (e) 500 < k<sub>T</sub> ≤ 600 MeV, (f) 600 < k<sub>T</sub> ≤ 700 MeV, (g) 700 < k<sub>T</sub> ≤ 1000 MeV, and (h) 1000 < k<sub>T</sub> ≤ 1500 MeV. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), at 7 TeV for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample k<sub>T</sub> - intervals∶ (a) 100 < k<sub>T</sub> ≤ 200 MeV, (b) 200 < k<sub>T</sub> ≤ 300 MeV, (c) 300 < k<sub>T</sub> ≤ 400 MeV, (d) 400 < k<sub>T</sub> ≤ 500 MeV, (e) 500 < k<sub>T</sub> ≤ 600 MeV, (f) 600 < k<sub>T</sub> ≤ 700 MeV, (g) 700 < k<sub>T</sub> ≤ 1000 MeV, and (h) 1000 < k<sub>T</sub> ≤ 1500 MeV. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The single-ratio two-particle correlation functions, C<sub>2</sub><sup>data</sup>(Q), at 7 TeV for the minimum-bias (MB) events using the unlike-charge particle (UCP) pairs reference sample k<sub>T</sub> - intervals∶ (a) 100 < k<sub>T</sub> ≤ 200 MeV, (b) 200 < k<sub>T</sub> ≤ 300 MeV, (c) 300 < k<sub>T</sub> ≤ 400 MeV, (d) 400 < k<sub>T</sub> ≤ 500 MeV, (e) 500 < k<sub>T</sub> ≤ 600 MeV, (f) 600 < k<sub>T</sub> ≤ 700 MeV, (g) 700 < k<sub>T</sub> ≤ 1000 MeV, and (h) 1000 < k<sub>T</sub> ≤ 1500 MeV. The error bars represent the statistical uncertainties. The boxes represent the systematic uncertainties, which are the sum in quadrature of a variation of the Coulomb correction, the track reconstruction efficiency and the unfolding matrix.
The correlation strength, λ, and source radius, R, of the exponential fits to the two-particle double-ratio correlation functions, R<sub>2</sub>(Q), in dependence on the multiplicity, m<sub>ch</sub>, intervals for the minimum-bias (MB) and the high-multiplicity track (HMT) events for p<sub>T</sub> > 100 MeV at √s = 13 TeV. Statistical uncertainties for √χ<sup>2</sup>/ndf>1 are corrected by the √χ<sup>2</sup>/ndf. The total uncertainties are shown.
The correlation strength, λ, and source radius, R, of the exponential fits to the two-particle double-ratio correlation functions, R<sub>2</sub>(Q), in dependence on the multiplicity, m<sub>ch</sub>, intervals for the minimum-bias (MB) and the high-multiplicity track (HMT) events for p<sub>T</sub> > 500 MeV at √s = 13 TeV. Statistical uncertainties for √χ<sup>2</sup>/ndf>1 are corrected by the √χ<sup>2</sup>/ndf. The total uncertainties are shown.
The correlation strength, λ, and source radius, R, of the exponential fits to the two-particle double-ratio correlation functions, R<sub>2</sub>(Q), in dependence on the pair transverse momentum, k<sub>T</sub>, intervals for the minimum-bias (MB) and the high-multiplicity track (HMT) events for p<sub>T</sub> > 100 MeV at √s = 13 TeV. Statistical uncertainties for √χ<sup>2</sup>/ndf>1 are corrected by the √χ<sup>2</sup>/ndf. The total uncertainties are shown.
The correlation strength, λ, and source radius, R, of the exponential fits to the two-particle double-ratio correlation functions, R<sub>2</sub>(Q), in dependence on the pair transverse momentum, k<sub>T</sub>, intervals for the minimum-bias (MB) and the high-multiplicity track (HMT) events for p<sub>T</sub> > 500 MeV at √s = 13 TeV. Statistical uncertainties for √χ<sup>2</sup>/ndf>1 are corrected by the √χ<sup>2</sup>/ndf. The total uncertainties are shown.
This paper presents results of searches for electroweak production of supersymmetric particles in models with compressed mass spectra. The searches use 139 fb$^{-1}$ of $\sqrt{s}=13$ TeV proton-proton collision data collected by the ATLAS experiment at the Large Hadron Collider. Events with missing transverse momentum and two same-flavor, oppositely charged, low transverse momentum leptons are selected, and are further categorized by the presence of hadronic activity from initial-state radiation or a topology compatible with vector-boson fusion processes. The data are found to be consistent with predictions from the Standard Model. The results are interpreted using simplified models of $R$-parity-conserving supersymmetry in which the lightest supersymmetric partner is a neutralino with a mass similar to the lightest chargino, the second-to-lightest neutralino or the slepton. Lower limits on the masses of charginos in different simplified models range from 193 GeV to 240 GeV for moderate mass splittings, and extend down to mass splittings of 1.5 GeV to 2.4 GeV at the LEP chargino bounds (92.4 GeV). Similar lower limits on degenerate light-flavor sleptons extend up to masses of 251 GeV and down to mass splittings of 550 MeV. Constraints on vector-boson fusion production of electroweak SUSY states are also presented.
Expected 95% CL exclusion sensitivity for simplified models of direct higgsino production.
Expected 95% CL exclusion sensitivity for simplified models of direct higgsino production.
Expected 95% CL exclusion sensitivity for simplified models of direct higgsino production.
Expected 95% CL exclusion sensitivity for simplified models of direct higgsino production.
Expected 95% CL exclusion sensitivity for simplified models of direct higgsino production.
Observed 95% CL exclusion sensitivity for simplified models of direct higgsino production.
Observed 95% CL exclusion sensitivity for simplified models of direct higgsino production.
Observed 95% CL exclusion sensitivity for simplified models of direct higgsino production.
Observed 95% CL exclusion sensitivity for simplified models of direct higgsino production.
Observed 95% CL exclusion sensitivity for simplified models of direct higgsino production.
Expected 95% CL exclusion sensitivity for simplified models of direct wino-bino production, assuming $m(\tilde{\chi}_{2}^{0}) \times m(\tilde{\chi}_{1}^{0})<0$.
Expected 95% CL exclusion sensitivity for simplified models of direct wino-bino production, assuming $m(\tilde{\chi}_{2}^{0}) \times m(\tilde{\chi}_{1}^{0})<0$.
Expected 95% CL exclusion sensitivity for simplified models of direct wino-bino production, assuming $m(\tilde{\chi}_{2}^{0}) \times m(\tilde{\chi}_{1}^{0})<0$.
Expected 95% CL exclusion sensitivity for simplified models of direct wino-bino production, assuming $m(\tilde{\chi}_{2}^{0}) \times m(\tilde{\chi}_{1}^{0})<0$.
Expected 95% CL exclusion sensitivity for simplified models of direct wino-bino production, assuming $m(\tilde{\chi}_{2}^{0}) \times m(\tilde{\chi}_{1}^{0})<0$.
Observed 95% CL exclusion sensitivity for simplified models of direct wino-bino production, assuming $m(\tilde{\chi}_{2}^{0}) \times m(\tilde{\chi}_{1}^{0})<0$.
Observed 95% CL exclusion sensitivity for simplified models of direct wino-bino production, assuming $m(\tilde{\chi}_{2}^{0}) \times m(\tilde{\chi}_{1}^{0})<0$.
Observed 95% CL exclusion sensitivity for simplified models of direct wino-bino production, assuming $m(\tilde{\chi}_{2}^{0}) \times m(\tilde{\chi}_{1}^{0})<0$.
Observed 95% CL exclusion sensitivity for simplified models of direct wino-bino production, assuming $m(\tilde{\chi}_{2}^{0}) \times m(\tilde{\chi}_{1}^{0})<0$.
Observed 95% CL exclusion sensitivity for simplified models of direct wino-bino production, assuming $m(\tilde{\chi}_{2}^{0}) \times m(\tilde{\chi}_{1}^{0})<0$.
Expected 95% CL exclusion sensitivity for simplified models of direct wino-bino production, assuming $m(\tilde{\chi}_{2}^{0}) \times m(\tilde{\chi}_{1}^{0})>0$.
Expected 95% CL exclusion sensitivity for simplified models of direct wino-bino production, assuming $m(\tilde{\chi}_{2}^{0}) \times m(\tilde{\chi}_{1}^{0})>0$.
Expected 95% CL exclusion sensitivity for simplified models of direct wino-bino production, assuming $m(\tilde{\chi}_{2}^{0}) \times m(\tilde{\chi}_{1}^{0})>0$.
Expected 95% CL exclusion sensitivity for simplified models of direct wino-bino production, assuming $m(\tilde{\chi}_{2}^{0}) \times m(\tilde{\chi}_{1}^{0})>0$.
Expected 95% CL exclusion sensitivity for simplified models of direct wino-bino production, assuming $m(\tilde{\chi}_{2}^{0}) \times m(\tilde{\chi}_{1}^{0})>0$.
Observed 95% CL exclusion sensitivity for simplified models of direct wino-bino production, assuming $m(\tilde{\chi}_{2}^{0}) \times m(\tilde{\chi}_{1}^{0})>0$.
Observed 95% CL exclusion sensitivity for simplified models of direct wino-bino production, assuming $m(\tilde{\chi}_{2}^{0}) \times m(\tilde{\chi}_{1}^{0})>0$.
Observed 95% CL exclusion sensitivity for simplified models of direct wino-bino production, assuming $m(\tilde{\chi}_{2}^{0}) \times m(\tilde{\chi}_{1}^{0})>0$.
Observed 95% CL exclusion sensitivity for simplified models of direct wino-bino production, assuming $m(\tilde{\chi}_{2}^{0}) \times m(\tilde{\chi}_{1}^{0})>0$.
Observed 95% CL exclusion sensitivity for simplified models of direct wino-bino production, assuming $m(\tilde{\chi}_{2}^{0}) \times m(\tilde{\chi}_{1}^{0})>0$.
Expected 95% CL exclusion sensitivity for simplified models of VBF wino-bino production.
Expected 95% CL exclusion sensitivity for simplified models of VBF wino-bino production.
Expected 95% CL exclusion sensitivity for simplified models of VBF wino-bino production.
Expected 95% CL exclusion sensitivity for simplified models of VBF wino-bino production.
Expected 95% CL exclusion sensitivity for simplified models of VBF wino-bino production.
Observed 95% CL exclusion sensitivity for simplified models of direct wino-bino production.
Observed 95% CL exclusion sensitivity for simplified models of direct wino-bino production.
Observed 95% CL exclusion sensitivity for simplified models of direct wino-bino production.
Observed 95% CL exclusion sensitivity for simplified models of direct wino-bino production.
Observed 95% CL exclusion sensitivity for simplified models of direct wino-bino production.
Expected 95% CL exclusion sensitivity for simplified models of direct slepton production.
Expected 95% CL exclusion sensitivity for simplified models of direct slepton production.
Expected 95% CL exclusion sensitivity for simplified models of direct slepton production.
Expected 95% CL exclusion sensitivity for simplified models of direct slepton production.
Expected 95% CL exclusion sensitivity for simplified models of direct slepton production.
Observed 95% CL exclusion sensitivity for simplified models of direct slepton production.
Observed 95% CL exclusion sensitivity for simplified models of direct slepton production.
Observed 95% CL exclusion sensitivity for simplified models of direct slepton production.
Observed 95% CL exclusion sensitivity for simplified models of direct slepton production.
Observed 95% CL exclusion sensitivity for simplified models of direct slepton production.
Expected 95% CL exclusion sensitivity for simplified models of direct LH smuon production.
Expected 95% CL exclusion sensitivity for simplified models of direct LH smuon production.
Expected 95% CL exclusion sensitivity for simplified models of direct smuon production.
Expected 95% CL exclusion sensitivity for simplified models of direct smuon production.
Expected 95% CL exclusion sensitivity for simplified models of direct smuon production.
Observed 95% CL exclusion sensitivity for simplified models of direct LH smuon production.
Observed 95% CL exclusion sensitivity for simplified models of direct LH smuon production.
Observed 95% CL exclusion sensitivity for simplified models of direct smuon production.
Observed 95% CL exclusion sensitivity for simplified models of direct smuon production.
Observed 95% CL exclusion sensitivity for simplified models of direct smuon production.
Expected 95% CL exclusion sensitivity for simplified models of direct RH smuon production.
Expected 95% CL exclusion sensitivity for simplified models of direct RH smuon production.
Expected 95% CL exclusion sensitivity for simplified models of direct selectron production.
Expected 95% CL exclusion sensitivity for simplified models of direct selectron production.
Expected 95% CL exclusion sensitivity for simplified models of direct selectron production.
Observed 95% CL exclusion sensitivity for simplified models of direct RH smuon production.
Observed 95% CL exclusion sensitivity for simplified models of direct RH smuon production.
Observed 95% CL exclusion sensitivity for simplified models of direct selectron production.
Observed 95% CL exclusion sensitivity for simplified models of direct selectron production.
Observed 95% CL exclusion sensitivity for simplified models of direct selectron production.
Expected 95% CL exclusion sensitivity for simplified models of direct LH selectron production.
Expected 95% CL exclusion sensitivity for simplified models of direct LH selectron production.
Expected 95% CL exclusion sensitivity for simplified models of direct LH slepton production.
Expected 95% CL exclusion sensitivity for simplified models of direct LH slepton production.
Expected 95% CL exclusion sensitivity for simplified models of direct LH slepton production.
Observed 95% CL exclusion sensitivity for simplified models of direct LH selectron production.
Observed 95% CL exclusion sensitivity for simplified models of direct LH selectron production.
Observed 95% CL exclusion sensitivity for simplified models of direct LH slepton production.
Observed 95% CL exclusion sensitivity for simplified models of direct LH slepton production.
Observed 95% CL exclusion sensitivity for simplified models of direct LH slepton production.
Expected 95% CL exclusion sensitivity for simplified models of direct RH selectron production.
Expected 95% CL exclusion sensitivity for simplified models of direct RH selectron production.
Expected 95% CL exclusion sensitivity for simplified models of direct RH slepton production.
Expected 95% CL exclusion sensitivity for simplified models of direct RH slepton production.
Expected 95% CL exclusion sensitivity for simplified models of direct RH slepton production.
Observed 95% CL exclusion sensitivity for simplified models of direct RH selectron production.
Observed 95% CL exclusion sensitivity for simplified models of direct RH selectron production.
Observed 95% CL exclusion sensitivity for simplified models of direct RH slepton production.
Observed 95% CL exclusion sensitivity for simplified models of direct RH slepton production.
Observed 95% CL exclusion sensitivity for simplified models of direct RH slepton production.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the C1C1 higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the C1C1 higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Expected 95% CL exclusion sensitivity for simplified models of direct LH smuon production.
Expected 95% CL exclusion sensitivity for simplified models of direct LH smuon production.
Expected 95% CL exclusion sensitivity for simplified models of direct LH smuon production.
Efficiency for the C1C1 higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the C1C1 higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Observed 95% CL exclusion sensitivity for simplified models of direct LH smuon production.
Observed 95% CL exclusion sensitivity for simplified models of direct LH smuon production.
Observed 95% CL exclusion sensitivity for simplified models of direct LH smuon production.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the C1C1 higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the C1C1 higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Expected 95% CL exclusion sensitivity for simplified models of direct RH smuon production.
Expected 95% CL exclusion sensitivity for simplified models of direct RH smuon production.
Expected 95% CL exclusion sensitivity for simplified models of direct RH smuon production.
Efficiency for the C1C1 higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the C1C1 higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Observed 95% CL exclusion sensitivity for simplified models of direct RH smuon production.
Observed 95% CL exclusion sensitivity for simplified models of direct RH smuon production.
Observed 95% CL exclusion sensitivity for simplified models of direct RH smuon production.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the C1C1 higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the C1C1 higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Expected 95% CL exclusion sensitivity for simplified models of direct LH selectron production.
Expected 95% CL exclusion sensitivity for simplified models of direct LH selectron production.
Expected 95% CL exclusion sensitivity for simplified models of direct LH selectron production.
Efficiency for the C1C1 higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the C1C1 higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Observed 95% CL exclusion sensitivity for simplified models of direct LH selectron production.
Observed 95% CL exclusion sensitivity for simplified models of direct LH selectron production.
Observed 95% CL exclusion sensitivity for simplified models of direct LH selectron production.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Expected 95% CL exclusion sensitivity for simplified models of direct RH selectron production.
Expected 95% CL exclusion sensitivity for simplified models of direct RH selectron production.
Expected 95% CL exclusion sensitivity for simplified models of direct RH selectron production.
Efficiency for the N2N1 higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2N1 higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Observed 95% CL exclusion sensitivity for simplified models of direct RH selectron production.
Observed 95% CL exclusion sensitivity for simplified models of direct RH selectron production.
Observed 95% CL exclusion sensitivity for simplified models of direct RH selectron production.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the C1C1 higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the C1C1 higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the C1C1 higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2N1 higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2N1 higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the C1C1 higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the C1C1 higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the C1C1 higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the C1C1 higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the C1C1 higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the C1C1 higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2N1 higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2N1 higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the C1C1 higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the C1C1 higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the C1C1 higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 higgsino process in the SR-E-1l1T region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 higgsino process in the SR-E-1l1T region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the C1C1 higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the C1C1 higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the C1C1 higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2N1 higgsino process in the SR-E-1l1T region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2N1 higgsino process in the SR-E-1l1T region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the C1C1 higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the C1C1 higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the C1C1 higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1p higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1p higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2N1 higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2N1 higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2N1 higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1p higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1p higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2N1 higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2N1 higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2N1 higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1p higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1p higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2N1 higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2N1 higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2N1 higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p higgsino process in the SR-E-1l1T region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p higgsino process in the SR-E-1l1T region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 higgsino process in the SR-E-1l1T region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 higgsino process in the SR-E-1l1T region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 higgsino process in the SR-E-1l1T region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1p higgsino process in the SR-E-1l1T region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1p higgsino process in the SR-E-1l1T region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2N1 higgsino process in the SR-E-1l1T region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2N1 higgsino process in the SR-E-1l1T region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2N1 higgsino process in the SR-E-1l1T region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1m higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1m higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1p higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1p higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1p higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1m higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1m higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1p higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1p higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1p higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1m higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1m higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1p higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1p higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1p higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m higgsino process in the SR-E-1l1T region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m higgsino process in the SR-E-1l1T region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p higgsino process in the SR-E-1l1T region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p higgsino process in the SR-E-1l1T region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p higgsino process in the SR-E-1l1T region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1m higgsino process in the SR-E-1l1T region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1m higgsino process in the SR-E-1l1T region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1p higgsino process in the SR-E-1l1T region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1p higgsino process in the SR-E-1l1T region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1p higgsino process in the SR-E-1l1T region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-3}$) for the slepton process in the SR-S region. Truth stransverse mass is constrained to be within the range [100,140] GeV.
Acceptance (note the $z$-axis is in units of $10^{-3}$) for the slepton process in the SR-S region. Truth stransverse mass is constrained to be within the range [100,140] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the slepton process in the SR-S region. Truth stransverse mass is constrained to be within the range [100,140] GeV.
Efficiency for the slepton process in the SR-S region. Truth stransverse mass is constrained to be within the range [100,140] GeV.
Efficiency for the N2C1m higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1m higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1m higgsino process in the SR-E-high region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-3}$) for the slepton process in the SR-S-high region. Truth stransverse mass is constrained to be within the range [100,140] GeV.
Acceptance (note the $z$-axis is in units of $10^{-3}$) for the slepton process in the SR-S-high region. Truth stransverse mass is constrained to be within the range [100,140] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the slepton process in the SR-S-high region. Truth stransverse mass is constrained to be within the range [100,140] GeV.
Efficiency for the slepton process in the SR-S-high region. Truth stransverse mass is constrained to be within the range [100,140] GeV.
Efficiency for the N2C1m higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1m higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1m higgsino process in the SR-E-low region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-3}$) for the slepton process in the SR-S-low region. Truth stransverse mass is constrained to be within the range [100,140] GeV.
Acceptance (note the $z$-axis is in units of $10^{-3}$) for the slepton process in the SR-S-low region. Truth stransverse mass is constrained to be within the range [100,140] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the slepton process in the SR-S-low region. Truth stransverse mass is constrained to be within the range [100,140] GeV.
Efficiency for the slepton process in the SR-S-low region. Truth stransverse mass is constrained to be within the range [100,140] GeV.
Efficiency for the N2C1m higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1m higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1m higgsino process in the SR-E-med region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the C1C1 VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the C1C1 VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m higgsino process in the SR-E-1l1T region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m higgsino process in the SR-E-1l1T region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m higgsino process in the SR-E-1l1T region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the C1C1 VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the C1C1 VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2C1m higgsino process in the SR-E-1l1T region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1m higgsino process in the SR-E-1l1T region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Efficiency for the N2C1m higgsino process in the SR-E-1l1T region. Truth dilepton invariant mass is constrained to be within the range [0.5,60] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the C1C1 VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the C1C1 VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-3}$) for the slepton process in the SR-S region. Truth stransverse mass is constrained to be within the range [100,140] GeV.
Acceptance (note the $z$-axis is in units of $10^{-3}$) for the slepton process in the SR-S region. Truth stransverse mass is constrained to be within the range [100,140] GeV.
Acceptance (note the $z$-axis is in units of $10^{-3}$) for the slepton process in the SR-S region. Truth stransverse mass is constrained to be within the range [100,140] GeV.
Efficiency for the C1C1 VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the C1C1 VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the slepton process in the SR-S region. Truth stransverse mass is constrained to be within the range [100,140] GeV.
Efficiency for the slepton process in the SR-S region. Truth stransverse mass is constrained to be within the range [100,140] GeV.
Efficiency for the slepton process in the SR-S region. Truth stransverse mass is constrained to be within the range [100,140] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the C1C1 VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the C1C1 VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-3}$) for the slepton process in the SR-S-high region. Truth stransverse mass is constrained to be within the range [100,140] GeV.
Acceptance (note the $z$-axis is in units of $10^{-3}$) for the slepton process in the SR-S-high region. Truth stransverse mass is constrained to be within the range [100,140] GeV.
Acceptance (note the $z$-axis is in units of $10^{-3}$) for the slepton process in the SR-S-high region. Truth stransverse mass is constrained to be within the range [100,140] GeV.
Efficiency for the C1C1 VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the C1C1 VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the slepton process in the SR-S-high region. Truth stransverse mass is constrained to be within the range [100,140] GeV.
Efficiency for the slepton process in the SR-S-high region. Truth stransverse mass is constrained to be within the range [100,140] GeV.
Efficiency for the slepton process in the SR-S-high region. Truth stransverse mass is constrained to be within the range [100,140] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-3}$) for the slepton process in the SR-S-low region. Truth stransverse mass is constrained to be within the range [100,140] GeV.
Acceptance (note the $z$-axis is in units of $10^{-3}$) for the slepton process in the SR-S-low region. Truth stransverse mass is constrained to be within the range [100,140] GeV.
Acceptance (note the $z$-axis is in units of $10^{-3}$) for the slepton process in the SR-S-low region. Truth stransverse mass is constrained to be within the range [100,140] GeV.
Efficiency for the N2N1 VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2N1 VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the slepton process in the SR-S-low region. Truth stransverse mass is constrained to be within the range [100,140] GeV.
Efficiency for the slepton process in the SR-S-low region. Truth stransverse mass is constrained to be within the range [100,140] GeV.
Efficiency for the slepton process in the SR-S-low region. Truth stransverse mass is constrained to be within the range [100,140] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the C1C1 VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the C1C1 VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the C1C1 VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2N1 VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2N1 VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the C1C1 VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the C1C1 VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the C1C1 VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the C1C1 VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the C1C1 VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the C1C1 VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2N1 VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2N1 VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the C1C1 VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the C1C1 VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the C1C1 VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the C1C1 VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the C1C1 VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the C1C1 VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2C1p VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2C1p VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the C1C1 VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the C1C1 VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the C1C1 VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2C1p VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2C1p VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2N1 VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2N1 VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2N1 VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2C1p VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2C1p VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2N1 VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2N1 VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2N1 VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2N1 VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2C1m VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2C1m VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2N1 VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2N1 VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2N1 VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2C1m VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2C1m VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2C1p VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2C1p VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2C1p VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2C1m VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2C1m VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2C1p VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2C1p VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2C1p VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Observed and Expected upper cross-section limits for wino-bino scenarios, assuming $m(\tilde{\chi}_{2}^{0}) \times m(\tilde{\chi}_{1}^{0})>0$.
Observed and Expected upper cross-section limits for wino-bino scenarios, assuming $m(\tilde{\chi}_{2}^{0}) \times m(\tilde{\chi}_{1}^{0})>0$.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1p VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Observed and Expected upper cross-section limits for wino-bino scenarios, assuming $m(\tilde{\chi}_{2}^{0}) \times m(\tilde{\chi}_{1}^{0})<0$.
Observed and Expected upper cross-section limits for wino-bino scenarios, assuming $m(\tilde{\chi}_{2}^{0}) \times m(\tilde{\chi}_{1}^{0})<0$.
Efficiency for the N2C1p VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2C1p VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2C1p VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Observed and Expected upper cross-section limits for higgsino scenarios.
Observed and Expected upper cross-section limits for higgsino scenarios.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Observed and Expected upper cross-section limits for higgsino scenarios, assuming VBF production..
Observed and Expected upper cross-section limits for higgsino scenarios, assuming VBF production..
Efficiency for the N2C1m VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2C1m VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2C1m VBF higgsino process in the SR-VBF-high region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Observed and Expected upper cross-section limits for direct slepton scenarios.
Observed and Expected upper cross-section limits for direct slepton scenarios.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Observed and Expected upper cross-section limits for direct LH slepton scenarios.
Observed and Expected upper cross-section limits for direct LH slepton scenarios.
Efficiency for the N2C1m VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2C1m VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2C1m VBF higgsino process in the SR-VBF-low region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Observed and Expected upper cross-section limits for direct RH slepton scenarios.
Observed and Expected upper cross-section limits for direct RH slepton scenarios.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Acceptance (note the $z$-axis is in units of $10^{-4}$) for the N2C1m VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Observed and Expected upper cross-section limits for direct smuon scenarios.
Observed and Expected upper cross-section limits for direct smuon scenarios.
Efficiency for the N2C1m VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2C1m VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Efficiency for the N2C1m VBF higgsino process in the SR-VBF region. Truth dilepton invariant mass is constrained to be within the range [1,40] GeV.
Observed and Expected upper cross-section limits for direct LH smuon scenarios.
Observed and Expected upper cross-section limits for direct LH smuon scenarios.
Observed and Expected upper cross-section limits for wino-bino scenarios, assuming $m(\tilde{\chi}_{2}^{0}) \times m(\tilde{\chi}_{1}^{0})>0$.
Observed and Expected upper cross-section limits for wino-bino scenarios, assuming $m(\tilde{\chi}_{2}^{0}) \times m(\tilde{\chi}_{1}^{0})>0$.
Observed and Expected upper cross-section limits for wino-bino scenarios, assuming $m(\tilde{\chi}_{2}^{0}) \times m(\tilde{\chi}_{1}^{0})>0$.
Observed and Expected upper cross-section limits for direct RH smuon scenarios.
Observed and Expected upper cross-section limits for direct RH smuon scenarios.
Observed and Expected upper cross-section limits for wino-bino scenarios, assuming $m(\tilde{\chi}_{2}^{0}) \times m(\tilde{\chi}_{1}^{0})<0$.
Observed and Expected upper cross-section limits for wino-bino scenarios, assuming $m(\tilde{\chi}_{2}^{0}) \times m(\tilde{\chi}_{1}^{0})<0$.
Observed and Expected upper cross-section limits for wino-bino scenarios, assuming $m(\tilde{\chi}_{2}^{0}) \times m(\tilde{\chi}_{1}^{0})<0$.
Observed and Expected upper cross-section limits for direct selectron scenarios.
Observed and Expected upper cross-section limits for direct selectron scenarios.
Observed and Expected upper cross-section limits for higgsino scenarios.
Observed and Expected upper cross-section limits for higgsino scenarios.
Observed and Expected upper cross-section limits for higgsino scenarios.
Observed and Expected upper cross-section limits for direct LH selectron scenarios.
Observed and Expected upper cross-section limits for direct LH selectron scenarios.
Observed and Expected upper cross-section limits for higgsino scenarios, assuming VBF production..
Observed and Expected upper cross-section limits for higgsino scenarios, assuming VBF production..
Observed and Expected upper cross-section limits for higgsino scenarios, assuming VBF production..
Observed and Expected upper cross-section limits for direct RH selectron scenarios.
Observed and Expected upper cross-section limits for direct RH selectron scenarios.
Observed and Expected upper cross-section limits for direct slepton scenarios.
Observed and Expected upper cross-section limits for direct slepton scenarios.
Observed and Expected upper cross-section limits for direct slepton scenarios.
Number of signal events in SR-E-1L1T for the (m($\tilde{\chi}_{2}^{0}$),m($\tilde{\chi}_{1}^{0}$)) = (155 GeV, 150 GeV) Higgsino signal model at different stages of selection before and after weighting events to correspond to 140/fb.
Number of signal events in SR-E-1L1T for the (m($\tilde{\chi}_{2}^{0}$),m($\tilde{\chi}_{1}^{0}$)) = (155 GeV, 150 GeV) Higgsino signal model at different stages of selection before and after weighting events to correspond to 140/fb.
Observed and Expected upper cross-section limits for direct LH slepton scenarios.
Observed and Expected upper cross-section limits for direct LH slepton scenarios.
Observed and Expected upper cross-section limits for direct LH slepton scenarios.
Number of signal events in SR-E-high for the (m($\tilde{\chi}_{2}^{0}$),m($\tilde{\chi}_{1}^{0}$)) = (155 GeV, 150 GeV) Higgsino signal model at different stages of selection before and after weighting events to correspond to 140/fb.
Number of signal events in SR-E-high for the (m($\tilde{\chi}_{2}^{0}$),m($\tilde{\chi}_{1}^{0}$)) = (155 GeV, 150 GeV) Higgsino signal model at different stages of selection before and after weighting events to correspond to 140/fb.
Observed and Expected upper cross-section limits for direct RH slepton scenarios.
Observed and Expected upper cross-section limits for direct RH slepton scenarios.
Observed and Expected upper cross-section limits for direct RH slepton scenarios.
Number of signal events in SR-E-low for the (m($\tilde{\chi}_{2}^{0}$),m($\tilde{\chi}_{1}^{0}$)) = (155 GeV, 150 GeV) Higgsino signal model at different stages of selection before and after weighting events to correspond to 140/fb.
Number of signal events in SR-E-low for the (m($\tilde{\chi}_{2}^{0}$),m($\tilde{\chi}_{1}^{0}$)) = (155 GeV, 150 GeV) Higgsino signal model at different stages of selection before and after weighting events to correspond to 140/fb.
Observed and Expected upper cross-section limits for direct smuon scenarios.
Observed and Expected upper cross-section limits for direct smuon scenarios.
Observed and Expected upper cross-section limits for direct smuon scenarios.
Number of signal events in SR-E-med for the (m($\tilde{\chi}_{2}^{0}$),m($\tilde{\chi}_{1}^{0}$)) = (155 GeV, 150 GeV) Higgsino signal model at different stages of selection before and after weighting events to correspond to 140/fb.
Number of signal events in SR-E-med for the (m($\tilde{\chi}_{2}^{0}$),m($\tilde{\chi}_{1}^{0}$)) = (155 GeV, 150 GeV) Higgsino signal model at different stages of selection before and after weighting events to correspond to 140/fb.
Observed and Expected upper cross-section limits for direct LH smuon scenarios.
Observed and Expected upper cross-section limits for direct LH smuon scenarios.
Observed and Expected upper cross-section limits for direct LH smuon scenarios.
Number of signal events in SR-S-high for the (m($\tilde{\ell}$),m($\tilde{\chi}_{1}^{0}$)) = (150 GeV, 140 GeV) Slepton signal model at different stages of selection before and after weighting events to correspond to 140/fb.
Number of signal events in SR-S-high for the (m($\tilde{\ell}$),m($\tilde{\chi}_{1}^{0}$)) = (150 GeV, 140 GeV) Slepton signal model at different stages of selection before and after weighting events to correspond to 140/fb.
Observed and Expected upper cross-section limits for direct RH smuon scenarios.
Observed and Expected upper cross-section limits for direct RH smuon scenarios.
Observed and Expected upper cross-section limits for direct RH smuon scenarios.
Number of signal events in SR-S-low for the (m($\tilde{\ell}$),m($\tilde{\chi}_{1}^{0}$)) = (150 GeV, 140 GeV) Slepton signal model at different stages of selection before and after weighting events to correspond to 140/fb.
Number of signal events in SR-S-low for the (m($\tilde{\ell}$),m($\tilde{\chi}_{1}^{0}$)) = (150 GeV, 140 GeV) Slepton signal model at different stages of selection before and after weighting events to correspond to 140/fb.
Observed and Expected upper cross-section limits for direct selectron scenarios.
Observed and Expected upper cross-section limits for direct selectron scenarios.
Observed and Expected upper cross-section limits for direct selectron scenarios.
Number of signal events in SR-VBF for the (m($\tilde{\chi}_{2}^{0}$),m($\tilde{\chi}_{1}^{0}$)) = (100 GeV, 95 GeV) Higgsino signal model at different stages of selection before and after weighting events to correspond to 140/fb.
Number of signal events in SR-VBF for the (m($\tilde{\chi}_{2}^{0}$),m($\tilde{\chi}_{1}^{0}$)) = (100 GeV, 95 GeV) Higgsino signal model at different stages of selection before and after weighting events to correspond to 140/fb.
Observed and Expected upper cross-section limits for direct LH selectron scenarios.
Observed and Expected upper cross-section limits for direct LH selectron scenarios.
Observed and Expected upper cross-section limits for direct LH selectron scenarios.
Observed and Expected upper cross-section limits for direct RH selectron scenarios.
Observed and Expected upper cross-section limits for direct RH selectron scenarios.
Observed and Expected upper cross-section limits for direct RH selectron scenarios.
Number of signal events in SR-E-1L1T for the (m($\tilde{\chi}_{2}^{0}$),m($\tilde{\chi}_{1}^{0}$)) = (155 GeV, 150 GeV) Higgsino signal model at different stages of selection before and after weighting events to correspond to 140/fb.
Number of signal events in SR-E-1L1T for the (m($\tilde{\chi}_{2}^{0}$),m($\tilde{\chi}_{1}^{0}$)) = (155 GeV, 150 GeV) Higgsino signal model at different stages of selection before and after weighting events to correspond to 140/fb.
Number of signal events in SR-E-1L1T for the (m($\tilde{\chi}_{2}^{0}$),m($\tilde{\chi}_{1}^{0}$)) = (155 GeV, 150 GeV) Higgsino signal model at different stages of selection before and after weighting events to correspond to 140/fb.
Number of signal events in SR-E-high for the (m($\tilde{\chi}_{2}^{0}$),m($\tilde{\chi}_{1}^{0}$)) = (155 GeV, 150 GeV) Higgsino signal model at different stages of selection before and after weighting events to correspond to 140/fb.
Number of signal events in SR-E-high for the (m($\tilde{\chi}_{2}^{0}$),m($\tilde{\chi}_{1}^{0}$)) = (155 GeV, 150 GeV) Higgsino signal model at different stages of selection before and after weighting events to correspond to 140/fb.
Number of signal events in SR-E-high for the (m($\tilde{\chi}_{2}^{0}$),m($\tilde{\chi}_{1}^{0}$)) = (155 GeV, 150 GeV) Higgsino signal model at different stages of selection before and after weighting events to correspond to 140/fb.
Number of signal events in SR-E-low for the (m($\tilde{\chi}_{2}^{0}$),m($\tilde{\chi}_{1}^{0}$)) = (155 GeV, 150 GeV) Higgsino signal model at different stages of selection before and after weighting events to correspond to 140/fb.
Number of signal events in SR-E-low for the (m($\tilde{\chi}_{2}^{0}$),m($\tilde{\chi}_{1}^{0}$)) = (155 GeV, 150 GeV) Higgsino signal model at different stages of selection before and after weighting events to correspond to 140/fb.
Number of signal events in SR-E-low for the (m($\tilde{\chi}_{2}^{0}$),m($\tilde{\chi}_{1}^{0}$)) = (155 GeV, 150 GeV) Higgsino signal model at different stages of selection before and after weighting events to correspond to 140/fb.
Number of signal events in SR-E-med for the (m($\tilde{\chi}_{2}^{0}$),m($\tilde{\chi}_{1}^{0}$)) = (155 GeV, 150 GeV) Higgsino signal model at different stages of selection before and after weighting events to correspond to 140/fb.
Number of signal events in SR-E-med for the (m($\tilde{\chi}_{2}^{0}$),m($\tilde{\chi}_{1}^{0}$)) = (155 GeV, 150 GeV) Higgsino signal model at different stages of selection before and after weighting events to correspond to 140/fb.
Number of signal events in SR-E-med for the (m($\tilde{\chi}_{2}^{0}$),m($\tilde{\chi}_{1}^{0}$)) = (155 GeV, 150 GeV) Higgsino signal model at different stages of selection before and after weighting events to correspond to 140/fb.
Number of signal events in SR-S-high for the (m($\tilde{\ell}$),m($\tilde{\chi}_{1}^{0}$)) = (150 GeV, 140 GeV) Slepton signal model at different stages of selection before and after weighting events to correspond to 140/fb.
Number of signal events in SR-S-high for the (m($\tilde{\ell}$),m($\tilde{\chi}_{1}^{0}$)) = (150 GeV, 140 GeV) Slepton signal model at different stages of selection before and after weighting events to correspond to 140/fb.
Number of signal events in SR-S-high for the (m($\tilde{\ell}$),m($\tilde{\chi}_{1}^{0}$)) = (150 GeV, 140 GeV) Slepton signal model at different stages of selection before and after weighting events to correspond to 140/fb.
Number of signal events in SR-S-low for the (m($\tilde{\ell}$),m($\tilde{\chi}_{1}^{0}$)) = (150 GeV, 140 GeV) Slepton signal model at different stages of selection before and after weighting events to correspond to 140/fb.
Number of signal events in SR-S-low for the (m($\tilde{\ell}$),m($\tilde{\chi}_{1}^{0}$)) = (150 GeV, 140 GeV) Slepton signal model at different stages of selection before and after weighting events to correspond to 140/fb.
Number of signal events in SR-S-low for the (m($\tilde{\ell}$),m($\tilde{\chi}_{1}^{0}$)) = (150 GeV, 140 GeV) Slepton signal model at different stages of selection before and after weighting events to correspond to 140/fb.
Number of signal events in SR-VBF for the (m($\tilde{\chi}_{2}^{0}$),m($\tilde{\chi}_{1}^{0}$)) = (100 GeV, 95 GeV) Higgsino signal model at different stages of selection before and after weighting events to correspond to 140/fb.
Number of signal events in SR-VBF for the (m($\tilde{\chi}_{2}^{0}$),m($\tilde{\chi}_{1}^{0}$)) = (100 GeV, 95 GeV) Higgsino signal model at different stages of selection before and after weighting events to correspond to 140/fb.
Number of signal events in SR-VBF for the (m($\tilde{\chi}_{2}^{0}$),m($\tilde{\chi}_{1}^{0}$)) = (100 GeV, 95 GeV) Higgsino signal model at different stages of selection before and after weighting events to correspond to 140/fb.
When you search on a word, e.g. 'collisions', we will automatically search across everything we store about a record. But, sometimes you may wish to be more specific. Here we show you how.
Guidance and examples on the query string syntax can be found in the Elasticsearch documentation.
About HEPData Submitting to HEPData HEPData File Formats HEPData Coordinators HEPData Terms of Use HEPData Cookie Policy
Status Email Forum Twitter GitHub
Copyright ~1975-Present, HEPData | Powered by Invenio, funded by STFC, hosted and originally developed at CERN, supported and further developed at IPPP Durham.